{"id":"https://openalex.org/W2612463465","doi":"https://doi.org/10.1109/icit.2017.7913269","title":"Flux coupling type superconducting fault current limiter in a transmission and wind energy system","display_name":"Flux coupling type superconducting fault current limiter in a transmission and wind energy system","publication_year":2017,"publication_date":"2017-03-01","ids":{"openalex":"https://openalex.org/W2612463465","doi":"https://doi.org/10.1109/icit.2017.7913269","mag":"2612463465"},"language":"en","primary_location":{"id":"doi:10.1109/icit.2017.7913269","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2017.7913269","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5090779747","display_name":"Maloth Naresh","orcid":null},"institutions":[{"id":"https://openalex.org/I152869788","display_name":"Motilal Nehru National Institute of Technology","ror":"https://ror.org/04dp7tp96","country_code":"IN","type":"education","lineage":["https://openalex.org/I152869788"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Maloth Naresh","raw_affiliation_strings":["Electrical Engineering Department, MNNIT, Allahabad, India"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, MNNIT, Allahabad, India","institution_ids":["https://openalex.org/I152869788"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100753454","display_name":"Ramesh Kumar Tripathi","orcid":"https://orcid.org/0000-0003-0030-4461"},"institutions":[{"id":"https://openalex.org/I152869788","display_name":"Motilal Nehru National Institute of Technology","ror":"https://ror.org/04dp7tp96","country_code":"IN","type":"education","lineage":["https://openalex.org/I152869788"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ramesh Kumar Tripathi","raw_affiliation_strings":["Electrical Engineering Department, MNNIT, Allahabad, India"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering Department, MNNIT, Allahabad, India","institution_ids":["https://openalex.org/I152869788"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5090779747"],"corresponding_institution_ids":["https://openalex.org/I152869788"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.04055467,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"429","last_page":"433"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9829000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-current-limiter","display_name":"Fault current limiter","score":0.8270159959793091},{"id":"https://openalex.org/keywords/current-limiting","display_name":"Current limiting","score":0.7286990880966187},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6417460441589355},{"id":"https://openalex.org/keywords/limiter","display_name":"Limiter","score":0.5813534259796143},{"id":"https://openalex.org/keywords/coupling","display_name":"Coupling (piping)","score":0.49461767077445984},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.4881158769130707},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.48796314001083374},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4361388683319092},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.424148291349411},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3281073570251465},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27517271041870117},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.219954252243042},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.21019485592842102},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.14836585521697998},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.08869332075119019}],"concepts":[{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.8270159959793091},{"id":"https://openalex.org/C204106720","wikidata":"https://www.wikidata.org/wiki/Q15856134","display_name":"Current limiting","level":3,"score":0.7286990880966187},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6417460441589355},{"id":"https://openalex.org/C45011657","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiter","level":2,"score":0.5813534259796143},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.49461767077445984},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.4881158769130707},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.48796314001083374},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4361388683319092},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.424148291349411},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3281073570251465},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27517271041870117},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.219954252243042},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.21019485592842102},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14836585521697998},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.08869332075119019},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icit.2017.7913269","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icit.2017.7913269","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Industrial Technology (ICIT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":17,"referenced_works":["https://openalex.org/W1824162604","https://openalex.org/W1970382661","https://openalex.org/W1982315519","https://openalex.org/W2014030617","https://openalex.org/W2061073362","https://openalex.org/W2089965706","https://openalex.org/W2097340349","https://openalex.org/W2119777968","https://openalex.org/W2123002573","https://openalex.org/W2130897576","https://openalex.org/W2132603825","https://openalex.org/W2134936199","https://openalex.org/W2137279557","https://openalex.org/W2148696731","https://openalex.org/W2331395393","https://openalex.org/W2413499958","https://openalex.org/W6702127773"],"related_works":["https://openalex.org/W3205461242","https://openalex.org/W2156592284","https://openalex.org/W2081461087","https://openalex.org/W2120692498","https://openalex.org/W2126473043","https://openalex.org/W2393419321","https://openalex.org/W3094667972","https://openalex.org/W2619699170","https://openalex.org/W3003057893","https://openalex.org/W2160511799"],"abstract_inverted_index":{"Now":[0],"a":[1,23],"days,":[2],"Superconducting":[3,69],"fault":[4,16,33,50,70],"current":[5,17,34,51,59,71],"limiter":[6,18,72],"(SFCL)":[7,73],"is":[8,28],"emerged":[9],"as":[10,75],"one":[11],"of":[12,58],"the":[13,32],"most":[14],"accomplished":[15],"(FCL)":[19],"In":[20],"this":[21],"Paper,":[22],"flux":[24,45],"coupling":[25],"type":[26],"SFCL":[27],"designed":[29],"for":[30,98],"limiting":[31],"in":[35,56,95],"isolated":[36,99],"wind":[37,100],"turbine":[38],"generation":[39],"system.":[40,102],"The":[41,85],"proposed":[42],"Resistive":[43],"and":[44,63,65,89],"Coupling":[46],"based":[47],"super":[48],"conducting":[49],"limiters":[52],"have":[53],"improved":[54],"performance":[55],"terms":[57],"limitation,":[60],"higher":[61],"reliability":[62],"lifetime":[64],"reduced":[66],"material":[67],"requirement.":[68],"appears":[74],"an":[76],"excellent":[77],"FCL":[78],"which":[79],"tends":[80],"to":[81],"satisfy":[82],"above":[83],"features.":[84],"whole":[86],"research":[87],"work":[88],"analysis":[90],"has":[91],"been":[92],"carried":[93],"out":[94],"MATLAB/SIMULINK":[96],"environment":[97],"energy":[101]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
