{"id":"https://openalex.org/W2068351198","doi":"https://doi.org/10.1109/icc.2012.6364258","title":"A secure and efficient scheme for machine-to-machine communications in smart grid","display_name":"A secure and efficient scheme for machine-to-machine communications in smart grid","publication_year":2012,"publication_date":"2012-06-01","ids":{"openalex":"https://openalex.org/W2068351198","doi":"https://doi.org/10.1109/icc.2012.6364258","mag":"2068351198"},"language":"en","primary_location":{"id":"doi:10.1109/icc.2012.6364258","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2012.6364258","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101602641","display_name":"Yan Ye","orcid":"https://orcid.org/0000-0002-7278-0822"},"institutions":[{"id":"https://openalex.org/I114395901","display_name":"University of Nebraska\u2013Lincoln","ror":"https://ror.org/043mer456","country_code":"US","type":"education","lineage":["https://openalex.org/I114395901"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Ye Yan","raw_affiliation_strings":["Department of Computer and Electronics Engineering, University of Nebraska, Lincoln, USA","Department of Computer and Electronics Engineering University of Nebraska-Lincoln"],"affiliations":[{"raw_affiliation_string":"Department of Computer and Electronics Engineering, University of Nebraska, Lincoln, USA","institution_ids":["https://openalex.org/I114395901"]},{"raw_affiliation_string":"Department of Computer and Electronics Engineering University of Nebraska-Lincoln","institution_ids":["https://openalex.org/I114395901"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073527013","display_name":"Yi Qian","orcid":"https://orcid.org/0000-0001-5671-916X"},"institutions":[{"id":"https://openalex.org/I114395901","display_name":"University of Nebraska\u2013Lincoln","ror":"https://ror.org/043mer456","country_code":"US","type":"education","lineage":["https://openalex.org/I114395901"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yi Qian","raw_affiliation_strings":["Department of Computer and Electronics Engineering, University of Nebraska, Lincoln, USA","Department of Computer and Electronics Engineering University of Nebraska-Lincoln"],"affiliations":[{"raw_affiliation_string":"Department of Computer and Electronics Engineering, University of Nebraska, Lincoln, USA","institution_ids":["https://openalex.org/I114395901"]},{"raw_affiliation_string":"Department of Computer and Electronics Engineering University of Nebraska-Lincoln","institution_ids":["https://openalex.org/I114395901"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057118326","display_name":"Rose Qingyang Hu","orcid":"https://orcid.org/0000-0002-1571-3631"},"institutions":[{"id":"https://openalex.org/I121980950","display_name":"Utah State University","ror":"https://ror.org/00h6set76","country_code":"US","type":"education","lineage":["https://openalex.org/I121980950"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Rose Qingyang Hu","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Utah State University, USA","Department of Electrical and Computer Engineering, Utah State University"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Utah State University, USA","institution_ids":["https://openalex.org/I121980950"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Utah State University","institution_ids":["https://openalex.org/I121980950"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101602641"],"corresponding_institution_ids":["https://openalex.org/I114395901"],"apc_list":null,"apc_paid":null,"fwci":1.6891,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.86778595,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"167","last_page":"172"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9955000281333923,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.8493466377258301},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7714303731918335},{"id":"https://openalex.org/keywords/machine-to-machine","display_name":"Machine to machine","score":0.7226459383964539},{"id":"https://openalex.org/keywords/initialization","display_name":"Initialization","score":0.6055628061294556},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.5777787566184998},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.5713151693344116},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.5008461475372314},{"id":"https://openalex.org/keywords/code-division-multiple-access","display_name":"Code division multiple access","score":0.48614785075187683},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.4587329924106598},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.44776707887649536},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4432445466518402},{"id":"https://openalex.org/keywords/communications-security","display_name":"Communications security","score":0.4315982460975647},{"id":"https://openalex.org/keywords/authentication","display_name":"Authentication (law)","score":0.422076553106308},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.2890435457229614},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.2315833568572998},{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.1568318009376526},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15013939142227173},{"id":"https://openalex.org/keywords/encryption","display_name":"Encryption","score":0.09285110235214233}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.8493466377258301},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7714303731918335},{"id":"https://openalex.org/C76763059","wikidata":"https://www.wikidata.org/wiki/Q251072","display_name":"Machine to machine","level":3,"score":0.7226459383964539},{"id":"https://openalex.org/C114466953","wikidata":"https://www.wikidata.org/wiki/Q6034165","display_name":"Initialization","level":2,"score":0.6055628061294556},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.5777787566184998},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.5713151693344116},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.5008461475372314},{"id":"https://openalex.org/C47696715","wikidata":"https://www.wikidata.org/wiki/Q233394","display_name":"Code division multiple access","level":2,"score":0.48614785075187683},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4587329924106598},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.44776707887649536},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4432445466518402},{"id":"https://openalex.org/C151423352","wikidata":"https://www.wikidata.org/wiki/Q5154228","display_name":"Communications security","level":3,"score":0.4315982460975647},{"id":"https://openalex.org/C148417208","wikidata":"https://www.wikidata.org/wiki/Q4825882","display_name":"Authentication (law)","level":2,"score":0.422076553106308},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.2890435457229614},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.2315833568572998},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.1568318009376526},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15013939142227173},{"id":"https://openalex.org/C148730421","wikidata":"https://www.wikidata.org/wiki/Q141090","display_name":"Encryption","level":2,"score":0.09285110235214233},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icc.2012.6364258","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icc.2012.6364258","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE International Conference on Communications (ICC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6399999856948853,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W410025","https://openalex.org/W1597087347","https://openalex.org/W1973919908","https://openalex.org/W1975153313","https://openalex.org/W1990428236","https://openalex.org/W2024619974","https://openalex.org/W2030617739","https://openalex.org/W2054538149","https://openalex.org/W2069304655","https://openalex.org/W2100955315","https://openalex.org/W2108355831","https://openalex.org/W2110817709","https://openalex.org/W2119290091","https://openalex.org/W2123910460","https://openalex.org/W2140656373","https://openalex.org/W2146535370","https://openalex.org/W2162297215","https://openalex.org/W2478708596","https://openalex.org/W6635850491","https://openalex.org/W6643706280"],"related_works":["https://openalex.org/W3204184292","https://openalex.org/W2384104878","https://openalex.org/W3176564347","https://openalex.org/W1985458517","https://openalex.org/W2360352189","https://openalex.org/W2097422349","https://openalex.org/W2314106443","https://openalex.org/W2207495662","https://openalex.org/W163279519","https://openalex.org/W3028730261"],"abstract_inverted_index":{"Smart":[0],"grid":[1,28,38,123],"uses":[2],"machine-to-machine":[3],"(M2M)":[4],"communication":[5,20],"infrastructures":[6],"and":[7,15,75,91,111,119],"advanced":[8,62],"control":[9],"techniques":[10],"for":[11,26,60,115],"improved":[12],"power":[13],"distributions":[14],"management.":[16],"Different":[17],"types":[18],"of":[19,48,94,107],"schemes":[21],"could":[22],"possibly":[23],"be":[24,33],"used":[25],"smart":[27,37,67,122],"applications,":[29],"but":[30],"need":[31],"to":[32],"further":[34],"explored":[35],"in":[36,57,66,80,121],"application":[39],"scenarios.":[40],"In":[41],"this":[42],"paper,":[43],"we":[44],"present":[45],"the":[46,61,71,81,89,95,105,108,112,116],"utilization":[47],"a":[49],"zero":[50],"correlation":[51],"zone":[52],"(ZCZ)":[53],"CDMA":[54,98],"based":[55,99],"scheme":[56,110],"M2M":[58,124],"communications":[59],"metering":[63],"infrastructure":[64],"(AMI)":[65],"grid.":[68],"We":[69,87],"design":[70],"ZCZ":[72,97],"code":[73],"generation":[74],"distribution":[76],"through":[77],"mutual":[78],"authentication":[79],"initialization":[82],"procedure":[83],"before":[84],"data":[85],"transmission.":[86],"examine":[88],"security":[90,118],"efficiency":[92],"aspects":[93],"proposed":[96,109],"scheme.":[100],"The":[101],"paper":[102],"concludes":[103],"with":[104],"comparison":[106],"legacy":[113],"approach":[114],"system":[117],"performance":[120],"communications.":[125]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
