{"id":"https://openalex.org/W2101732338","doi":"https://doi.org/10.1109/iceei.2011.6021756","title":"In-service early indication of 500 kV circuit breaker function loss operated in PLN P3B Jawa Bali - Indonesia","display_name":"In-service early indication of 500 kV circuit breaker function loss operated in PLN P3B Jawa Bali - Indonesia","publication_year":2011,"publication_date":"2011-07-01","ids":{"openalex":"https://openalex.org/W2101732338","doi":"https://doi.org/10.1109/iceei.2011.6021756","mag":"2101732338"},"language":"en","primary_location":{"id":"doi:10.1109/iceei.2011.6021756","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021756","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039250625","display_name":"Y. Wibisana","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Y. Wibisana","raw_affiliation_strings":["PT PLN (Persero), P3B Jawa Bali, Jakarta","PT. PLN (Persero) P3B Jawa Bali- Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"PT PLN (Persero), P3B Jawa Bali, Jakarta","institution_ids":[]},{"raw_affiliation_string":"PT. PLN (Persero) P3B Jawa Bali- Jakarta, Indonesia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029199987","display_name":"R. Setyo Wibowo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"R. Setyo Wibowo","raw_affiliation_strings":["PT PLN (Persero), P3B Jawa Bali, Jakarta","PT. PLN (Persero) P3B Jawa Bali- Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"PT PLN (Persero), P3B Jawa Bali, Jakarta","institution_ids":[]},{"raw_affiliation_string":"PT. PLN (Persero) P3B Jawa Bali- Jakarta, Indonesia","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021059446","display_name":"H. Maryono","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"H. Maryono","raw_affiliation_strings":["PT. PLN (Persero) P3B Jawa Bali RJBR, Jl. M TOHA Km 04 Bandung, Indonesia"],"affiliations":[{"raw_affiliation_string":"PT. PLN (Persero) P3B Jawa Bali RJBR, Jl. M TOHA Km 04 Bandung, Indonesia","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5039250625"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0849,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.82592255,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9871000051498413,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13341","display_name":"Belt Conveyor Systems Engineering","score":0.9789999723434448,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.6516664028167725},{"id":"https://openalex.org/keywords/visual-inspection","display_name":"Visual inspection","score":0.6334348320960999},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5741408467292786},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.5231641530990601},{"id":"https://openalex.org/keywords/service","display_name":"Service (business)","score":0.4841209352016449},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.43417614698410034},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35862433910369873},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34094321727752686},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2519371509552002},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.18349960446357727},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.15208938717842102}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.6516664028167725},{"id":"https://openalex.org/C168820333","wikidata":"https://www.wikidata.org/wiki/Q448889","display_name":"Visual inspection","level":2,"score":0.6334348320960999},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5741408467292786},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.5231641530990601},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.4841209352016449},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43417614698410034},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35862433910369873},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34094321727752686},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2519371509552002},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.18349960446357727},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.15208938717842102},{"id":"https://openalex.org/C162853370","wikidata":"https://www.wikidata.org/wiki/Q39809","display_name":"Marketing","level":1,"score":0.0},{"id":"https://openalex.org/C78458016","wikidata":"https://www.wikidata.org/wiki/Q840400","display_name":"Evolutionary biology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iceei.2011.6021756","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021756","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.44999998807907104}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2373303942","https://openalex.org/W3111056319","https://openalex.org/W6708816347"],"related_works":["https://openalex.org/W2186957643","https://openalex.org/W4313289174","https://openalex.org/W2169296235","https://openalex.org/W2383147444","https://openalex.org/W2772771794","https://openalex.org/W2370462073","https://openalex.org/W2351129194","https://openalex.org/W2369017828","https://openalex.org/W2361809848","https://openalex.org/W2160345097"],"abstract_inverted_index":{"Since":[0],"year":[1],"of":[2,20,28,45,65,95,120],"2004":[3],"PLN":[4,32],"P3B":[5,33],"Jawa":[6,34],"Bali":[7,35],"has":[8,36],"been":[9,37],"changing":[10],"its":[11,72],"maintenance":[12],"strategy":[13,31],"from":[14],"time":[15],"based":[16,86],"to":[17,126,129],"the":[18,29,96],"combinations":[19],"time-based":[21],"and":[22,42,55,69,90,110],"condition-based":[23],"maintenance.":[24],"Currently,":[25],"as":[26,71],"part":[27],"new":[30],"implementing":[38],"a":[39],"visual":[40,51,66],"inspection":[41,67],"early":[43,59,97,118],"indication":[44,60,98,119],"equipment":[46,130],"function":[47,121],"loss":[48],"by":[49,80],"using":[50,81,115],"inspection,":[52],"in-service":[53,117],"monitoring":[54],"on-line":[56],"measurement.":[57],"This":[58],"uses":[61],"critical":[62,75],"failure":[63,76,131],"modes":[64,77],"item":[68],"thermovision":[70],"input.":[73],"The":[74,93],"are":[78,99],"identified":[79],"FMEA/FMECA":[82],"which":[83,104],"were":[84],"developed":[85],"on":[87],"statistical":[88],"data":[89],"engineering":[91],"senses.":[92],"output":[94],"either":[100],"1,6":[101],"or9":[102],"in":[103],"1":[105],"represents":[106],"bad,":[107],"6":[108],"fair":[109],"9":[111],"good":[112],"conditions.":[113],"By":[114],"this":[116],"loss,":[122],"we":[123],"will":[124],"able":[125],"obtain":[127],"symptoms":[128],"earlier.":[132]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}