{"id":"https://openalex.org/W2126792546","doi":"https://doi.org/10.1109/iceei.2011.6021600","title":"Condition assessment of 500/150 kV power transformer based on condition based maintenance","display_name":"Condition assessment of 500/150 kV power transformer based on condition based maintenance","publication_year":2011,"publication_date":"2011-07-01","ids":{"openalex":"https://openalex.org/W2126792546","doi":"https://doi.org/10.1109/iceei.2011.6021600","mag":"2126792546"},"language":"en","primary_location":{"id":"doi:10.1109/iceei.2011.6021600","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021600","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5012040951","display_name":"Ninil U.A. Wardani","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Ninil U.A. Wardani","raw_affiliation_strings":["PT. PLN (Persero) P3B Jawa Bali/Transmission System Department, Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"PT. PLN (Persero) P3B Jawa Bali/Transmission System Department, Jakarta, Indonesia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063623891","display_name":"A. P. Purnomoadi","orcid":"https://orcid.org/0000-0001-9614-0531"},"institutions":[{"id":"https://openalex.org/I4210091730","display_name":"Institute of Transportation and Logistic Trisakti","ror":"https://ror.org/00bw2gb04","country_code":"ID","type":"other","lineage":["https://openalex.org/I4210091730"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"A. P. Purnomoadi","raw_affiliation_strings":["Transm. Syst. Dept., Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"Transm. Syst. Dept., Jakarta, Indonesia","institution_ids":["https://openalex.org/I4210091730"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062401466","display_name":"H.I. Septiani","orcid":null},"institutions":[{"id":"https://openalex.org/I4210091730","display_name":"Institute of Transportation and Logistic Trisakti","ror":"https://ror.org/00bw2gb04","country_code":"ID","type":"other","lineage":["https://openalex.org/I4210091730"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"H.I. Septiani","raw_affiliation_strings":["Transm. Syst. Dept., Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"Transm. Syst. Dept., Jakarta, Indonesia","institution_ids":["https://openalex.org/I4210091730"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021703378","display_name":"Indera Arifianto","orcid":null},"institutions":[{"id":"https://openalex.org/I4210091730","display_name":"Institute of Transportation and Logistic Trisakti","ror":"https://ror.org/00bw2gb04","country_code":"ID","type":"other","lineage":["https://openalex.org/I4210091730"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"I. Arifianto","raw_affiliation_strings":["Transm. Syst. Dept., Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"Transm. Syst. Dept., Jakarta, Indonesia","institution_ids":["https://openalex.org/I4210091730"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5077663799","display_name":"Bambang Yudi Cahyono","orcid":"https://orcid.org/0000-0001-5210-5208"},"institutions":[{"id":"https://openalex.org/I4210091730","display_name":"Institute of Transportation and Logistic Trisakti","ror":"https://ror.org/00bw2gb04","country_code":"ID","type":"other","lineage":["https://openalex.org/I4210091730"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"B. Cahyono","raw_affiliation_strings":["Transm. Syst. Dept., Jakarta, Indonesia"],"affiliations":[{"raw_affiliation_string":"Transm. Syst. Dept., Jakarta, Indonesia","institution_ids":["https://openalex.org/I4210091730"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5012040951"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":{"value":0.14862706,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9769999980926514,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9769999980926514,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13706","display_name":"Management and Optimization Techniques","score":0.9211999773979187,"subfield":{"id":"https://openalex.org/subfields/1408","display_name":"Strategy and Management"},"field":{"id":"https://openalex.org/fields/14","display_name":"Business, Management and Accounting"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9196000099182129,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7815033197402954},{"id":"https://openalex.org/keywords/preventive-maintenance","display_name":"Preventive maintenance","score":0.7601024508476257},{"id":"https://openalex.org/keywords/corrective-maintenance","display_name":"Corrective maintenance","score":0.7563784718513489},{"id":"https://openalex.org/keywords/proactive-maintenance","display_name":"Proactive maintenance","score":0.7285716533660889},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"Predictive maintenance","score":0.7267459630966187},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"Condition-based maintenance","score":0.6735019087791443},{"id":"https://openalex.org/keywords/planned-maintenance","display_name":"Planned maintenance","score":0.6255651712417603},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.5678996443748474},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.5562555193901062},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.46887969970703125},{"id":"https://openalex.org/keywords/maintenance-actions","display_name":"Maintenance actions","score":0.4458664655685425},{"id":"https://openalex.org/keywords/operational-maintenance","display_name":"Operational maintenance","score":0.43455129861831665},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.41662395000457764},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3692029118537903},{"id":"https://openalex.org/keywords/computerized-maintenance-management-system","display_name":"Computerized maintenance management system","score":0.3274382948875427},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.19160258769989014},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.15169528126716614}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7815033197402954},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.7601024508476257},{"id":"https://openalex.org/C129529059","wikidata":"https://www.wikidata.org/wiki/Q2291518","display_name":"Corrective maintenance","level":3,"score":0.7563784718513489},{"id":"https://openalex.org/C141417316","wikidata":"https://www.wikidata.org/wiki/Q3278390","display_name":"Proactive maintenance","level":3,"score":0.7285716533660889},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.7267459630966187},{"id":"https://openalex.org/C2776907094","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Condition-based maintenance","level":2,"score":0.6735019087791443},{"id":"https://openalex.org/C4402595","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Planned maintenance","level":2,"score":0.6255651712417603},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.5678996443748474},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.5562555193901062},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.46887969970703125},{"id":"https://openalex.org/C2778814095","wikidata":"https://www.wikidata.org/wiki/Q6736790","display_name":"Maintenance actions","level":2,"score":0.4458664655685425},{"id":"https://openalex.org/C14922295","wikidata":"https://www.wikidata.org/wiki/Q7097783","display_name":"Operational maintenance","level":4,"score":0.43455129861831665},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.41662395000457764},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3692029118537903},{"id":"https://openalex.org/C115837547","wikidata":"https://www.wikidata.org/wiki/Q1122495","display_name":"Computerized maintenance management system","level":3,"score":0.3274382948875427},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.19160258769989014},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.15169528126716614}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iceei.2011.6021600","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iceei.2011.6021600","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2011 International Conference on Electrical Engineering and Informatics","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.5799999833106995,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W1507059639"],"related_works":["https://openalex.org/W4246303680","https://openalex.org/W2361723936","https://openalex.org/W23520515","https://openalex.org/W1585827041","https://openalex.org/W1989410761","https://openalex.org/W2388363692","https://openalex.org/W1483407033","https://openalex.org/W2332070375","https://openalex.org/W3091499708","https://openalex.org/W2367403801"],"abstract_inverted_index":{"Maintenance":[0],"on":[1,108,120,137,168,184,199,265],"high":[2],"Voltage/Extra":[3],"High":[4],"Voltage":[5],"equipment":[6,35,170],"can":[7],"be":[8,207],"divided":[9],"into":[10,238],"preventive":[11,29,66,73],"maintenance":[12,23,77,87,93,117,150,193,236],"and":[13,60,78,105,201,217],"corrective":[14,22],"maintenance.":[15,67,81,176],"Mostly,":[16],"the":[17,28,50,86,110,121,128,144,154,160,163,212,218,235,245,248],"cost":[18],"for":[19],"doing":[20],"a":[21,64,188,239],"is":[24,102,118,151,171,251],"much":[25],"higher":[26],"than":[27],"maintenance,":[30,74],"beside":[31],"of":[32,72,85,156,159,165,190,203],"when":[33],"an":[34,169],"break":[36],"down,":[37],"it":[38],"will":[39,179,206,229],"cause":[40],"another":[41],"problem":[42],"such":[43],"as":[44,187],"customer":[45],"dissatisfaction.":[46],"These":[47],"reasons":[48],"bring":[49],"consequence":[51],"to":[52,62,210,233],"any":[53],"electricity":[54],"utility":[55],"like":[56],"PLN":[57,138],"P3B":[58,139,271],"Jawa":[59,140,272],"Bali":[61,141],"do":[63],"reliable":[65,107],"There":[68],"are":[69,263],"two":[70],"types":[71],"e.g.":[75],"scheduled":[76,92,116],"condition":[79,148,166,174,182,191],"based":[80,119,136,149,152,175,192,198,264],"For":[82],"years,":[83],"most":[84],"methods":[88],"were":[89],"done":[90],"under":[91],"(oil":[94],"replacement,":[95],"shutdown":[96],"inspection/measurement,":[97],"etc),":[98],"but":[99],"this":[100],"method":[101,197],"less":[103,106],"cost-efficient":[104],"preventing":[109],"failure.":[111],"The":[112,195,226,259],"time":[113,145],"interval":[114,146],"in":[115,147,173,252,256,270],"statistical":[122],"data,":[123],"which":[124,242],"usually":[125],"came":[126],"from":[127],"factory":[129],"recommendation":[130],"(with":[131],"some":[132,157],"safety":[133],"factor)":[134],"or":[135,254],"experience,":[142],"while":[143],"upon":[153],"degradation":[155,167],"parameters":[158],"equipment.":[161],"So,":[162],"knowledge":[164],"important":[172],"This":[177],"paper":[178],"present":[180],"about":[181,214,231],"assessment":[183],"power":[185,204,249,268],"transformer":[186,205,250,269],"part":[189,228],"process.":[194],"causal":[196],"FMEA":[200],"FMECA":[202],"discussed":[208],"first":[209],"get":[211],"information":[213,246],"critical":[215],"component":[216],"suitable":[219],"monitoring":[220],"needed":[221],"at":[222],"sub":[223],"system":[224],"levels.":[225],"next":[227],"explain":[230],"how":[232],"compile":[234],"data":[237,260],"management":[240],"report":[241],"mainly":[243],"giving":[244],"whether":[247],"good/deteriorated":[253],"already":[255],"bad":[257],"condition.":[258],"presented":[261],"here":[262],"500/150":[266],"kV":[267],"Bali.":[273]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}