{"id":"https://openalex.org/W1482776682","doi":"https://doi.org/10.1109/icc.2015.7248329","title":"Power-efficient base station operation through user QoS-aware adaptive RF chain switching technique","display_name":"Power-efficient base station operation through user QoS-aware adaptive RF chain switching technique","publication_year":2015,"publication_date":"2015-06-01","ids":{"openalex":"https://openalex.org/W1482776682","doi":"https://doi.org/10.1109/icc.2015.7248329","mag":"1482776682"},"language":"en","primary_location":{"id":"doi:10.1109/icc.2015.7248329","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2015.7248329","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078780980","display_name":"Ranjini Guruprasad","orcid":"https://orcid.org/0000-0002-7068-065X"},"institutions":[{"id":"https://openalex.org/I36258959","display_name":"University of California, San Diego","ror":"https://ror.org/0168r3w48","country_code":"US","type":"education","lineage":["https://openalex.org/I36258959"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Ranjini Guruprasad","raw_affiliation_strings":["Dept. of Electrical and Computer Engineering, University of California, San Diego","Mobile Systems Design Lab, Dept. of Electrical and Computer Engineering, University of California, San Diego, USA"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Computer Engineering, University of California, San Diego","institution_ids":["https://openalex.org/I36258959"]},{"raw_affiliation_string":"Mobile Systems Design Lab, Dept. of Electrical and Computer Engineering, University of California, San Diego, USA","institution_ids":["https://openalex.org/I36258959"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034147672","display_name":"Kyuho Son","orcid":"https://orcid.org/0000-0002-2660-4019"},"institutions":[{"id":"https://openalex.org/I4210108985","display_name":"Bellevue Hospital Center","ror":"https://ror.org/01ky34z31","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I1283621791","https://openalex.org/I4210086933","https://openalex.org/I4210108985"]},{"id":"https://openalex.org/I41166544","display_name":"T-Mobile (United States)","ror":"https://ror.org/01w2zpd04","country_code":"US","type":"company","lineage":["https://openalex.org/I41166544"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Kyuho Son","raw_affiliation_strings":["T-Mobile, Bellevue, WA, US","T-Mobile US, Bellevue, WA, USA"],"affiliations":[{"raw_affiliation_string":"T-Mobile, Bellevue, WA, US","institution_ids":["https://openalex.org/I41166544","https://openalex.org/I4210108985"]},{"raw_affiliation_string":"T-Mobile US, Bellevue, WA, USA","institution_ids":["https://openalex.org/I41166544","https://openalex.org/I4210108985"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5105369696","display_name":"Sujit Dey","orcid":"https://orcid.org/0000-0001-9671-3950"},"institutions":[{"id":"https://openalex.org/I36258959","display_name":"University of California, San Diego","ror":"https://ror.org/0168r3w48","country_code":"US","type":"education","lineage":["https://openalex.org/I36258959"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Sujit Dey","raw_affiliation_strings":["Dept. of Electrical and Computer Engineering, University of California, San Diego","Mobile Systems Design Lab, Dept. of Electrical and Computer Engineering, University of California, San Diego, USA"],"affiliations":[{"raw_affiliation_string":"Dept. of Electrical and Computer Engineering, University of California, San Diego","institution_ids":["https://openalex.org/I36258959"]},{"raw_affiliation_string":"Mobile Systems Design Lab, Dept. of Electrical and Computer Engineering, University of California, San Diego, USA","institution_ids":["https://openalex.org/I36258959"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5078780980"],"corresponding_institution_ids":["https://openalex.org/I36258959"],"apc_list":null,"apc_paid":null,"fwci":0.7891,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.74827936,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"61","issue":null,"first_page":"244","last_page":"250"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10148","display_name":"Advanced MIMO Systems Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10575","display_name":"Wireless Communication Networks Research","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.8151615262031555},{"id":"https://openalex.org/keywords/base-station","display_name":"Base station","score":0.7630265951156616},{"id":"https://openalex.org/keywords/block-error-rate","display_name":"Block Error Rate","score":0.7432886362075806},{"id":"https://openalex.org/keywords/throughput","display_name":"Throughput","score":0.6449456214904785},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.6279022097587585},{"id":"https://openalex.org/keywords/radio-frequency","display_name":"Radio frequency","score":0.6198277473449707},{"id":"https://openalex.org/keywords/heuristic","display_name":"Heuristic","score":0.5950284004211426},{"id":"https://openalex.org/keywords/block","display_name":"Block (permutation group theory)","score":0.4923793077468872},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.479716956615448},{"id":"https://openalex.org/keywords/user-equipment","display_name":"User equipment","score":0.4348060190677643},{"id":"https://openalex.org/keywords/power-consumption","display_name":"Power consumption","score":0.43097367882728577},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.42475426197052},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4169475734233856},{"id":"https://openalex.org/keywords/telecommunications-link","display_name":"Telecommunications link","score":0.33772167563438416},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3271982669830322},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.18191176652908325},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14413735270500183},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.12836682796478271},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.07070177793502808}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.8151615262031555},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.7630265951156616},{"id":"https://openalex.org/C2776639698","wikidata":"https://www.wikidata.org/wiki/Q4927140","display_name":"Block Error Rate","level":3,"score":0.7432886362075806},{"id":"https://openalex.org/C157764524","wikidata":"https://www.wikidata.org/wiki/Q1383412","display_name":"Throughput","level":3,"score":0.6449456214904785},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.6279022097587585},{"id":"https://openalex.org/C74064498","wikidata":"https://www.wikidata.org/wiki/Q3396184","display_name":"Radio frequency","level":2,"score":0.6198277473449707},{"id":"https://openalex.org/C173801870","wikidata":"https://www.wikidata.org/wiki/Q201413","display_name":"Heuristic","level":2,"score":0.5950284004211426},{"id":"https://openalex.org/C2777210771","wikidata":"https://www.wikidata.org/wiki/Q4927124","display_name":"Block (permutation group theory)","level":2,"score":0.4923793077468872},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.479716956615448},{"id":"https://openalex.org/C2781327853","wikidata":"https://www.wikidata.org/wiki/Q3552547","display_name":"User equipment","level":3,"score":0.4348060190677643},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.43097367882728577},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.42475426197052},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4169475734233856},{"id":"https://openalex.org/C138660444","wikidata":"https://www.wikidata.org/wiki/Q5607897","display_name":"Telecommunications link","level":2,"score":0.33772167563438416},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3271982669830322},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.18191176652908325},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14413735270500183},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.12836682796478271},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.07070177793502808},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icc.2015.7248329","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2015.7248329","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1971046365","https://openalex.org/W1989095939","https://openalex.org/W1993253078","https://openalex.org/W2001139053","https://openalex.org/W2021906103","https://openalex.org/W2030008377","https://openalex.org/W2035059403","https://openalex.org/W2093945752","https://openalex.org/W2097850831","https://openalex.org/W2098163028","https://openalex.org/W2098563066","https://openalex.org/W2108333571","https://openalex.org/W2110519532","https://openalex.org/W2144239375","https://openalex.org/W2313908459","https://openalex.org/W4293579770","https://openalex.org/W6628812410","https://openalex.org/W6699183330"],"related_works":["https://openalex.org/W4365807906","https://openalex.org/W2157864637","https://openalex.org/W4223416141","https://openalex.org/W2105999282","https://openalex.org/W3006920049","https://openalex.org/W1922070205","https://openalex.org/W2136902318","https://openalex.org/W3036314667","https://openalex.org/W2957675536","https://openalex.org/W4226210192"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3,40,79],"develop":[4],"a":[5,81],"user":[6],"Quality":[7],"of":[8,24,34,61,64,72,91,114,127],"Service":[9],"(QoS)":[10],"aware":[11],"adaptive":[12],"Radio":[13],"Frequency":[14],"(RF)":[15],"chain":[16],"switching":[17],"technique":[18],"that":[19,102],"dynamically":[20],"adapts":[21],"the":[22,30,35,48,53,62,65,69,89,103,115,119,125],"number":[23,90],"active":[25,92],"RF":[26,93,128],"chains":[27,129],"to":[28,46,68,118],"minimize":[29,47],"total":[31,49,111],"power":[32,50,112],"consumption":[33,51,113],"base":[36],"station":[37],"(BS).":[38],"Specifically,":[39],"first":[41],"formulate":[42],"an":[43,76],"optimization":[44],"problem":[45],"under":[52],"throughput":[54],"and":[55,96],"Block":[56],"Error":[57],"Rate":[58],"(BLER)":[59],"requirements":[60],"users":[63],"BS.":[66],"Due":[67],"prohibitive":[70],"complexity":[71],"exhaustive":[73],"algorithm":[74,105],"achieving":[75],"optimal":[77],"solution,":[78],"propose":[80],"practically":[82],"implementable":[83],"heuristic":[84],"algorithm,":[85],"which":[86],"jointly":[87],"optimizes":[88],"chains,":[94],"frequency":[95],"time":[97],"resources.":[98],"Simulation":[99],"results":[100],"demonstrate":[101],"proposed":[104],"can":[106],"achieve":[107],"significant":[108],"savings":[109],"in":[110],"BSs":[116],"compared":[117],"conventional":[120],"static":[121],"All-On":[122],"scheme":[123],"wherein":[124],"activity":[126],"is":[130],"not":[131],"adapted.":[132]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
