{"id":"https://openalex.org/W2171636067","doi":"https://doi.org/10.1109/icccn.2007.4318007","title":"Design Techniques for Streamlined Integration and Fault Tolerance in a Distributed Sensor System for Line-crossing Recognition","display_name":"Design Techniques for Streamlined Integration and Fault Tolerance in a Distributed Sensor System for Line-crossing Recognition","publication_year":2007,"publication_date":"2007-08-01","ids":{"openalex":"https://openalex.org/W2171636067","doi":"https://doi.org/10.1109/icccn.2007.4318007","mag":"2171636067"},"language":"en","primary_location":{"id":"doi:10.1109/icccn.2007.4318007","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icccn.2007.4318007","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 16th International Conference on Computer Communications and Networks","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089461692","display_name":"Chung-Ching Shen","orcid":null},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Chung-Ching Shen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011351607","display_name":"Roni Kupershtok","orcid":null},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Roni Kupershtok","raw_affiliation_strings":["Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038036261","display_name":"Shuvra S. Bhattacharyya","orcid":"https://orcid.org/0000-0001-7719-1106"},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Shuvra S. Bhattacharyya","raw_affiliation_strings":["Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA","institution_ids":["https://openalex.org/I66946132"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5076571019","display_name":"Neil Goldsman","orcid":null},"institutions":[{"id":"https://openalex.org/I66946132","display_name":"University of Maryland, College Park","ror":"https://ror.org/047s2c258","country_code":"US","type":"education","lineage":["https://openalex.org/I66946132"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Neil Goldsman","raw_affiliation_strings":["Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, and Institute for Advanced Computer Studies, University of Maryland, College Park, USA","institution_ids":["https://openalex.org/I66946132"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.3369,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.69707837,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1339","last_page":"1344"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12784","display_name":"Modular Robots and Swarm Intelligence","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13052","display_name":"Molecular Communication and Nanonetworks","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/handshaking","display_name":"Handshaking","score":0.7815052270889282},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.6889259815216064},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6864973306655884},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.5883988738059998},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.5786188840866089},{"id":"https://openalex.org/keywords/asynchronous-communication","display_name":"Asynchronous communication","score":0.5366688370704651},{"id":"https://openalex.org/keywords/key-distribution-in-wireless-sensor-networks","display_name":"Key distribution in wireless sensor networks","score":0.5094779133796692},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.46415671706199646},{"id":"https://openalex.org/keywords/sensor-node","display_name":"Sensor node","score":0.42884647846221924},{"id":"https://openalex.org/keywords/node","display_name":"Node (physics)","score":0.4216534495353699},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.37004154920578003},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35996267199516296},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.34948551654815674},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.33386409282684326},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.2566552758216858},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19660106301307678},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.08979874849319458}],"concepts":[{"id":"https://openalex.org/C58861099","wikidata":"https://www.wikidata.org/wiki/Q548838","display_name":"Handshaking","level":2,"score":0.7815052270889282},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.6889259815216064},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6864973306655884},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.5883988738059998},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.5786188840866089},{"id":"https://openalex.org/C151319957","wikidata":"https://www.wikidata.org/wiki/Q752739","display_name":"Asynchronous communication","level":2,"score":0.5366688370704651},{"id":"https://openalex.org/C41971633","wikidata":"https://www.wikidata.org/wiki/Q6398155","display_name":"Key distribution in wireless sensor networks","level":4,"score":0.5094779133796692},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.46415671706199646},{"id":"https://openalex.org/C111185680","wikidata":"https://www.wikidata.org/wiki/Q3866206","display_name":"Sensor node","level":5,"score":0.42884647846221924},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.4216534495353699},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.37004154920578003},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35996267199516296},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.34948551654815674},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.33386409282684326},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.2566552758216858},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19660106301307678},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.08979874849319458},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icccn.2007.4318007","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icccn.2007.4318007","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2007 16th International Conference on Computer Communications and Networks","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1481697750","https://openalex.org/W1986805195","https://openalex.org/W2099178332","https://openalex.org/W2120211800","https://openalex.org/W2128037380","https://openalex.org/W2136221591","https://openalex.org/W2159013099","https://openalex.org/W2164802361","https://openalex.org/W2165677640","https://openalex.org/W2167088460","https://openalex.org/W3145507822","https://openalex.org/W4234048677","https://openalex.org/W4242549871","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W2383170059","https://openalex.org/W2120480196","https://openalex.org/W2799361348","https://openalex.org/W1977342959","https://openalex.org/W2053773563","https://openalex.org/W2148549110","https://openalex.org/W2564820291","https://openalex.org/W2067121920","https://openalex.org/W2536494564","https://openalex.org/W2371193381"],"abstract_inverted_index":{"Distributed":[0],"sensor":[1,6,20,35,84,143,192],"system":[2,36,53,85],"applications":[3,16],"(e.g.,":[4],"wireless":[5,191],"networks)":[7],"have":[8],"been":[9],"studied":[10],"extensively":[11],"in":[12,49,103,122,142],"recent":[13],"years.":[14],"Such":[15],"involve":[17],"resource-limited":[18],"embedded":[19],"nodes":[21],"that":[22,114,201],"communicate":[23],"with":[24,154],"each":[25],"other":[26],"through":[27,185],"self-organizing":[28],"protocols.":[29,171],"Depending":[30],"on":[31,168,203],"application":[32,200],"requirements,":[33],"distributed":[34,83,197],"design":[37,57],"may":[38],"include":[39],"protocol":[40],"and":[41,51,64,111,138,158,182,195],"prototype":[42,190],"implementation.":[43],"Prototype":[44],"implementation":[45],"is":[46,58,94,109,117],"especially":[47],"useful":[48],"establishing":[50],"maintaining":[52],"functionality":[54],"as":[55],"the":[56,104,136,174],"customized":[59],"to":[60,76,95,163,179],"satisfy":[61],"size,":[62],"energy,":[63],"cost":[65],"constraints.":[66],"In":[67],"this":[68,92,204],"paper,":[69],"we":[70],"present":[71,127],"a":[72,81,147,188,196],"streamlined,":[73],"application-specific":[74],"approach":[75,93,108,131],"incorporating":[77],"fault":[78,115,180],"tolerance":[79,116,181],"into":[80,101],"TDMA-based":[82],"for":[86,132,150],"line-crossing":[87,198],"recognition.":[88],"The":[89],"objective":[90],"of":[91,176],"prevent":[96],"node":[97],"failures":[98,102],"from":[99],"translating":[100],"overall":[105],"system.":[106],"Our":[107],"specialized":[110],"light-weight":[112],"so":[113],"achieved":[118],"without":[119],"significant":[120],"degradation":[121],"energy":[123,160],"efficiency.":[124],"We":[125,172],"also":[126],"an":[128],"asynchronous":[129],"handshaking":[130],"providing":[133],"synchronization":[134,153],"between":[135],"transceiver":[137],"digital":[139],"processing":[140],"subsystem":[141],"node.":[144],"This":[145],"provides":[146],"general":[148],"method":[149],"achieving":[151],"such":[152],"reduced":[155,159],"hardware":[156],"requirements":[157],"consumption":[161],"compared":[162],"conventional":[164],"approaches,":[165],"which":[166],"rely":[167],"generic":[169],"interface":[170],"demonstrate":[173],"capabilities":[175],"our":[177],"approaches":[178],"transceiver-processor":[183],"integration":[184],"experiments":[186],"involving":[187],"complete":[189],"network":[193],"test-bed,":[194],"recognition":[199],"runs":[202],"test-bed.":[205]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
