{"id":"https://openalex.org/W2947569847","doi":"https://doi.org/10.1109/iciinfs.2018.8721427","title":"IEC 61850 Communication Assisted Synchronization Strategy for Microgrids","display_name":"IEC 61850 Communication Assisted Synchronization Strategy for Microgrids","publication_year":2018,"publication_date":"2018-12-01","ids":{"openalex":"https://openalex.org/W2947569847","doi":"https://doi.org/10.1109/iciinfs.2018.8721427","mag":"2947569847"},"language":"en","primary_location":{"id":"doi:10.1109/iciinfs.2018.8721427","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iciinfs.2018.8721427","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 13th International Conference on Industrial and Information Systems (ICIIS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063267580","display_name":"Mohd Asim Aftab","orcid":"https://orcid.org/0000-0002-1546-8349"},"institutions":[{"id":"https://openalex.org/I59475050","display_name":"Jamia Millia Islamia","ror":"https://ror.org/00pnhhv55","country_code":"IN","type":"education","lineage":["https://openalex.org/I59475050"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Mohd Asim Aftab","raw_affiliation_strings":["Electrical Engineering, Jamia Millia Islamia, New Delhi, India"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Jamia Millia Islamia, New Delhi, India","institution_ids":["https://openalex.org/I59475050"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025961867","display_name":"S. M. Suhail Hussain","orcid":"https://orcid.org/0000-0002-7779-8140"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S.M. Suhail Hussain","raw_affiliation_strings":["Fukushima Renewable Energy Institute, AIST (FREA), Koriyama, Japan"],"affiliations":[{"raw_affiliation_string":"Fukushima Renewable Energy Institute, AIST (FREA), Koriyama, Japan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100694273","display_name":"Vivek Kumar","orcid":"https://orcid.org/0000-0001-9285-2857"},"institutions":[{"id":"https://openalex.org/I59475050","display_name":"Jamia Millia Islamia","ror":"https://ror.org/00pnhhv55","country_code":"IN","type":"education","lineage":["https://openalex.org/I59475050"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Vivek Kumar","raw_affiliation_strings":["Electrical Engineering, Jamia Millia Islamia, New Delhi, India"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Jamia Millia Islamia, New Delhi, India","institution_ids":["https://openalex.org/I59475050"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026767724","display_name":"Taha Selim Ustun","orcid":"https://orcid.org/0000-0002-2413-8421"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Taha Selim Ustun","raw_affiliation_strings":["Fukushima Renewable Energy Institute, AIST (FREA), Koriyama, Japan"],"affiliations":[{"raw_affiliation_string":"Fukushima Renewable Energy Institute, AIST (FREA), Koriyama, Japan","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019323002","display_name":"Ikbal Ali","orcid":"https://orcid.org/0000-0001-9630-8007"},"institutions":[{"id":"https://openalex.org/I59475050","display_name":"Jamia Millia Islamia","ror":"https://ror.org/00pnhhv55","country_code":"IN","type":"education","lineage":["https://openalex.org/I59475050"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ikbal Ali","raw_affiliation_strings":["Electrical Engineering, Jamia Millia Islamia, New Delhi, India"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering, Jamia Millia Islamia, New Delhi, India","institution_ids":["https://openalex.org/I59475050"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5063267580"],"corresponding_institution_ids":["https://openalex.org/I59475050"],"apc_list":null,"apc_paid":null,"fwci":1.8393,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.86796014,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"401","last_page":"406"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9780280590057373},{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.9483014345169067},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.7932357788085938},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.7346243858337402},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4662180542945862},{"id":"https://openalex.org/keywords/phasor-measurement-unit","display_name":"Phasor measurement unit","score":0.45909935235977173},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4583307206630707},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.42965370416641235},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.42108798027038574},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.377867728471756},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3738030791282654},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37125349044799805},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3322409987449646},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3218999207019806},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.2704002857208252},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.26263514161109924},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.25526952743530273},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.15712347626686096},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10153713822364807},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07601821422576904}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9780280590057373},{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.9483014345169067},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.7932357788085938},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.7346243858337402},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4662180542945862},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.45909935235977173},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4583307206630707},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.42965370416641235},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.42108798027038574},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.377867728471756},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3738030791282654},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37125349044799805},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3322409987449646},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3218999207019806},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.2704002857208252},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.26263514161109924},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.25526952743530273},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.15712347626686096},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10153713822364807},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07601821422576904},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iciinfs.2018.8721427","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iciinfs.2018.8721427","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE 13th International Conference on Industrial and Information Systems (ICIIS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1964728279","https://openalex.org/W1980394451","https://openalex.org/W2050388675","https://openalex.org/W2108882684","https://openalex.org/W2466448847","https://openalex.org/W2510522738","https://openalex.org/W2537708162"],"related_works":["https://openalex.org/W2377759402","https://openalex.org/W2060186004","https://openalex.org/W2564500233","https://openalex.org/W2337841097","https://openalex.org/W2028471916","https://openalex.org/W1538400183","https://openalex.org/W2027377403","https://openalex.org/W2766771072","https://openalex.org/W2096980798","https://openalex.org/W2547260311"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"out":[3],"of":[4,7,17,22],"phase":[5,48,75,106],"re-closing":[6],"islanded":[8],"microgrid":[9,18,37,102],"with":[10,19,72],"utility":[11],"grid":[12],"is":[13,29,32,112],"considered.":[14,30],"Active":[15],"synchronization":[16,110],"the":[20,36,90,97,105],"help":[21],"synchrophasors":[23],"through":[24,114],"Phasor":[25],"Measurement":[26],"Units":[27],"(PMUs)":[28],"Synchronization":[31],"achieved":[33],"by":[34,41,52,86],"satisfying":[35],"reconnection":[38],"requirements":[39],"specified":[40],"IEEE":[42],"1547":[43],"std.":[44],"The":[45,56,74,109],"voltages":[46],"and":[47,60,70],"angles":[49],"are":[50,64,84],"measured":[51],"IEC":[53,68],"61850-90-5":[54,57],"PMUs.":[55],"PMU,":[58],"MGCC":[59,88],"DER":[61],"controller":[62],"communication":[63],"modeled":[65],"according":[66],"to":[67,95,103],"61850":[69],"implemented":[71],"UDP/IP.":[73],"angle":[76,107],"differences":[77],"at":[78],"PCC,":[79],"if":[80],"any":[81],"before":[82],"synchronization,":[83],"eliminated":[85],"MGCC.":[87],"coordinates":[89],"DERs,":[91],"as":[92],"per":[93],"constraints,":[94],"produce":[96],"required":[98],"active":[99],"power":[100],"in":[101],"eliminate":[104],"difference.":[108],"process":[111],"demonstrated":[113],"simulations.":[115]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":4}],"updated_date":"2025-11-25T21:42:39.735039","created_date":"2025-10-10T00:00:00"}
