{"id":"https://openalex.org/W2798436738","doi":"https://doi.org/10.1109/icit.2018.8352267","title":"Frequency control of MMC-HVDC based on active and reactive power decoupling","display_name":"Frequency control of MMC-HVDC based on active and reactive power decoupling","publication_year":2018,"publication_date":"2018-02-01","ids":{"openalex":"https://openalex.org/W2798436738","doi":"https://doi.org/10.1109/icit.2018.8352267","mag":"2798436738"},"language":"en","primary_location":{"id":"doi:10.1109/icit.2018.8352267","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2018.8352267","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5011575000","display_name":"Alvaro Carreno","orcid":"https://orcid.org/0000-0002-9545-662X"},"institutions":[{"id":"https://openalex.org/I75778554","display_name":"Federico Santa Mar\u00eda Technical University","ror":"https://ror.org/05510vn56","country_code":"CL","type":"education","lineage":["https://openalex.org/I75778554"]}],"countries":["CL"],"is_corresponding":true,"raw_author_name":"Alvaro Carreno","raw_affiliation_strings":["Department of Electronics, Universidad Tecnica Federico Santa Maria, Valparaiso, Chile"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Universidad Tecnica Federico Santa Maria, Valparaiso, Chile","institution_ids":["https://openalex.org/I75778554"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046484546","display_name":"Marcelo A. P\u00e9rez","orcid":"https://orcid.org/0000-0003-4166-448X"},"institutions":[{"id":"https://openalex.org/I75778554","display_name":"Federico Santa Mar\u00eda Technical University","ror":"https://ror.org/05510vn56","country_code":"CL","type":"education","lineage":["https://openalex.org/I75778554"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Marcelo A. Perez","raw_affiliation_strings":["Department of Electronics, Universidad Tecnica Federico Santa Maria, Valparaiso, Chile"],"affiliations":[{"raw_affiliation_string":"Department of Electronics, Universidad Tecnica Federico Santa Maria, Valparaiso, Chile","institution_ids":["https://openalex.org/I75778554"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5017074731","display_name":"Jos\u00e9 Espinoza","orcid":"https://orcid.org/0000-0001-6648-7518"},"institutions":[{"id":"https://openalex.org/I172787465","display_name":"University of Concepci\u00f3n","ror":"https://ror.org/0460jpj73","country_code":"CL","type":"education","lineage":["https://openalex.org/I172787465"]}],"countries":["CL"],"is_corresponding":false,"raw_author_name":"Jose Espinoza","raw_affiliation_strings":["Department of Electrical Engineering, Universidad de Concepcion, Concepcion, Chile"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Universidad de Concepcion, Concepcion, Chile","institution_ids":["https://openalex.org/I172787465"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5011575000"],"corresponding_institution_ids":["https://openalex.org/I75778554"],"apc_list":null,"apc_paid":null,"fwci":0.1288,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.45601791,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"7","issue":null,"first_page":"724","last_page":"729"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9764999747276306,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.8186432123184204},{"id":"https://openalex.org/keywords/decoupling","display_name":"Decoupling (probability)","score":0.7398690581321716},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6910609602928162},{"id":"https://openalex.org/keywords/frequency-deviation","display_name":"Frequency deviation","score":0.6072622537612915},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.5927435159683228},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.5003094673156738},{"id":"https://openalex.org/keywords/volt-ampere-reactive","display_name":"Volt-ampere reactive","score":0.4868723452091217},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.4866679310798645},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4755384922027588},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4678628742694855},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.4544050097465515},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4428233206272125},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.42845362424850464},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.42304179072380066},{"id":"https://openalex.org/keywords/modular-design","display_name":"Modular design","score":0.4184820055961609},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.41727614402770996},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.3899371325969696},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.37096506357192993},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3254629969596863},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2308715283870697},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.19146713614463806},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17892897129058838},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10855191946029663},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.08664888143539429}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8186432123184204},{"id":"https://openalex.org/C205606062","wikidata":"https://www.wikidata.org/wiki/Q5249645","display_name":"Decoupling (probability)","level":2,"score":0.7398690581321716},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6910609602928162},{"id":"https://openalex.org/C123919525","wikidata":"https://www.wikidata.org/wiki/Q761942","display_name":"Frequency deviation","level":3,"score":0.6072622537612915},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5927435159683228},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.5003094673156738},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.4868723452091217},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4866679310798645},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4755384922027588},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4678628742694855},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.4544050097465515},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4428233206272125},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.42845362424850464},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.42304179072380066},{"id":"https://openalex.org/C101468663","wikidata":"https://www.wikidata.org/wiki/Q1620158","display_name":"Modular design","level":2,"score":0.4184820055961609},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.41727614402770996},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.3899371325969696},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.37096506357192993},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3254629969596863},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2308715283870697},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.19146713614463806},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17892897129058838},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10855191946029663},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.08664888143539429},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icit.2018.8352267","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2018.8352267","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1552592618","https://openalex.org/W1763243278","https://openalex.org/W1980362338","https://openalex.org/W2040578945","https://openalex.org/W2042005013","https://openalex.org/W2068169602","https://openalex.org/W2113172270","https://openalex.org/W2328229040","https://openalex.org/W2343661562","https://openalex.org/W2498570208","https://openalex.org/W2556474417","https://openalex.org/W2613392942","https://openalex.org/W2797591428","https://openalex.org/W6729983957"],"related_works":["https://openalex.org/W2892695466","https://openalex.org/W3127790372","https://openalex.org/W2382782532","https://openalex.org/W3168778428","https://openalex.org/W4391237069","https://openalex.org/W2779431316","https://openalex.org/W2369535890","https://openalex.org/W2376722172","https://openalex.org/W2360369074","https://openalex.org/W3163094968"],"abstract_inverted_index":{"High":[0],"voltage":[1],"DC":[2],"systems":[3],"based":[4],"on":[5],"modular":[6],"multi-level":[7],"converters":[8],"have":[9,40],"been":[10],"received":[11],"increased":[12],"attention":[13],"due":[14],"to":[15,32,63,96],"the":[16,23,27,33,36,45,55,58,65,74,80,102],"high":[17],"power":[18,25,62,76,95],"quality":[19],"they":[20],"provide.":[21],"When":[22],"rated":[24],"of":[26],"HVDC":[28],"station":[29,38],"is":[30],"similar":[31],"generating":[34],"units,":[35],"converter":[37],"can":[39],"an":[41],"important":[42],"role":[43],"in":[44,51,86],"frequency":[46,82,90,103],"regulation.":[47],"The":[48],"method":[49,85],"proposed":[50],"this":[52],"paper":[53],"uses":[54],"relation":[56],"between":[57],"active":[59,75,94],"and":[60,100],"reactive":[61],"estimate":[64],"load":[66,98],"changes":[67,99],"adding":[68],"a":[69,89,108],"feed-forward":[70],"compensation":[71],"term":[72],"for":[73],"reference":[77,106],"thus":[78],"reducing":[79],"dynamical":[81],"deviation.":[83,111],"This":[84],"combination":[87],"with":[88,107],"PI":[91],"controller,":[92],"delivers":[93],"compensate":[97],"keeps":[101],"at":[104],"its":[105],"very":[109],"small":[110]},"counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}