{"id":"https://openalex.org/W2584333732","doi":"https://doi.org/10.1109/icarcv.2016.7838703","title":"Data-driven fault-tolerant control for energy efficiency in a multi-zone building","display_name":"Data-driven fault-tolerant control for energy efficiency in a multi-zone building","publication_year":2016,"publication_date":"2016-11-01","ids":{"openalex":"https://openalex.org/W2584333732","doi":"https://doi.org/10.1109/icarcv.2016.7838703","mag":"2584333732"},"language":"en","primary_location":{"id":"doi:10.1109/icarcv.2016.7838703","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2016.7838703","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 14th International Conference on Control, Automation, Robotics and Vision (ICARCV)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010806251","display_name":"Tushar Jain","orcid":"https://orcid.org/0000-0003-2300-1375"},"institutions":[{"id":"https://openalex.org/I9579091","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34","country_code":"IN","type":"education","lineage":["https://openalex.org/I9579091"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Tushar Jain","raw_affiliation_strings":["Indian Institute of Technology Mandi, School of Computing and Electrical Engineering, VPO Kamand, Himachal Pradesh, India"],"affiliations":[{"raw_affiliation_string":"Indian Institute of Technology Mandi, School of Computing and Electrical Engineering, VPO Kamand, Himachal Pradesh, India","institution_ids":["https://openalex.org/I9579091"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031854085","display_name":"Joseph J. Yam\u00e9","orcid":"https://orcid.org/0000-0002-4349-6240"},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I90183372","display_name":"Universit\u00e9 de Lorraine","ror":"https://ror.org/04vfs2w97","country_code":"FR","type":"education","lineage":["https://openalex.org/I90183372"]},{"id":"https://openalex.org/I4210110792","display_name":"Centre de Recherche en Automatique de Nancy","ror":"https://ror.org/022r5hc56","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210099203","https://openalex.org/I4210100260","https://openalex.org/I4210110792","https://openalex.org/I4210159245","https://openalex.org/I90183372"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Joseph J. Yame","raw_affiliation_strings":["Universit\u00e9 de Lorraine, Centre de Recherche en Automatique de Nancy, CNRS, Vandoeuvre-l\u00e8s-Nancy, France"],"affiliations":[{"raw_affiliation_string":"Universit\u00e9 de Lorraine, Centre de Recherche en Automatique de Nancy, CNRS, Vandoeuvre-l\u00e8s-Nancy, France","institution_ids":["https://openalex.org/I4210110792","https://openalex.org/I90183372","https://openalex.org/I1294671590"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107837721","display_name":"Dominique Sauter","orcid":null},"institutions":[{"id":"https://openalex.org/I1294671590","display_name":"Centre National de la Recherche Scientifique","ror":"https://ror.org/02feahw73","country_code":"FR","type":"funder","lineage":["https://openalex.org/I1294671590"]},{"id":"https://openalex.org/I90183372","display_name":"Universit\u00e9 de Lorraine","ror":"https://ror.org/04vfs2w97","country_code":"FR","type":"education","lineage":["https://openalex.org/I90183372"]},{"id":"https://openalex.org/I4210110792","display_name":"Centre de Recherche en Automatique de Nancy","ror":"https://ror.org/022r5hc56","country_code":"FR","type":"facility","lineage":["https://openalex.org/I1294671590","https://openalex.org/I1294671590","https://openalex.org/I4210099203","https://openalex.org/I4210100260","https://openalex.org/I4210110792","https://openalex.org/I4210159245","https://openalex.org/I90183372"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Dominique Sauter","raw_affiliation_strings":["Universit\u00e9 de Lorraine, Centre de Recherche en Automatique de Nancy, CNRS, Vandoeuvre-l\u00e8s-Nancy, France"],"affiliations":[{"raw_affiliation_string":"Universit\u00e9 de Lorraine, Centre de Recherche en Automatique de Nancy, CNRS, Vandoeuvre-l\u00e8s-Nancy, France","institution_ids":["https://openalex.org/I4210110792","https://openalex.org/I90183372","https://openalex.org/I1294671590"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5010806251"],"corresponding_institution_ids":["https://openalex.org/I9579091"],"apc_list":null,"apc_paid":null,"fwci":0.3049,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.68609854,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9962999820709229,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9789999723434448,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/variable-air-volume","display_name":"Variable air volume","score":0.9025553464889526},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.7105522155761719},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.5675506591796875},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5264193415641785},{"id":"https://openalex.org/keywords/damper","display_name":"Damper","score":0.5075663328170776},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.5060171484947205},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.5009586811065674},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.4997975826263428},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.4852418899536133},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.460308313369751},{"id":"https://openalex.org/keywords/thermal","display_name":"Thermal","score":0.44491779804229736},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.42603030800819397},{"id":"https://openalex.org/keywords/volume","display_name":"Volume (thermodynamics)","score":0.4224255383014679},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.41840681433677673},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4104262590408325},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.38003629446029663},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.35402166843414307},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31325891613960266},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.12957173585891724},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.12499547004699707},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.09272855520248413},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.08898329734802246}],"concepts":[{"id":"https://openalex.org/C51176869","wikidata":"https://www.wikidata.org/wiki/Q7915706","display_name":"Variable air volume","level":3,"score":0.9025553464889526},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.7105522155761719},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.5675506591796875},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5264193415641785},{"id":"https://openalex.org/C140096630","wikidata":"https://www.wikidata.org/wiki/Q3423628","display_name":"Damper","level":2,"score":0.5075663328170776},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5060171484947205},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.5009586811065674},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.4997975826263428},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.4852418899536133},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.460308313369751},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.44491779804229736},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.42603030800819397},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.4224255383014679},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.41840681433677673},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4104262590408325},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.38003629446029663},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.35402166843414307},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31325891613960266},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.12957173585891724},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.12499547004699707},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.09272855520248413},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.08898329734802246},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icarcv.2016.7838703","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2016.7838703","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 14th International Conference on Control, Automation, Robotics and Vision (ICARCV)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320326797","display_name":"Indian Institute of Technology Mandi","ror":"https://ror.org/05r9r2f34"},{"id":"https://openalex.org/F4320338367","display_name":"FP7 Nanosciences, Nanotechnologies, Materials and new Production Technologies","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W598648183","https://openalex.org/W1579424694","https://openalex.org/W2018842385","https://openalex.org/W2032021541","https://openalex.org/W2055085275","https://openalex.org/W2063965043","https://openalex.org/W2083761591","https://openalex.org/W2091287081","https://openalex.org/W2115484656","https://openalex.org/W2117324370","https://openalex.org/W2146560209","https://openalex.org/W2171837338","https://openalex.org/W2496953169","https://openalex.org/W2738635245","https://openalex.org/W4242398744"],"related_works":["https://openalex.org/W2360486038","https://openalex.org/W2553289208","https://openalex.org/W2360760451","https://openalex.org/W121233632","https://openalex.org/W2766299428","https://openalex.org/W2370199625","https://openalex.org/W2385060786","https://openalex.org/W2376699905","https://openalex.org/W4289768951","https://openalex.org/W2326668440"],"abstract_inverted_index":{"Variable":[0],"air":[1,43],"volume":[2],"(VAV)":[3],"air-conditioning":[4],"system":[5,32,74,101],"is":[6,33,112,119,129,137,154],"considered":[7],"an":[8,47],"energy-efficient":[9],"solution":[10],"for":[11,97],"multi-zones":[12],"building,":[13],"which":[14],"can":[15],"meet":[16],"the":[17,54,59,68,72,109,115,134,141,146,151],"stringent":[18],"cooling":[19],"and":[20,62],"heating":[21],"demands":[22],"of":[23,40,71,108,126,133,150,159],"occupants":[24],"within":[25,30,102],"individual":[26],"zones.":[27],"The":[28,106,131,148],"role":[29],"this":[31,83,95,127],"to":[34,78],"feed":[35],"zones":[36],"with":[37],"varying":[38],"flow":[39],"constant":[41],"temperature":[42],"independently":[44],"supplied":[45],"by":[46,145],"air-handling":[48],"unit.":[49],"A":[50],"fault":[51],"appearing":[52],"in":[53,94,121,161],"VAV":[55,99],"damper":[56],"deteriorates":[57],"severely":[58],"control":[60,91],"performance":[61],"consequently,":[63],"would":[64],"not":[65],"only":[66],"affect":[67],"energy":[69],"efficiency":[70],"overall":[73],"but":[75],"also":[76],"lead":[77],"occupant":[79],"discomfort.":[80],"To":[81],"circumvent":[82],"issue,":[84],"we":[85],"present":[86],"a":[87,98,103,157,162],"novel":[88],"data-driven":[89],"fault-tolerant":[90],"(FTC)":[92],"scheme":[93,136,153],"paper":[96],"thermal":[100,116],"multi-zone":[104],"building.":[105,164],"novelty":[107],"proposed":[110],"strategy":[111],"that":[113],"neither":[114],"dynamical":[117],"model":[118,128],"used":[120],"real-time,":[122],"nor":[123],"online":[124,142],"identification":[125],"required.":[130],"design":[132],"FTC":[135],"solely":[138],"based":[139],"on":[140,156],"data":[143],"generated":[144],"process.":[147],"effectiveness":[149],"developed":[152],"demonstrated":[155],"case-study":[158],"two-zones":[160],"multi-storey":[163]},"counts_by_year":[{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
