{"id":"https://openalex.org/W7147301591","doi":"https://doi.org/10.1109/iccbn67217.2025.11447868","title":"A Dual-Branch Architecture for Multimodal Cyberattack Detection in Power Monitoring Systems","display_name":"A Dual-Branch Architecture for Multimodal Cyberattack Detection in Power Monitoring Systems","publication_year":2025,"publication_date":"2025-11-27","ids":{"openalex":"https://openalex.org/W7147301591","doi":"https://doi.org/10.1109/iccbn67217.2025.11447868"},"language":null,"primary_location":{"id":"doi:10.1109/iccbn67217.2025.11447868","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iccbn67217.2025.11447868","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 13th International Conference on Communications and Broadband Networking (ICCBN)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5132548819","display_name":"Feng Sun","orcid":null},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN","US"],"is_corresponding":false,"raw_author_name":"Feng Sun","raw_affiliation_strings":["Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China","institution_ids":["https://openalex.org/I1335486098","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103058792","display_name":"Shuai Ren","orcid":"https://orcid.org/0000-0002-5599-3631"},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN","US"],"is_corresponding":false,"raw_author_name":"Shuai Ren","raw_affiliation_strings":["Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China","institution_ids":["https://openalex.org/I1335486098","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5132694041","display_name":"Tong Li","orcid":null},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN","US"],"is_corresponding":false,"raw_author_name":"Tong Li","raw_affiliation_strings":["Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China","institution_ids":["https://openalex.org/I1335486098","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046402236","display_name":"J. Bradley Chen","orcid":"https://orcid.org/0009-0008-9491-2524"},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]},{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN","US"],"is_corresponding":false,"raw_author_name":"Jian Chen","raw_affiliation_strings":["Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energy Internet Technology Center, State Grid Liaoning Electric Power Co., Ltd. Electric Power, Science Research Institute,Shenyang,China","institution_ids":["https://openalex.org/I1335486098","https://openalex.org/I4210126065"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101110293","display_name":"Ruichao Xu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210126065","display_name":"Shanghai Electric (China)","ror":"https://ror.org/0314qy595","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210126065"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ruichao Xu","raw_affiliation_strings":["Power Dispatch and Control Center, State Grid Liaoning Electric Power Co., Ltd.,Shenyang,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Power Dispatch and Control Center, State Grid Liaoning Electric Power Co., Ltd.,Shenyang,China","institution_ids":["https://openalex.org/I4210126065"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101794311","display_name":"Jiaqi Lin","orcid":"https://orcid.org/0000-0003-1383-6723"},"institutions":[{"id":"https://openalex.org/I139759216","display_name":"Beijing University of Posts and Telecommunications","ror":"https://ror.org/04w9fbh59","country_code":"CN","type":"education","lineage":["https://openalex.org/I139759216"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiaqi Lin","raw_affiliation_strings":["Network Management Research Center, Beijing University of Posts and Telecommunications,Beijing,China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Network Management Research Center, Beijing University of Posts and Telecommunications,Beijing,China","institution_ids":["https://openalex.org/I139759216"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"46","last_page":"50"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.5619000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.5619000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11598","display_name":"Internet Traffic Analysis and Secure E-voting","score":0.12200000137090683,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.06539999693632126,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/telemetry","display_name":"Telemetry","score":0.5131999850273132},{"id":"https://openalex.org/keywords/architecture","display_name":"Architecture","score":0.46299999952316284},{"id":"https://openalex.org/keywords/industrial-control-system","display_name":"Industrial control system","score":0.3666999936103821},{"id":"https://openalex.org/keywords/binary-number","display_name":"Binary number","score":0.3472999930381775},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.34279999136924744},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.3427000045776367},{"id":"https://openalex.org/keywords/systems-architecture","display_name":"Systems architecture","score":0.3255999982357025},{"id":"https://openalex.org/keywords/intrusion-detection-system","display_name":"Intrusion detection system","score":0.32120001316070557}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6747999787330627},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.5515000224113464},{"id":"https://openalex.org/C183121708","wikidata":"https://www.wikidata.org/wiki/Q209867","display_name":"Telemetry","level":2,"score":0.5131999850273132},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.46299999952316284},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.38839998841285706},{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.3666999936103821},{"id":"https://openalex.org/C48372109","wikidata":"https://www.wikidata.org/wiki/Q3913","display_name":"Binary number","level":2,"score":0.3472999930381775},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.34279999136924744},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.3427000045776367},{"id":"https://openalex.org/C98025372","wikidata":"https://www.wikidata.org/wiki/Q477538","display_name":"Systems architecture","level":3,"score":0.3255999982357025},{"id":"https://openalex.org/C35525427","wikidata":"https://www.wikidata.org/wiki/Q745881","display_name":"Intrusion detection system","level":2,"score":0.32120001316070557},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3118000030517578},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.31150001287460327},{"id":"https://openalex.org/C193415008","wikidata":"https://www.wikidata.org/wiki/Q639681","display_name":"Network architecture","level":2,"score":0.30660000443458557},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.30570000410079956},{"id":"https://openalex.org/C52622490","wikidata":"https://www.wikidata.org/wiki/Q1026626","display_name":"Feature extraction","level":2,"score":0.29670000076293945},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.28700000047683716},{"id":"https://openalex.org/C2776401178","wikidata":"https://www.wikidata.org/wiki/Q12050496","display_name":"Feature (linguistics)","level":2,"score":0.28439998626708984},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26840001344680786},{"id":"https://openalex.org/C81877898","wikidata":"https://www.wikidata.org/wiki/Q1965787","display_name":"Network monitoring","level":2,"score":0.26489999890327454},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.25780001282691956},{"id":"https://openalex.org/C2987858997","wikidata":"https://www.wikidata.org/wiki/Q7312160","display_name":"Monitoring and control","level":2,"score":0.25769999623298645},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.2563999891281128}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/iccbn67217.2025.11447868","is_oa":false,"landing_page_url":"https://doi.org/10.1109/iccbn67217.2025.11447868","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 13th International Conference on Communications and Broadband Networking (ICCBN)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W2002619227","https://openalex.org/W2038651258","https://openalex.org/W2075300315","https://openalex.org/W2128240246","https://openalex.org/W2154971967","https://openalex.org/W2319367234","https://openalex.org/W2332912277","https://openalex.org/W2579603034","https://openalex.org/W2950361482","https://openalex.org/W2963758027","https://openalex.org/W3013642240","https://openalex.org/W3092207285","https://openalex.org/W3128634608","https://openalex.org/W3130070946","https://openalex.org/W3169450514","https://openalex.org/W3170937175","https://openalex.org/W4283318673","https://openalex.org/W4308158032","https://openalex.org/W4323903173","https://openalex.org/W4396817384","https://openalex.org/W4400869256","https://openalex.org/W4411949448"],"related_works":[],"abstract_inverted_index":{"Power":[0],"monitoring":[1],"systems":[2],"face":[3],"sophisticated":[4],"cyberphysical":[5],"attacks":[6],"exploiting":[7],"both":[8,90],"network":[9,23],"vulnerabilities":[10],"and":[11,92],"control":[12],"logic.":[13],"Single-modal":[14],"detection":[15],"methods":[16],"create":[17],"blind":[18],"spots":[19],"by":[20],"analyzing":[21],"either":[22],"traffic":[24,43],"or":[25],"telemetry":[26,38],"data":[27],"in":[28],"isolation.":[29],"We":[30],"propose":[31],"a":[32,79],"dual-branch":[33],"neural":[34],"architecture":[35],"fusing":[36],"Transformer-based":[37],"modeling":[39],"with":[40,56],"multi-scale":[41],"CNN":[42],"analysis.":[44],"The":[45],"Transformer":[46],"captures":[47],"long-range":[48],"temporal":[49],"dependencies":[50],"through":[51],"self-attention,":[52],"while":[53],"parallel":[54],"CNNs":[55],"kernels":[57],"<tex":[58],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[59],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">$k":[60],"\\in\\{3,5,7\\}$</tex>":[61],"extract":[62],"multi-temporal":[63],"attack":[64],"patterns.":[65],"Our":[66],"approach":[67],"requires":[68],"only":[69],"binary":[70],"attack/normal":[71],"labels,":[72],"addressing":[73],"practical":[74],"industrial":[75],"constraints.":[76],"Evaluation":[77],"on":[78],"real-world":[80],"dataset":[81],"demonstrates":[82],"superior":[83],"performance":[84],"over":[85],"single-modal":[86],"baselines,":[87],"effectively":[88],"detecting":[89],"network-centric":[91],"controlcentric":[93],"attacks.":[94]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2026-04-02T00:00:00"}
