{"id":"https://openalex.org/W4223649043","doi":"https://doi.org/10.1109/iceic54506.2022.9748853","title":"Method of Estimating Positions for Multiple People in Non-Contact Vital Signs Monitoring Systems","display_name":"Method of Estimating Positions for Multiple People in Non-Contact Vital Signs Monitoring Systems","publication_year":2022,"publication_date":"2022-02-06","ids":{"openalex":"https://openalex.org/W4223649043","doi":"https://doi.org/10.1109/iceic54506.2022.9748853"},"language":"en","primary_location":{"id":"doi:10.1109/iceic54506.2022.9748853","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceic54506.2022.9748853","pdf_url":null,"source":{"id":"https://openalex.org/S4363608213","display_name":"2022 International Conference on Electronics, Information, and Communication (ICEIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 International Conference on Electronics, Information, and Communication (ICEIC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046714834","display_name":"Masaya Kashiwagi","orcid":null},"institutions":[{"id":"https://openalex.org/I139159150","display_name":"University of Shiga Prefecture","ror":"https://ror.org/02dvjfw95","country_code":"JP","type":"education","lineage":["https://openalex.org/I139159150"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Masaya Kashiwagi","raw_affiliation_strings":["The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533"],"affiliations":[{"raw_affiliation_string":"The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533","institution_ids":["https://openalex.org/I139159150"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082242690","display_name":"Toshiyuki Inoue","orcid":"https://orcid.org/0000-0002-6621-1412"},"institutions":[{"id":"https://openalex.org/I139159150","display_name":"University of Shiga Prefecture","ror":"https://ror.org/02dvjfw95","country_code":"JP","type":"education","lineage":["https://openalex.org/I139159150"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Toshiyuki Inoue","raw_affiliation_strings":["The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533"],"affiliations":[{"raw_affiliation_string":"The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533","institution_ids":["https://openalex.org/I139159150"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073833041","display_name":"Masanao Okamoto","orcid":null},"institutions":[{"id":"https://openalex.org/I139159150","display_name":"University of Shiga Prefecture","ror":"https://ror.org/02dvjfw95","country_code":"JP","type":"education","lineage":["https://openalex.org/I139159150"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Masanao Okamoto","raw_affiliation_strings":["The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533"],"affiliations":[{"raw_affiliation_string":"The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533","institution_ids":["https://openalex.org/I139159150"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038761727","display_name":"Akira Tsuchiya","orcid":"https://orcid.org/0000-0002-3299-9328"},"institutions":[{"id":"https://openalex.org/I139159150","display_name":"University of Shiga Prefecture","ror":"https://ror.org/02dvjfw95","country_code":"JP","type":"education","lineage":["https://openalex.org/I139159150"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Akira Tsuchiya","raw_affiliation_strings":["The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533"],"affiliations":[{"raw_affiliation_string":"The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533","institution_ids":["https://openalex.org/I139159150"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5022381888","display_name":"Keiji Kishine","orcid":"https://orcid.org/0000-0003-3213-6650"},"institutions":[{"id":"https://openalex.org/I139159150","display_name":"University of Shiga Prefecture","ror":"https://ror.org/02dvjfw95","country_code":"JP","type":"education","lineage":["https://openalex.org/I139159150"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Keiji Kishine","raw_affiliation_strings":["The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533"],"affiliations":[{"raw_affiliation_string":"The University of Shiga Prefecture,Department of Electronic Systems Engineering,Shiga,Japan,522-8533","institution_ids":["https://openalex.org/I139159150"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5046714834"],"corresponding_institution_ids":["https://openalex.org/I139159150"],"apc_list":null,"apc_paid":null,"fwci":0.3206,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.39302957,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11707","display_name":"Gaze Tracking and Assistive Technology","score":0.9732999801635742,"subfield":{"id":"https://openalex.org/subfields/1709","display_name":"Human-Computer Interaction"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10326","display_name":"Indoor and Outdoor Localization Technologies","score":0.9664000272750854,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vital-signs","display_name":"Vital signs","score":0.9797090291976929},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5544188618659973},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.49533072113990784},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.49006974697113037},{"id":"https://openalex.org/keywords/respiratory-rate","display_name":"Respiratory rate","score":0.4822443425655365},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.3603046238422394},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.32394397258758545},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.18359950184822083},{"id":"https://openalex.org/keywords/nursing","display_name":"Nursing","score":0.17066261172294617}],"concepts":[{"id":"https://openalex.org/C2776890885","wikidata":"https://www.wikidata.org/wiki/Q1067560","display_name":"Vital signs","level":2,"score":0.9797090291976929},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5544188618659973},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.49533072113990784},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.49006974697113037},{"id":"https://openalex.org/C8213797","wikidata":"https://www.wikidata.org/wiki/Q754250","display_name":"Respiratory rate","level":4,"score":0.4822443425655365},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.3603046238422394},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.32394397258758545},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.18359950184822083},{"id":"https://openalex.org/C159110408","wikidata":"https://www.wikidata.org/wiki/Q121176","display_name":"Nursing","level":1,"score":0.17066261172294617},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iceic54506.2022.9748853","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceic54506.2022.9748853","pdf_url":null,"source":{"id":"https://openalex.org/S4363608213","display_name":"2022 International Conference on Electronics, Information, and Communication (ICEIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 International Conference on Electronics, Information, and Communication (ICEIC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Decent work and economic growth","id":"https://metadata.un.org/sdg/8","score":0.7099999785423279}],"awards":[{"id":"https://openalex.org/G4879400530","display_name":null,"funder_award_id":"JP19K14998","funder_id":"https://openalex.org/F4320320212","funder_display_name":"Japan Society for the Promotion of Science London"}],"funders":[{"id":"https://openalex.org/F4320320212","display_name":"Japan Society for the Promotion of Science London","ror":"https://ror.org/02m7axw05"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1981919460","https://openalex.org/W2113224262","https://openalex.org/W2129042353","https://openalex.org/W2135461721","https://openalex.org/W2606438808","https://openalex.org/W3133748831","https://openalex.org/W3164504725"],"related_works":["https://openalex.org/W2123587639","https://openalex.org/W2296621382","https://openalex.org/W4200157863","https://openalex.org/W3157359648","https://openalex.org/W2992252076","https://openalex.org/W2064560406","https://openalex.org/W3007661370","https://openalex.org/W2791489307","https://openalex.org/W4301172460","https://openalex.org/W3194512858"],"abstract_inverted_index":{"Vital":[0],"signs":[1,61],"monitoring":[2,62],"systems":[3],"have":[4],"been":[5],"studied":[6],"ea-gerly":[7],"for":[8,64,87],"reducing":[9],"labor":[10],"burden":[11],"in":[12,50,67],"nursing":[13,71],"facilities.":[14,72],"A":[15],"microwave":[16],"sensor":[17],"can":[18],"detect":[19],"vital":[20,60],"signs,":[21],"such":[22],"as":[23],"heart":[24],"rate":[25],"and":[26,42],"respiratory":[27],"rate,":[28],"without":[29],"any":[30],"contact":[31],"with":[32,82],"the":[33,37,51,68,80,88],"human":[34],"body.":[35],"However,":[36],"detection":[38],"area":[39],"is":[40,44],"narrow,":[41],"it":[43],"difficult":[45],"to":[46],"monitor":[47],"multiple":[48,65],"people":[49,66],"room.":[52],"In":[53],"this":[54],"paper,":[55],"we":[56,74],"propose":[57],"a":[58,76],"new":[59],"system":[63],"room":[69],"of":[70,78],"Also,":[73],"present":[75],"method":[77],"estimating":[79],"positions":[81],"non-contact":[83],"using":[84],"thermal":[85],"images":[86],"proposed":[89],"system.":[90]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
