{"id":"https://openalex.org/W1897145096","doi":"https://doi.org/10.1109/iccw.2015.7247155","title":"On the benefits of time-varying routing in realistic mobile backhaul networks","display_name":"On the benefits of time-varying routing in realistic mobile backhaul networks","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W1897145096","doi":"https://doi.org/10.1109/iccw.2015.7247155","mag":"1897145096"},"language":"en","primary_location":{"id":"doi:10.1109/iccw.2015.7247155","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iccw.2015.7247155","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communication Workshop (ICCW)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077028136","display_name":"Johannes Lessmann","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Johannes Lessmann","raw_affiliation_strings":["NEC Laboratories Europe, Heidelberg, Germany","NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany"],"affiliations":[{"raw_affiliation_string":"NEC Laboratories Europe, Heidelberg, Germany","institution_ids":[]},{"raw_affiliation_string":"NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101516907","display_name":"Yong Cheng","orcid":"https://orcid.org/0000-0003-2230-9730"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yong Cheng","raw_affiliation_strings":["NEC Laboratories Europe, Heidelberg, Germany","NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany"],"affiliations":[{"raw_affiliation_string":"NEC Laboratories Europe, Heidelberg, Germany","institution_ids":[]},{"raw_affiliation_string":"NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077934004","display_name":"Stefan Pfeiffer","orcid":"https://orcid.org/0000-0002-4410-9345"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Stefan Pfeiffer","raw_affiliation_strings":["NEC Laboratories Europe, Heidelberg, Germany","NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany"],"affiliations":[{"raw_affiliation_string":"NEC Laboratories Europe, Heidelberg, Germany","institution_ids":[]},{"raw_affiliation_string":"NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086187463","display_name":"Xavier Costa\u2010P\u00e9rez","orcid":"https://orcid.org/0000-0002-9654-6109"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xavier Costa-Perez","raw_affiliation_strings":["NEC Laboratories Europe, Heidelberg, Germany","NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany"],"affiliations":[{"raw_affiliation_string":"NEC Laboratories Europe, Heidelberg, Germany","institution_ids":[]},{"raw_affiliation_string":"NEC Laboratories Europe, Kurf\u00fcrsten-Anlage 36, D-69115, Heidelberg, Germany","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5077028136"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.06095782,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"56","last_page":"61"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10138","display_name":"Network Traffic and Congestion Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10138","display_name":"Network Traffic and Congestion Control","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backhaul","display_name":"Backhaul (telecommunications)","score":0.9141185283660889},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7365877032279968},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6049134731292725},{"id":"https://openalex.org/keywords/static-routing","display_name":"Static routing","score":0.5200405120849609},{"id":"https://openalex.org/keywords/multipath-routing","display_name":"Multipath routing","score":0.5103482604026794},{"id":"https://openalex.org/keywords/routing","display_name":"Routing (electronic design automation)","score":0.4970898926258087},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.44662222266197205},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.42886000871658325},{"id":"https://openalex.org/keywords/dynamic-source-routing","display_name":"Dynamic Source Routing","score":0.41869574785232544},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.38200119137763977},{"id":"https://openalex.org/keywords/routing-protocol","display_name":"Routing protocol","score":0.24651139974594116},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1597588062286377},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.11803287267684937}],"concepts":[{"id":"https://openalex.org/C103760667","wikidata":"https://www.wikidata.org/wiki/Q798444","display_name":"Backhaul (telecommunications)","level":3,"score":0.9141185283660889},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7365877032279968},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6049134731292725},{"id":"https://openalex.org/C204948658","wikidata":"https://www.wikidata.org/wiki/Q1119410","display_name":"Static routing","level":4,"score":0.5200405120849609},{"id":"https://openalex.org/C76522221","wikidata":"https://www.wikidata.org/wiki/Q5035396","display_name":"Multipath routing","level":5,"score":0.5103482604026794},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.4970898926258087},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.44662222266197205},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.42886000871658325},{"id":"https://openalex.org/C9659607","wikidata":"https://www.wikidata.org/wiki/Q1268903","display_name":"Dynamic Source Routing","level":4,"score":0.41869574785232544},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.38200119137763977},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.24651139974594116},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1597588062286377},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.11803287267684937},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iccw.2015.7247155","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iccw.2015.7247155","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communication Workshop (ICCW)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.550000011920929,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1584019048","https://openalex.org/W1589657219","https://openalex.org/W2028063420","https://openalex.org/W2117881830","https://openalex.org/W2156442470","https://openalex.org/W2163907500","https://openalex.org/W2165030634","https://openalex.org/W7010224180"],"related_works":["https://openalex.org/W757657516","https://openalex.org/W2539097916","https://openalex.org/W2251995179","https://openalex.org/W2082566976","https://openalex.org/W2607223747","https://openalex.org/W2361465121","https://openalex.org/W2619478018","https://openalex.org/W2793943525","https://openalex.org/W3134665879","https://openalex.org/W4214896794"],"abstract_inverted_index":{"Since":[0],"traffic":[1,87],"load":[2],"in":[3,16,30,52,101,107],"mobile":[4,80,124],"networks":[5],"typically":[6],"changes":[7,15],"significantly":[8],"over":[9],"time,":[10],"time-varying":[11,34,98],"routing,":[12],"where":[13],"routing":[14,35,99],"certain":[17],"time":[18],"intervals,":[19],"seems":[20],"an":[21],"obvious":[22],"solution.":[23],"Yet":[24],"multiple":[25],"researchers":[26],"have":[27,103],"claimed":[28],"independently":[29],"the":[31,72,117],"past,":[32],"that":[33,58,94,97],"does":[36],"not":[37],"lead":[38],"to":[39,63],"worthwhile":[40],"benefits":[41,118],"given":[42],"its":[43],"overhead.":[44],"In":[45],"this":[46,50],"paper,":[47],"we":[48],"study":[49],"issue":[51],"a":[53,85,128],"systematic":[54],"way.":[55],"We":[56,83],"argue":[57],"previous":[59],"claims":[60],"are":[61],"due":[62],"focusing":[64],"on":[65,93,116,122],"too":[66],"narrow":[67],"optimization":[68],"metrics":[69,77],"and":[70,92],"demonstrate":[71],"poor":[73],"expressiveness":[74],"of":[75,109],"such":[76],"using":[78],"real":[79,123],"backhaul":[81,125],"topologies.":[82],"propose":[84],"novel":[86],"engineering":[88],"metric,":[89],"capacity":[90],"variation,":[91],"basis,":[95],"prove":[96],"can":[100],"fact":[102],"great":[104],"benefits,":[105],"particularly":[106],"terms":[108],"infrastructure":[110],"CAPEX":[111],"costs.":[112],"A":[113],"quantitative":[114],"evaluation":[115],"is":[119],"provided":[120],"based":[121],"data":[126],"from":[127],"European":[129],"operators.":[130]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
