{"id":"https://openalex.org/W2741235203","doi":"https://doi.org/10.1109/icc.2017.7997410","title":"Optical datacenter networks with elastic optical switches","display_name":"Optical datacenter networks with elastic optical switches","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2741235203","doi":"https://doi.org/10.1109/icc.2017.7997410","mag":"2741235203"},"language":"en","primary_location":{"id":"doi:10.1109/icc.2017.7997410","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2017.7997410","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013035634","display_name":"Wojciech Kabaci\u0144ski","orcid":"https://orcid.org/0000-0001-5244-9967"},"institutions":[{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Wojciech Kabacinski","raw_affiliation_strings":["Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068966089","display_name":"Marek Michalski","orcid":"https://orcid.org/0000-0002-6951-7222"},"institutions":[{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Marek Michalski","raw_affiliation_strings":["Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035385130","display_name":"Remigiusz Rajewski","orcid":"https://orcid.org/0000-0001-8632-9971"},"institutions":[{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Remigiusz Rajewski","raw_affiliation_strings":["Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011374912","display_name":"Mariusz \u017bal","orcid":"https://orcid.org/0000-0002-2579-1502"},"institutions":[{"id":"https://openalex.org/I46597724","display_name":"Pozna\u0144 University of Technology","ror":"https://ror.org/00p7p3302","country_code":"PL","type":"education","lineage":["https://openalex.org/I46597724"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mariusz Zal","raw_affiliation_strings":["Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electronics and Telecommunications, Poznan University of Technology, Poznan, Poland","institution_ids":["https://openalex.org/I46597724"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I46597724"],"apc_list":null,"apc_paid":null,"fwci":1.5488,"has_fulltext":false,"cited_by_count":21,"citation_normalized_percentile":{"value":0.84106519,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10232","display_name":"Optical Network Technologies","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/optical-switch","display_name":"Optical switch","score":0.8287825584411621},{"id":"https://openalex.org/keywords/optical-burst-switching","display_name":"Optical burst switching","score":0.7368341088294983},{"id":"https://openalex.org/keywords/server","display_name":"Server","score":0.6719855666160583},{"id":"https://openalex.org/keywords/blocking","display_name":"Blocking (statistics)","score":0.6566382646560669},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.6533424854278564},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6462938785552979},{"id":"https://openalex.org/keywords/circuit-switching","display_name":"Circuit switching","score":0.6157494187355042},{"id":"https://openalex.org/keywords/optical-performance-monitoring","display_name":"Optical performance monitoring","score":0.5637314319610596},{"id":"https://openalex.org/keywords/optical-cross-connect","display_name":"Optical cross-connect","score":0.5541403889656067},{"id":"https://openalex.org/keywords/3d-optical-data-storage","display_name":"3D optical data storage","score":0.5092605352401733},{"id":"https://openalex.org/keywords/optical-transport-network","display_name":"Optical Transport Network","score":0.5067430138587952},{"id":"https://openalex.org/keywords/lan-switching","display_name":"LAN switching","score":0.485257625579834},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3999713957309723},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.35064220428466797},{"id":"https://openalex.org/keywords/burst-switching","display_name":"Burst switching","score":0.3163735866546631},{"id":"https://openalex.org/keywords/optical-fiber","display_name":"Optical fiber","score":0.23238295316696167},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.22856804728507996},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.1981017291545868},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.17757171392440796},{"id":"https://openalex.org/keywords/wavelength-division-multiplexing","display_name":"Wavelength-division multiplexing","score":0.16921916604042053},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.16376382112503052}],"concepts":[{"id":"https://openalex.org/C101336846","wikidata":"https://www.wikidata.org/wiki/Q17105111","display_name":"Optical switch","level":2,"score":0.8287825584411621},{"id":"https://openalex.org/C197417287","wikidata":"https://www.wikidata.org/wiki/Q7098837","display_name":"Optical burst switching","level":5,"score":0.7368341088294983},{"id":"https://openalex.org/C93996380","wikidata":"https://www.wikidata.org/wiki/Q44127","display_name":"Server","level":2,"score":0.6719855666160583},{"id":"https://openalex.org/C144745244","wikidata":"https://www.wikidata.org/wiki/Q4927286","display_name":"Blocking (statistics)","level":2,"score":0.6566382646560669},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.6533424854278564},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6462938785552979},{"id":"https://openalex.org/C74294265","wikidata":"https://www.wikidata.org/wiki/Q506273","display_name":"Circuit switching","level":2,"score":0.6157494187355042},{"id":"https://openalex.org/C26840048","wikidata":"https://www.wikidata.org/wiki/Q7098880","display_name":"Optical performance monitoring","level":4,"score":0.5637314319610596},{"id":"https://openalex.org/C196129803","wikidata":"https://www.wikidata.org/wiki/Q241448","display_name":"Optical cross-connect","level":3,"score":0.5541403889656067},{"id":"https://openalex.org/C128717455","wikidata":"https://www.wikidata.org/wiki/Q2024185","display_name":"3D optical data storage","level":2,"score":0.5092605352401733},{"id":"https://openalex.org/C70979049","wikidata":"https://www.wikidata.org/wiki/Q51831","display_name":"Optical Transport Network","level":5,"score":0.5067430138587952},{"id":"https://openalex.org/C185498113","wikidata":"https://www.wikidata.org/wiki/Q4503","display_name":"LAN switching","level":5,"score":0.485257625579834},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3999713957309723},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.35064220428466797},{"id":"https://openalex.org/C180026317","wikidata":"https://www.wikidata.org/wiki/Q5000645","display_name":"Burst switching","level":4,"score":0.3163735866546631},{"id":"https://openalex.org/C194232370","wikidata":"https://www.wikidata.org/wiki/Q162","display_name":"Optical fiber","level":2,"score":0.23238295316696167},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.22856804728507996},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.1981017291545868},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.17757171392440796},{"id":"https://openalex.org/C160724564","wikidata":"https://www.wikidata.org/wiki/Q1620670","display_name":"Wavelength-division multiplexing","level":3,"score":0.16921916604042053},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.16376382112503052},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C108921912","wikidata":"https://www.wikidata.org/wiki/Q7834639","display_name":"Transmission delay","level":3,"score":0.0},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icc.2017.7997410","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2017.7997410","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.4099999964237213,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W1535708559","https://openalex.org/W1561268405","https://openalex.org/W1576535065","https://openalex.org/W1973457482","https://openalex.org/W1986975748","https://openalex.org/W2015665441","https://openalex.org/W2019250072","https://openalex.org/W2038916248","https://openalex.org/W2055952492","https://openalex.org/W2062330063","https://openalex.org/W2097926925","https://openalex.org/W2110173188","https://openalex.org/W2118270918","https://openalex.org/W2119638333","https://openalex.org/W2133768407","https://openalex.org/W2148455152","https://openalex.org/W2157614013","https://openalex.org/W2186040286","https://openalex.org/W2284351912","https://openalex.org/W2342718233","https://openalex.org/W2344975244","https://openalex.org/W2415758767","https://openalex.org/W2477228842","https://openalex.org/W2529228963","https://openalex.org/W2562586945","https://openalex.org/W6633482681","https://openalex.org/W6686721096"],"related_works":["https://openalex.org/W2071685753","https://openalex.org/W2169595109","https://openalex.org/W640242547","https://openalex.org/W1485431665","https://openalex.org/W2124251445","https://openalex.org/W1606001471","https://openalex.org/W1641662195","https://openalex.org/W2317012402","https://openalex.org/W2545769589","https://openalex.org/W2001813392"],"abstract_inverted_index":{"Four":[0],"variants":[1],"of":[2,45,49,68,87],"the":[3,46],"optical":[4,14,19],"data":[5,64,81],"center":[6],"network":[7],"architecture":[8],"(DCN1":[9],"-":[10],"DCN4)":[11],"based":[12],"on":[13],"circuit":[15],"switching":[16,20,50,78],"and":[17,35],"elastic":[18],"elements":[21,79],"are":[22,40],"proposed.":[23],"For":[24],"each":[25],"variant":[26,56,73],"theoretical":[27],"limits":[28],"for":[29,61],"non-blocking":[30],"operation":[31],"have":[32],"been":[33],"derived":[34],"proved.":[36],"The":[37],"proposed":[38],"networks":[39],"also":[41],"compared":[42],"in":[43,80],"terms":[44],"required":[47],"number":[48],"elements.":[51],"Our":[52],"results":[53],"show":[54],"that":[55],"DCN1":[57],"is":[58],"more":[59],"appropriate":[60],"very":[62],"small":[63],"centers":[65,82],"with":[66,70,83],"tens":[67],"racks":[69],"servers,":[71],"while":[72],"DCN4":[74],"requires":[75],"much":[76],"fewer":[77],"hundreds":[84],"or":[85],"thousands":[86],"such":[88],"racks.":[89]},"counts_by_year":[{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
