{"id":"https://openalex.org/W1549306173","doi":"https://doi.org/10.1109/icc.2015.7248421","title":"Hierarchical Wireless network design for synchrophasor communication in Distributed Generation grid","display_name":"Hierarchical Wireless network design for synchrophasor communication in Distributed Generation grid","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W1549306173","doi":"https://doi.org/10.1109/icc.2015.7248421","mag":"1549306173"},"language":"en","primary_location":{"id":"doi:10.1109/icc.2015.7248421","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2015.7248421","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://zenodo.org/record/1269983","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5062830296","display_name":"Hamid Gharavi","orcid":"https://orcid.org/0000-0003-3832-488X"},"institutions":[{"id":"https://openalex.org/I1321296531","display_name":"National Institute of Standards and Technology","ror":"https://ror.org/05xpvk416","country_code":"US","type":"funder","lineage":["https://openalex.org/I1321296531","https://openalex.org/I1343035065"]},{"id":"https://openalex.org/I4210167249","display_name":"Network Technologies (United States)","ror":"https://ror.org/05xnsth60","country_code":"US","type":"company","lineage":["https://openalex.org/I4210167249"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Hamid Gharavi","raw_affiliation_strings":["Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA","[Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA]"],"affiliations":[{"raw_affiliation_string":"Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA","institution_ids":["https://openalex.org/I4210167249","https://openalex.org/I1321296531"]},{"raw_affiliation_string":"[Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA]","institution_ids":["https://openalex.org/I1321296531"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101513623","display_name":"Bin Hu","orcid":"https://orcid.org/0000-0002-6336-1650"},"institutions":[{"id":"https://openalex.org/I1321296531","display_name":"National Institute of Standards and Technology","ror":"https://ror.org/05xpvk416","country_code":"US","type":"funder","lineage":["https://openalex.org/I1321296531","https://openalex.org/I1343035065"]},{"id":"https://openalex.org/I4210167249","display_name":"Network Technologies (United States)","ror":"https://ror.org/05xnsth60","country_code":"US","type":"company","lineage":["https://openalex.org/I4210167249"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bin Hu","raw_affiliation_strings":["Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA","[Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA]"],"affiliations":[{"raw_affiliation_string":"Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA","institution_ids":["https://openalex.org/I4210167249","https://openalex.org/I1321296531"]},{"raw_affiliation_string":"[Advanced Network Technologies, National Institute of Standards and Technology, Gaithersburg, USA]","institution_ids":["https://openalex.org/I1321296531"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5062830296"],"corresponding_institution_ids":["https://openalex.org/I1321296531","https://openalex.org/I4210167249"],"apc_list":null,"apc_paid":null,"fwci":0.6006,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.71311864,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":"14","issue":null,"first_page":"808","last_page":"814"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/testbed","display_name":"Testbed","score":0.8402495384216309},{"id":"https://openalex.org/keywords/situation-awareness","display_name":"Situation awareness","score":0.6770008206367493},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6015295386314392},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.5064345598220825},{"id":"https://openalex.org/keywords/software-deployment","display_name":"Software deployment","score":0.47495293617248535},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.47450515627861023},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.4706287384033203},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.4604329466819763},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.44875937700271606},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.44616714119911194},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.435332715511322},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.4278792142868042},{"id":"https://openalex.org/keywords/network-architecture","display_name":"Network architecture","score":0.4120337963104248},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2754507064819336},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.17199140787124634},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.15774914622306824},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08075681328773499}],"concepts":[{"id":"https://openalex.org/C31395832","wikidata":"https://www.wikidata.org/wiki/Q1318674","display_name":"Testbed","level":2,"score":0.8402495384216309},{"id":"https://openalex.org/C145804949","wikidata":"https://www.wikidata.org/wiki/Q478123","display_name":"Situation awareness","level":2,"score":0.6770008206367493},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6015295386314392},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.5064345598220825},{"id":"https://openalex.org/C105339364","wikidata":"https://www.wikidata.org/wiki/Q2297740","display_name":"Software deployment","level":2,"score":0.47495293617248535},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.47450515627861023},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.4706287384033203},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.4604329466819763},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.44875937700271606},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.44616714119911194},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.435332715511322},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.4278792142868042},{"id":"https://openalex.org/C193415008","wikidata":"https://www.wikidata.org/wiki/Q639681","display_name":"Network architecture","level":2,"score":0.4120337963104248},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2754507064819336},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.17199140787124634},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.15774914622306824},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08075681328773499},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C146978453","wikidata":"https://www.wikidata.org/wiki/Q3798668","display_name":"Aerospace engineering","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/icc.2015.7248421","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2015.7248421","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"},{"id":"pmh:oai:zenodo.org:1269983","is_oa":true,"landing_page_url":"https://zenodo.org/record/1269983","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"}],"best_oa_location":{"id":"pmh:oai:zenodo.org:1269983","is_oa":true,"landing_page_url":"https://zenodo.org/record/1269983","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"},"sustainable_development_goals":[{"score":0.6200000047683716,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W1551433093","https://openalex.org/W1709613437","https://openalex.org/W1726571582","https://openalex.org/W1965030196","https://openalex.org/W1970705443","https://openalex.org/W2002348716","https://openalex.org/W2030374597","https://openalex.org/W2041821701","https://openalex.org/W2051005341","https://openalex.org/W2057991655","https://openalex.org/W2063092822","https://openalex.org/W2071942128","https://openalex.org/W2103622721","https://openalex.org/W2107584338","https://openalex.org/W2108713391","https://openalex.org/W2110807014","https://openalex.org/W2119654559","https://openalex.org/W2133691058","https://openalex.org/W2142441939","https://openalex.org/W2150773759","https://openalex.org/W2155833003","https://openalex.org/W2182847438","https://openalex.org/W2540646745","https://openalex.org/W4246404160","https://openalex.org/W6637475830","https://openalex.org/W6676346148","https://openalex.org/W6686096749"],"related_works":["https://openalex.org/W2883256816","https://openalex.org/W2171408034","https://openalex.org/W2071137974","https://openalex.org/W3003320923","https://openalex.org/W4224280502","https://openalex.org/W2106140982","https://openalex.org/W2503196393","https://openalex.org/W2152313554","https://openalex.org/W2064303750","https://openalex.org/W3048672182"],"abstract_inverted_index":{"There":[0],"has":[1],"been":[2],"a":[3,15,28,58,68,79,94,105],"growing":[4],"interest":[5],"in":[6,14,78,86],"the":[7,25,54,60,83,116],"deployment":[8],"of":[9,27,56],"Phasor":[10],"Measurement":[11],"Units":[12],"(PMUs)":[13],"Distributed":[16],"Generation":[17],"(DG)":[18],"grid":[19,51],"system.":[20],"A":[21],"major":[22],"obstacle":[23],"is":[24,89,135],"lack":[26],"communication":[29],"network":[30,70,96,107,141],"infrastructure":[31],"that":[32],"can":[33],"support":[34,72],"phasor":[35],"measurements":[36],"for":[37,47,75,125],"distribution":[38],"area":[39],"monitoring":[40],"as":[41,43,120,122],"well":[42,121],"providing":[44],"sensing":[45],"capabilities":[46,124],"protection":[48],"against":[49],"undesirable":[50],"dynamics.":[52],"In":[53],"absence":[55],"such":[57],"network,":[59],"most":[61],"cost-effective":[62],"solution":[63],"would":[64],"be":[65],"to":[66,71,90,114,138],"consider":[67],"wireless":[69],"centralized":[73],"control":[74,126],"situational":[76],"awareness":[77],"DG":[80],"environment.":[81],"Therefore,":[82],"main":[84],"objective":[85],"this":[87],"paper":[88],"design":[91],"and":[92,127],"implement":[93],"synchrophasor":[95,117],"testbed":[97,134],"using":[98],"Wireless":[99],"LAN":[100],"(WLAN)":[101],"technology.":[102],"Based":[103],"on":[104],"hierarchical":[106,131],"architecture,":[108],"we":[109],"propose":[110],"an":[111],"efficient":[112],"method":[113],"reduce":[115],"data":[118],"bandwidth,":[119],"provide":[123],"management":[128],"at":[129],"each":[130],"level.":[132],"This":[133],"then":[136],"used":[137],"evaluate":[139],"different":[140],"configurations":[142],"under":[143],"various":[144],"test":[145],"conditions.":[146]},"counts_by_year":[{"year":2017,"cited_by_count":3}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}
