{"id":"https://openalex.org/W2168103196","doi":"https://doi.org/10.1109/icecs.2009.5410782","title":"Clock recovery for a 40 Gb/s QPSK optical receiver","display_name":"Clock recovery for a 40 Gb/s QPSK optical receiver","publication_year":2009,"publication_date":"2009-12-01","ids":{"openalex":"https://openalex.org/W2168103196","doi":"https://doi.org/10.1109/icecs.2009.5410782","mag":"2168103196"},"language":"en","primary_location":{"id":"doi:10.1109/icecs.2009.5410782","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icecs.2009.5410782","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 16th IEEE International Conference on Electronics, Circuits and Systems - (ICECS 2009)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026434083","display_name":"Naim Ben\u2010Hamida","orcid":"https://orcid.org/0000-0002-4031-2725"},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Naim Ben-Hamida","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055463216","display_name":"J.E. Sitch","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"John Sitch","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080572413","display_name":"Phillip Flemke","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Phillip Flemke","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053764181","display_name":"D. Pollex","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Daniel Pollex","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014120779","display_name":"Peter Schvan","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Peter Schvan","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065195100","display_name":"Yuriy Greshishchev","orcid":"https://orcid.org/0000-0002-6092-7313"},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Yuriy Greshishchev","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060360061","display_name":"Shing-Chi Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Shing-Chi Wang","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108536451","display_name":"Chris Falt","orcid":null},"institutions":[{"id":"https://openalex.org/I153908563","display_name":"Nortel (Canada)","ror":"https://ror.org/03rz4pm90","country_code":"CA","type":"company","lineage":["https://openalex.org/I153908563"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Chris Falt","raw_affiliation_strings":["Metro Ethernet Network, Nortel, Ottawa, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Metro Ethernet Network, Nortel, Ottawa, Canada","institution_ids":["https://openalex.org/I153908563"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I153908563"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.17742084,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"695","last_page":"698"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10299","display_name":"Photonic and Optical Devices","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11429","display_name":"Semiconductor Lasers and Optical Devices","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phase-locked-loop","display_name":"Phase-locked loop","score":0.8280061483383179},{"id":"https://openalex.org/keywords/voltage-controlled-oscillator","display_name":"Voltage-controlled oscillator","score":0.8052846193313599},{"id":"https://openalex.org/keywords/phase-noise","display_name":"Phase noise","score":0.6736172437667847},{"id":"https://openalex.org/keywords/jitter","display_name":"Jitter","score":0.664794921875},{"id":"https://openalex.org/keywords/clock-recovery","display_name":"Clock recovery","score":0.6407701969146729},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.621417760848999},{"id":"https://openalex.org/keywords/dbc","display_name":"dBc","score":0.6163915991783142},{"id":"https://openalex.org/keywords/frequency-offset","display_name":"Frequency offset","score":0.4925442636013031},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4879609942436218},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4813123941421509},{"id":"https://openalex.org/keywords/chip","display_name":"Chip","score":0.4647347927093506},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.4637129604816437},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3642723560333252},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31923186779022217},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.29001063108444214},{"id":"https://openalex.org/keywords/clock-signal","display_name":"Clock signal","score":0.20507535338401794},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.16589203476905823}],"concepts":[{"id":"https://openalex.org/C12707504","wikidata":"https://www.wikidata.org/wiki/Q52637","display_name":"Phase-locked loop","level":3,"score":0.8280061483383179},{"id":"https://openalex.org/C5291336","wikidata":"https://www.wikidata.org/wiki/Q852341","display_name":"Voltage-controlled oscillator","level":3,"score":0.8052846193313599},{"id":"https://openalex.org/C89631360","wikidata":"https://www.wikidata.org/wiki/Q1428766","display_name":"Phase noise","level":2,"score":0.6736172437667847},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.664794921875},{"id":"https://openalex.org/C2779835379","wikidata":"https://www.wikidata.org/wiki/Q2348121","display_name":"Clock recovery","level":4,"score":0.6407701969146729},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.621417760848999},{"id":"https://openalex.org/C193523891","wikidata":"https://www.wikidata.org/wiki/Q1771950","display_name":"dBc","level":3,"score":0.6163915991783142},{"id":"https://openalex.org/C49319798","wikidata":"https://www.wikidata.org/wiki/Q5502874","display_name":"Frequency offset","level":4,"score":0.4925442636013031},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4879609942436218},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4813123941421509},{"id":"https://openalex.org/C165005293","wikidata":"https://www.wikidata.org/wiki/Q1074500","display_name":"Chip","level":2,"score":0.4647347927093506},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.4637129604816437},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3642723560333252},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31923186779022217},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.29001063108444214},{"id":"https://openalex.org/C137059387","wikidata":"https://www.wikidata.org/wiki/Q426882","display_name":"Clock signal","level":3,"score":0.20507535338401794},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.16589203476905823},{"id":"https://openalex.org/C40409654","wikidata":"https://www.wikidata.org/wiki/Q375889","display_name":"Orthogonal frequency-division multiplexing","level":3,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icecs.2009.5410782","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icecs.2009.5410782","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2009 16th IEEE International Conference on Electronics, Circuits and Systems - (ICECS 2009)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8899999856948853}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1990182768","https://openalex.org/W1995131021","https://openalex.org/W2004202172","https://openalex.org/W2081870816","https://openalex.org/W2126062949","https://openalex.org/W2146813422","https://openalex.org/W6670889262"],"related_works":["https://openalex.org/W2141726610","https://openalex.org/W2976219355","https://openalex.org/W2061664740","https://openalex.org/W2540766993","https://openalex.org/W2089131288","https://openalex.org/W1600405202","https://openalex.org/W2911266525","https://openalex.org/W1486070987","https://openalex.org/W2086169776","https://openalex.org/W2017334866"],"abstract_inverted_index":{"A":[0],"clock":[1],"recovery":[2],"circuit":[3],"for":[4,28],"a":[5,29,57,86],"40":[6],"Gb/s":[7],"optical":[8],"coherent":[9,121],"receiver":[10,122],"realized":[11],"in":[12,92,115],"CMOS":[13],"90":[14],"nm":[15],"technology":[16],"is":[17,35,68,85,109],"presented.":[18],"The":[19,48,106],"core":[20,98],"PLL":[21,84,108],"generates":[22],"less":[23],"0.3":[24],"ps":[25],"rms":[26],"jitter":[27],"bandwidth":[30],"of":[31,77,111],"0.5":[32],"MHz.":[33],"This":[34],"mainly":[36],"due":[37],"to":[38],"the":[39,83,96,100,103,112,116],"on-chip":[40],"differential":[41],"LC":[42],"VCO":[43,49],"with":[44,56],"power":[45],"supply":[46],"regulation.":[47],"operates":[50],"at":[51,64],"11.5":[52],"GHz":[53],"center":[54],"frequency":[55,101],"25%":[58],"tuning":[59,104],"range.":[60],"Its":[61],"phase":[62],"noise":[63],"1":[65],"MHz":[66],"offset":[67],"better":[69],"than":[70],"-110":[71],"dBc/Hz,":[72],"and":[73,120],"consumes":[74],"3":[75],"mW":[76],"power.":[78],"In":[79],"tone":[80],"acquisition":[81,94],"mode":[82,95],"regular":[87],"charge":[88],"pump":[89],"PLL,":[90],"while":[91],"data":[93],"DSP":[97],"corrects":[99],"through":[102],"ports.":[105],"presented":[107],"one":[110],"key":[113],"components":[114],"24":[117],"Gs/s":[118],"ADC":[119],"chip.":[123]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
