{"id":"https://openalex.org/W2742362005","doi":"https://doi.org/10.1109/icca.2017.8003064","title":"Adaptive optimization for smart operation of cyber-physical systems: A thermostatic zoning test case","display_name":"Adaptive optimization for smart operation of cyber-physical systems: A thermostatic zoning test case","publication_year":2017,"publication_date":"2017-07-01","ids":{"openalex":"https://openalex.org/W2742362005","doi":"https://doi.org/10.1109/icca.2017.8003064","mag":"2742362005"},"language":"en","primary_location":{"id":"doi:10.1109/icca.2017.8003064","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icca.2017.8003064","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 13th IEEE International Conference on Control &amp; Automation (ICCA)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014467032","display_name":"Christos Korkas","orcid":"https://orcid.org/0000-0002-2491-2659"},"institutions":[{"id":"https://openalex.org/I151727225","display_name":"Harbin Engineering University","ror":"https://ror.org/03x80pn82","country_code":"CN","type":"education","lineage":["https://openalex.org/I151727225"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Christos Korkas","raw_affiliation_strings":["College of Information and Communications Engineering, Harbin Engineering University, Harbin, China"],"affiliations":[{"raw_affiliation_string":"College of Information and Communications Engineering, Harbin Engineering University, Harbin, China","institution_ids":["https://openalex.org/I151727225"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055979973","display_name":"Simone Baldi","orcid":"https://orcid.org/0000-0001-9752-8925"},"institutions":[{"id":"https://openalex.org/I151727225","display_name":"Harbin Engineering University","ror":"https://ror.org/03x80pn82","country_code":"CN","type":"education","lineage":["https://openalex.org/I151727225"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Simone Baldi","raw_affiliation_strings":["College of Information and Communications Engineering, Harbin Engineering University, Harbin, China"],"affiliations":[{"raw_affiliation_string":"College of Information and Communications Engineering, Harbin Engineering University, Harbin, China","institution_ids":["https://openalex.org/I151727225"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071596476","display_name":"Elias B. Kosmatopoulos","orcid":"https://orcid.org/0000-0002-3735-4238"},"institutions":[{"id":"https://openalex.org/I151727225","display_name":"Harbin Engineering University","ror":"https://ror.org/03x80pn82","country_code":"CN","type":"education","lineage":["https://openalex.org/I151727225"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Elias Kosmatopoulos","raw_affiliation_strings":["College of Information and Communications Engineering, Harbin Engineering University, Harbin, China"],"affiliations":[{"raw_affiliation_string":"College of Information and Communications Engineering, Harbin Engineering University, Harbin, China","institution_ids":["https://openalex.org/I151727225"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5014467032"],"corresponding_institution_ids":["https://openalex.org/I151727225"],"apc_list":null,"apc_paid":null,"fwci":0.43,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.65007256,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"1","issue":null,"first_page":"224","last_page":"229"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9909999966621399,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8374830484390259},{"id":"https://openalex.org/keywords/exploit","display_name":"Exploit","score":0.6766960620880127},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.602215588092804},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.5843823552131653},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.5815709233283997},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.556792140007019},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.515512228012085},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.498063325881958},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.47116002440452576},{"id":"https://openalex.org/keywords/set","display_name":"Set (abstract data type)","score":0.4279938340187073},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.41687849164009094},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3902775049209595},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.33417510986328125},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2975323796272278},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.27397620677948},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.26482024788856506},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.1944437026977539},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.15359815955162048},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.12546059489250183},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09379252791404724}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8374830484390259},{"id":"https://openalex.org/C165696696","wikidata":"https://www.wikidata.org/wiki/Q11287","display_name":"Exploit","level":2,"score":0.6766960620880127},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.602215588092804},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.5843823552131653},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.5815709233283997},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.556792140007019},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.515512228012085},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.498063325881958},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.47116002440452576},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.4279938340187073},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.41687849164009094},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3902775049209595},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.33417510986328125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2975323796272278},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.27397620677948},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.26482024788856506},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.1944437026977539},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.15359815955162048},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.12546059489250183},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09379252791404724},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icca.2017.8003064","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icca.2017.8003064","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 13th IEEE International Conference on Control &amp; Automation (ICCA)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7300000190734863,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320338370","display_name":"FP7 Information and Communication Technologies","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W645846159","https://openalex.org/W756263691","https://openalex.org/W1804641549","https://openalex.org/W1976162041","https://openalex.org/W1989475308","https://openalex.org/W1991447462","https://openalex.org/W2010739835","https://openalex.org/W2024030054","https://openalex.org/W2032717142","https://openalex.org/W2034776151","https://openalex.org/W2044742906","https://openalex.org/W2059049926","https://openalex.org/W2061434834","https://openalex.org/W2064615357","https://openalex.org/W2068060907","https://openalex.org/W2080637564","https://openalex.org/W2089758604","https://openalex.org/W2092407123","https://openalex.org/W2098941484","https://openalex.org/W2108152153","https://openalex.org/W2112592323","https://openalex.org/W2116532272","https://openalex.org/W2163121678","https://openalex.org/W2188224396","https://openalex.org/W2201582605","https://openalex.org/W2276272497","https://openalex.org/W2307546884","https://openalex.org/W2341171179","https://openalex.org/W2980797340","https://openalex.org/W4285719527","https://openalex.org/W6686838234"],"related_works":["https://openalex.org/W1997024178","https://openalex.org/W2749654269","https://openalex.org/W2326668440","https://openalex.org/W4390970874","https://openalex.org/W2735458449","https://openalex.org/W2538009942","https://openalex.org/W3031841740","https://openalex.org/W4240359851","https://openalex.org/W2329485921","https://openalex.org/W4391423612"],"abstract_inverted_index":{"In":[0,50],"the":[1,5,37,41,74,81,84,90],"current":[2],"state":[3],"of":[4,27,33,40,73,83,89],"art":[6],"load":[7,58,65],"management":[8,59,66,88],"and":[9,46,93],"demand":[10],"response":[11],"actions":[12],"in":[13],"smart":[14],"buildings":[15],"are":[16],"often":[17,35],"predetermined":[18],"by":[19],"a":[20,24,56,62],"field":[21],"engineer":[22],"to":[23,100],"fixed":[25,31],"set":[26,32],"(rule-based)":[28],"options.":[29],"This":[30],"options":[34],"neglects":[36],"cyber-physical":[38],"nature":[39],"building":[42,47],"dynamics,":[43],"thermostatic":[44],"action":[45],"automation":[48],"system.":[49],"this":[51],"work":[52],"we":[53],"will":[54],"combine":[55],"rule-based":[57],"program":[60,67,85],"with":[61],"learning":[63],"feedback":[64],"that":[68],"can":[69],"operate":[70],"on":[71],"top":[72],"rules.":[75],"We":[76],"demonstrate":[77],"via":[78],"extensive":[79],"simulations":[80],"effectiveness":[82],"for":[86],"intelligent":[87],"heating,":[91],"ventilating":[92],"air":[94],"conditioning":[95],"(HVAC)":[96],"loads":[97],"so":[98],"as":[99],"exploit":[101],"renewable":[102],"energy":[103],"sources,":[104],"while":[105],"taking":[106],"into":[107],"account":[108],"human-related":[109],"constraints":[110],"like":[111],"thermal":[112],"comfort.":[113]},"counts_by_year":[{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}