{"id":"https://openalex.org/W4291700087","doi":"https://doi.org/10.1109/icccs55155.2022.9846754","title":"Architecture Design of Coordination Transmission System for Mountainous Microgrid Based on Power Line Carrier","display_name":"Architecture Design of Coordination Transmission System for Mountainous Microgrid Based on Power Line Carrier","publication_year":2022,"publication_date":"2022-04-22","ids":{"openalex":"https://openalex.org/W4291700087","doi":"https://doi.org/10.1109/icccs55155.2022.9846754"},"language":"en","primary_location":{"id":"doi:10.1109/icccs55155.2022.9846754","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icccs55155.2022.9846754","pdf_url":null,"source":{"id":"https://openalex.org/S4363608130","display_name":"2022 7th International Conference on Computer and Communication Systems (ICCCS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 7th International Conference on Computer and Communication Systems (ICCCS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100374415","display_name":"Bo Li","orcid":"https://orcid.org/0000-0002-3226-388X"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Bo Li","raw_affiliation_strings":["Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","institution_ids":["https://openalex.org/I74872605"]},{"raw_affiliation_string":"Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101644114","display_name":"Zhan Shi","orcid":"https://orcid.org/0009-0005-5148-1902"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhan Shi","raw_affiliation_strings":["Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","institution_ids":["https://openalex.org/I74872605"]},{"raw_affiliation_string":"Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101177634","display_name":"Yutu Liang","orcid":null},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yutu Liang","raw_affiliation_strings":["Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China"],"affiliations":[{"raw_affiliation_string":"Guangdong Power Grid Co., Ltd. Power Dispatching Control Center,Communication Management Department,China","institution_ids":["https://openalex.org/I74872605"]},{"raw_affiliation_string":"Communication Management Department, Guangdong Power Grid Co., Ltd. Power Dispatching Control Center, China","institution_ids":["https://openalex.org/I74872605"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100374415"],"corresponding_institution_ids":["https://openalex.org/I74872605"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.08745829,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"15","issue":null,"first_page":"761","last_page":"766"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10796","display_name":"Cooperative Communication and Network Coding","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.984499990940094,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11458","display_name":"Advanced Wireless Communication Technologies","score":0.9663000106811523,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8444868326187134},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6150158047676086},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6051825881004333},{"id":"https://openalex.org/keywords/power-line-communication","display_name":"Power-line communication","score":0.5946018099784851},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5639200210571289},{"id":"https://openalex.org/keywords/adaptability","display_name":"Adaptability","score":0.5521824359893799},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4888400435447693},{"id":"https://openalex.org/keywords/communications-system","display_name":"Communications system","score":0.4741101861000061},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4252352714538574},{"id":"https://openalex.org/keywords/architecture","display_name":"Architecture","score":0.4173475503921509},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3719485402107239},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.36294275522232056},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.32296085357666016},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.31480008363723755},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2378968596458435},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.22053420543670654},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.21328115463256836}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8444868326187134},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6150158047676086},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6051825881004333},{"id":"https://openalex.org/C132885549","wikidata":"https://www.wikidata.org/wiki/Q271870","display_name":"Power-line communication","level":3,"score":0.5946018099784851},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5639200210571289},{"id":"https://openalex.org/C177606310","wikidata":"https://www.wikidata.org/wiki/Q5674297","display_name":"Adaptability","level":2,"score":0.5521824359893799},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4888400435447693},{"id":"https://openalex.org/C101765175","wikidata":"https://www.wikidata.org/wiki/Q577764","display_name":"Communications system","level":2,"score":0.4741101861000061},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4252352714538574},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.4173475503921509},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3719485402107239},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.36294275522232056},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.32296085357666016},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.31480008363723755},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2378968596458435},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.22053420543670654},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21328115463256836},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icccs55155.2022.9846754","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icccs55155.2022.9846754","pdf_url":null,"source":{"id":"https://openalex.org/S4363608130","display_name":"2022 7th International Conference on Computer and Communication Systems (ICCCS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2022 7th International Conference on Computer and Communication Systems (ICCCS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.49000000953674316}],"awards":[],"funders":[{"id":"https://openalex.org/F4320323192","display_name":"China Southern Power Grid","ror":"https://ror.org/03hkh9419"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2096973938","https://openalex.org/W3136655239"],"related_works":["https://openalex.org/W2393297133","https://openalex.org/W2385415149","https://openalex.org/W2545563450","https://openalex.org/W2907465462","https://openalex.org/W2366811818","https://openalex.org/W2546705843","https://openalex.org/W2372552615","https://openalex.org/W2356392619","https://openalex.org/W3171442923","https://openalex.org/W1970980060"],"abstract_inverted_index":{"The":[0,74],"business":[1,47],"of":[2,28,31,44,48,83,90],"the":[3,34,42,45,49,55,62,69,81,84,88],"mountain":[4,50,70],"microgrid":[5],"is":[6,52,59,72,94],"continuously":[7],"diversified,":[8],"including":[9],"small":[10],"hydropower":[11],"services,":[12],"end":[13],"voltage":[14],"management,":[15],"electricity":[16],"information":[17],"collection,":[18],"line":[19],"fault":[20],"repair,":[21],"etc.":[22],"This":[23],"paper":[24],"introduces":[25],"communication":[26,40,65,77],"needs":[27],"different":[29,39],"types":[30],"business.":[32],"At":[33],"same":[35],"time,":[36],"according":[37],"to":[38],"methods,":[41],"adaptability":[43],"differentiated":[46],"micro-grid":[51,71],"selected,":[53,60],"and":[54,61,93],"reasonable":[56],"networking":[57],"scheme":[58],"multimode":[63],"fusion":[64,76],"system":[66,78],"architecture":[67],"facing":[68],"constructed.":[73],"multi-mode":[75],"can":[79],"improve":[80],"reliability":[82],"mountainous":[85],"area,":[86],"reducing":[87],"length":[89],"power":[91],"failure,":[92],"important":[95],"value.":[96]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
