{"id":"https://openalex.org/W3127945445","doi":"https://doi.org/10.1109/icoin50884.2021.9333901","title":"Energy Balancing and Source Node Privacy Protection in Event Monitoring Wireless Networks","display_name":"Energy Balancing and Source Node Privacy Protection in Event Monitoring Wireless Networks","publication_year":2021,"publication_date":"2021-01-13","ids":{"openalex":"https://openalex.org/W3127945445","doi":"https://doi.org/10.1109/icoin50884.2021.9333901","mag":"3127945445"},"language":"en","primary_location":{"id":"doi:10.1109/icoin50884.2021.9333901","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icoin50884.2021.9333901","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 International Conference on Information Networking (ICOIN)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091498185","display_name":"Lilian C. Mutalemwa","orcid":"https://orcid.org/0000-0003-4342-5562"},"institutions":[{"id":"https://openalex.org/I152238500","display_name":"Chosun University","ror":"https://ror.org/01zt9a375","country_code":"KR","type":"education","lineage":["https://openalex.org/I152238500"]}],"countries":["KR"],"is_corresponding":true,"raw_author_name":"Lilian C. Mutalemwa","raw_affiliation_strings":["Chosun University, Gwangju, South Korea"],"affiliations":[{"raw_affiliation_string":"Chosun University, Gwangju, South Korea","institution_ids":["https://openalex.org/I152238500"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5009170109","display_name":"Seokjoo Shin","orcid":"https://orcid.org/0000-0003-2092-1336"},"institutions":[{"id":"https://openalex.org/I152238500","display_name":"Chosun University","ror":"https://ror.org/01zt9a375","country_code":"KR","type":"education","lineage":["https://openalex.org/I152238500"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Seokjoo Shin","raw_affiliation_strings":["Chosun University, Gwangju, South Korea"],"affiliations":[{"raw_affiliation_string":"Chosun University, Gwangju, South Korea","institution_ids":["https://openalex.org/I152238500"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5091498185"],"corresponding_institution_ids":["https://openalex.org/I152238500"],"apc_list":null,"apc_paid":null,"fwci":0.16,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.48537192,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"19","issue":null,"first_page":"792","last_page":"797"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11498","display_name":"Security in Wireless Sensor Networks","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7343720197677612},{"id":"https://openalex.org/keywords/protocol","display_name":"Protocol (science)","score":0.6888560652732849},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5985015034675598},{"id":"https://openalex.org/keywords/routing-protocol","display_name":"Routing protocol","score":0.5870701670646667},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5843682289123535},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5382622480392456},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.494083434343338},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4940193295478821},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3363853394985199},{"id":"https://openalex.org/keywords/routing","display_name":"Routing (electronic design automation)","score":0.30333346128463745},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13605132699012756}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7343720197677612},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.6888560652732849},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5985015034675598},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.5870701670646667},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5843682289123535},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5382622480392456},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.494083434343338},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4940193295478821},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3363853394985199},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.30333346128463745},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13605132699012756},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icoin50884.2021.9333901","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icoin50884.2021.9333901","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 International Conference on Information Networking (ICOIN)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1966725398","https://openalex.org/W2050409719","https://openalex.org/W2102953261","https://openalex.org/W2245125533","https://openalex.org/W2754393457","https://openalex.org/W2804037537","https://openalex.org/W2883150861","https://openalex.org/W2886503233","https://openalex.org/W2896039510","https://openalex.org/W2898359313","https://openalex.org/W2942806102","https://openalex.org/W2942986951","https://openalex.org/W2961676902","https://openalex.org/W2973047729","https://openalex.org/W2977074976","https://openalex.org/W2999640470","https://openalex.org/W3000993635","https://openalex.org/W3012311983","https://openalex.org/W3018624961","https://openalex.org/W6775088086"],"related_works":["https://openalex.org/W1975451135","https://openalex.org/W2989915292","https://openalex.org/W2890570089","https://openalex.org/W2073793005","https://openalex.org/W3148968234","https://openalex.org/W145760256","https://openalex.org/W2028086369","https://openalex.org/W2141581111","https://openalex.org/W2129477171","https://openalex.org/W4376136918"],"abstract_inverted_index":{"It":[0],"is":[1,21,98,111],"important":[2],"to":[3,15,23,55,76],"ensure":[4],"source":[5],"location":[6],"privacy":[7],"(SLP)":[8],"protection":[9,58,86],"in":[10,100,113],"safety-critical":[11],"monitoring":[12,102,115],"applications.":[13],"Also,":[14],"achieve":[16,56],"effective":[17],"long-term":[18,101,114],"monitoring,":[19],"it":[20],"essential":[22],"design":[24],"SLP":[25,57,85],"protocols":[26,79],"with":[27,41,59],"high":[28,82],"energy":[29,32,60,63],"efficiency":[30,61],"and":[31,62],"balancing.":[33,64],"Therefore,":[34],"this":[35],"study":[36],"proposes":[37],"a":[38],"new":[39],"phantom":[40],"angle":[42],"(PwA)":[43],"protocol.":[44],"The":[45,91,104],"PwA":[46,70,96,109],"protocol":[47,71,97,110],"employs":[48],"dynamic":[49],"routing":[50],"paths":[51],"which":[52],"are":[53],"designed":[54],"Analysis":[65],"results":[66,92,105],"reveal":[67],"that":[68,94,107],"the":[69,95,108],"exhibits":[72],"superior":[73],"performance":[74],"features":[75],"outperform":[77],"existing":[78],"by":[80],"achieving":[81],"levels":[83],"of":[84],"for":[87],"time":[88],"petime":[89],"periods.":[90],"confirm":[93,106],"practical":[99,112],"systems.riods.":[103],"systems.":[116]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":1}],"updated_date":"2026-04-02T15:55:50.835912","created_date":"2025-10-10T00:00:00"}
