{"id":"https://openalex.org/W2103486803","doi":"https://doi.org/10.1109/iceei.2011.6021818","title":"Transient analysis of 150 kV shunt reactor at Bulukumba Substation","display_name":"Transient analysis of 150 kV shunt reactor at Bulukumba Substation","publication_year":2011,"publication_date":"2011-07-01","ids":{"openalex":"https://openalex.org/W2103486803","doi":"https://doi.org/10.1109/iceei.2011.6021818","mag":"2103486803"},"language":"en","primary_location":{"id":"doi:10.1109/iceei.2011.6021818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082472361","display_name":"Ronald P. Hutahaean","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Ronald P. Hutahaean","raw_affiliation_strings":["PT PLN (Persero) AP2B Sistem Sulsel, Makassar, Indonesia","PT PLN (Persero) AP2B Sistem Sulsel, Jalan Hertasning Blok B, Makassar 90222, Indonesia"],"affiliations":[{"raw_affiliation_string":"PT PLN (Persero) AP2B Sistem Sulsel, Makassar, Indonesia","institution_ids":[]},{"raw_affiliation_string":"PT PLN (Persero) AP2B Sistem Sulsel, Jalan Hertasning Blok B, Makassar 90222, Indonesia","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079563319","display_name":"Gibson H.M. Sianipar","orcid":null},"institutions":[{"id":"https://openalex.org/I134635517","display_name":"Bandung Institute of Technology","ror":"https://ror.org/00apj8t60","country_code":"ID","type":"education","lineage":["https://openalex.org/I134635517"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Gibson Sianipar","raw_affiliation_strings":["School of Electrical and Informatics Engineering, Institut Teknologi Bandung, Bandung, West Java, Indonesia","School of Electrical and Informatics Engineering, Institut Teknologi Bandung, Jl. Ganesha 10, 40132, West Java, Indonesia"],"affiliations":[{"raw_affiliation_string":"School of Electrical and Informatics Engineering, Institut Teknologi Bandung, Bandung, West Java, Indonesia","institution_ids":["https://openalex.org/I134635517"]},{"raw_affiliation_string":"School of Electrical and Informatics Engineering, Institut Teknologi Bandung, Jl. Ganesha 10, 40132, West Java, Indonesia","institution_ids":["https://openalex.org/I134635517"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5082472361"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.13704572,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12077","display_name":"Vacuum and Plasma Arcs","score":0.9854999780654907,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9829999804496765,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inrush-current","display_name":"Inrush current","score":0.8540197610855103},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.8149471282958984},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.6894626617431641},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.6013087034225464},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5559080243110657},{"id":"https://openalex.org/keywords/transient-recovery-voltage","display_name":"Transient recovery voltage","score":0.5522093176841736},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.5296432971954346},{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.5183454751968384},{"id":"https://openalex.org/keywords/shunt","display_name":"Shunt (medical)","score":0.5180449485778809},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.47767454385757446},{"id":"https://openalex.org/keywords/emtp","display_name":"Emtp","score":0.4744347631931305},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4735535681247711},{"id":"https://openalex.org/keywords/inductor","display_name":"Inductor","score":0.46019673347473145},{"id":"https://openalex.org/keywords/residual-current-device","display_name":"Residual-current device","score":0.43371865153312683},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3358267545700073},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.2471950650215149},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.21179690957069397},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.16536539793014526},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.14552754163742065},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.14411023259162903},{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.10959431529045105}],"concepts":[{"id":"https://openalex.org/C23340480","wikidata":"https://www.wikidata.org/wiki/Q358932","display_name":"Inrush current","level":4,"score":0.8540197610855103},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.8149471282958984},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.6894626617431641},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.6013087034225464},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5559080243110657},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.5522093176841736},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5296432971954346},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.5183454751968384},{"id":"https://openalex.org/C2780968331","wikidata":"https://www.wikidata.org/wiki/Q1890115","display_name":"Shunt (medical)","level":2,"score":0.5180449485778809},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47767454385757446},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.4744347631931305},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4735535681247711},{"id":"https://openalex.org/C144534570","wikidata":"https://www.wikidata.org/wiki/Q5325","display_name":"Inductor","level":3,"score":0.46019673347473145},{"id":"https://openalex.org/C15116251","wikidata":"https://www.wikidata.org/wiki/Q337716","display_name":"Residual-current device","level":3,"score":0.43371865153312683},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3358267545700073},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2471950650215149},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.21179690957069397},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.16536539793014526},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.14552754163742065},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.14411023259162903},{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.10959431529045105},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iceei.2011.6021818","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.46000000834465027}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2025188302"],"related_works":["https://openalex.org/W2184491526","https://openalex.org/W3109370227","https://openalex.org/W2000536659","https://openalex.org/W2373498375","https://openalex.org/W2953190808","https://openalex.org/W2171570328","https://openalex.org/W1532321206","https://openalex.org/W3012190034","https://openalex.org/W2588018340","https://openalex.org/W4206833562"],"abstract_inverted_index":{"This":[0,177],"paper":[1],"presents":[2],"the":[3,6,11,18,51,54,65,91,100,110,113,119,152,159,165,168,172],"study":[4,178],"of":[5,57,93,112,121,131,137,154],"transient":[7],"phenomena":[8],"originating":[9],"from":[10],"shunt":[12,28,46,69,143],"reactor":[13,29,47,70,94,144,166],"energizing":[14,30,48],"and":[15,31,109,167],"de-energizing":[16],"at":[17,45],"Bulukumba":[19],"Substation.":[20],"The":[21],"unsymmetrical":[22,75],"phase":[23,40],"inrush":[24,41],"current":[25,35,42,80,95,105,155],"during":[26],"a":[27],"overvoltages":[32,98,114],"provoked":[33],"by":[34,183],"chopping":[36,106,156],"are":[37],"analyzed.":[38],"Unsymmetrical":[39],"that":[43],"occur":[44,108],"depend":[49,117],"on":[50,118],"time":[52,55,120],"in":[53],"instant":[56],"circuit":[58,101,122,169],"breaker":[59,102,123,170],"pole":[60,124],"operation":[61],"with":[62,71],"respect":[63],"to":[64,81,104,128],"reference":[66],"signal":[67],"At":[68],"solidly":[72],"grounded":[73],"neutral,":[74],"currents":[76],"cause":[77],"zero":[78],"sequence":[79],"flow":[82],"which":[83],"may":[84],"activate":[85],"ground":[86,133,147],"fault":[87,148],"relay":[88,132,138],"(mal-operation).":[89],"In":[90,126],"interruption":[92],"(de-energizing),":[96],"excessive":[97],"across":[99],"due":[103],"can":[107,139],"magnitude":[111],"will":[115,162],"also":[116],"operation.":[125],"order":[127],"avoid":[129],"mal-operation":[130],"fault,":[134],"good":[135],"setting":[136],"be":[140],"applied":[141],"for":[142,151],"protection":[145],"especially":[146],"relay.":[149],"As":[150],"case":[153],"over":[157],"voltages,":[158],"surge":[160],"arrester":[161],"protect":[163],"adequately":[164],"against":[171],"maximum":[173],"phase-to-ground":[174],"peak":[175],"voltage.":[176],"has":[179],"been":[180],"carried":[181],"out":[182],"simulation":[184],"using":[185],"software":[186],"ATP/EMTP.":[187]},"counts_by_year":[{"year":2022,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
