{"id":"https://openalex.org/W2156035301","doi":"https://doi.org/10.1109/icarcv.2010.5707356","title":"Reactive power-voltage integrated control method based on MCR","display_name":"Reactive power-voltage integrated control method based on MCR","publication_year":2010,"publication_date":"2010-12-01","ids":{"openalex":"https://openalex.org/W2156035301","doi":"https://doi.org/10.1109/icarcv.2010.5707356","mag":"2156035301"},"language":"en","primary_location":{"id":"doi:10.1109/icarcv.2010.5707356","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2010.5707356","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 11th International Conference on Control Automation Robotics &amp; Vision","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101958099","display_name":"Jing Dai","orcid":"https://orcid.org/0000-0002-3273-8881"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jing Dai","raw_affiliation_strings":["Inspection and Test Center of Electrical Equipment, State Grid Electric Power Research Institute, Wuhan, China"],"affiliations":[{"raw_affiliation_string":"Inspection and Test Center of Electrical Equipment, State Grid Electric Power Research Institute, Wuhan, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100384854","display_name":"Jun Wang","orcid":"https://orcid.org/0000-0003-0416-2325"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jun Wang","raw_affiliation_strings":["Production & Technology Department, Hubei Electric Power Testing and Research Institute, Wuhan, China"],"affiliations":[{"raw_affiliation_string":"Production & Technology Department, Hubei Electric Power Testing and Research Institute, Wuhan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066211201","display_name":"Li Wan","orcid":"https://orcid.org/0000-0003-3663-8498"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li Wan","raw_affiliation_strings":["Production & Technology Department, Hubei Electric Power Testing and Research Institute, Wuhan, China"],"affiliations":[{"raw_affiliation_string":"Production & Technology Department, Hubei Electric Power Testing and Research Institute, Wuhan, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100443994","display_name":"Dan Chen","orcid":"https://orcid.org/0000-0002-1394-310X"},"institutions":[{"id":"https://openalex.org/I4387152367","display_name":"State Grid Nanjing Power Supply Company (China)","ror":"https://ror.org/00emjrx81","country_code":null,"type":"company","lineage":["https://openalex.org/I4387152367"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dan Chen","raw_affiliation_strings":["Production & Technology Department, Nanning Power Supply Company, Nanning, China"],"affiliations":[{"raw_affiliation_string":"Production & Technology Department, Nanning Power Supply Company, Nanning, China","institution_ids":["https://openalex.org/I4387152367"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072393581","display_name":"Xiaosheng Huang","orcid":"https://orcid.org/0000-0003-1160-585X"},"institutions":[{"id":"https://openalex.org/I4387152367","display_name":"State Grid Nanjing Power Supply Company (China)","ror":"https://ror.org/00emjrx81","country_code":null,"type":"company","lineage":["https://openalex.org/I4387152367"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaosheng Huang","raw_affiliation_strings":["Production & Technology Department, Nanning Power Supply Company, Nanning, China"],"affiliations":[{"raw_affiliation_string":"Production & Technology Department, Nanning Power Supply Company, Nanning, China","institution_ids":["https://openalex.org/I4387152367"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049963367","display_name":"Wenjun Zeng","orcid":"https://orcid.org/0000-0003-2531-3137"},"institutions":[{"id":"https://openalex.org/I196699116","display_name":"Wuhan University of Technology","ror":"https://ror.org/03fe7t173","country_code":"CN","type":"education","lineage":["https://openalex.org/I196699116"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenjun Zeng","raw_affiliation_strings":["College of Electrical Engineering, Wuhan University of Technology, Wuhan, China"],"affiliations":[{"raw_affiliation_string":"College of Electrical Engineering, Wuhan University of Technology, Wuhan, China","institution_ids":["https://openalex.org/I196699116"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5101958099"],"corresponding_institution_ids":["https://openalex.org/I17442442"],"apc_list":null,"apc_paid":null,"fwci":4.491,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.94392438,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"24","issue":null,"first_page":"727","last_page":"731"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14392","display_name":"Geoscience and Mining Technology","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14392","display_name":"Geoscience and Mining Technology","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9733999967575073,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9714000225067139,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.8482908606529236},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.8223531246185303},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.7101888060569763},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.6447104215621948},{"id":"https://openalex.org/keywords/volt-ampere-reactive","display_name":"Volt-ampere reactive","score":0.5796153545379639},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5681567788124084},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5386836528778076},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.5080571174621582},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4962072968482971},{"id":"https://openalex.org/keywords/power-control","display_name":"Power control","score":0.4730493128299713},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4568822979927063},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4387798011302948},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3514671325683594},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.29508471488952637},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2542020380496979},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.07015565037727356}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8482908606529236},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.8223531246185303},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.7101888060569763},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.6447104215621948},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.5796153545379639},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5681567788124084},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5386836528778076},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.5080571174621582},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4962072968482971},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4730493128299713},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4568822979927063},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4387798011302948},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3514671325683594},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.29508471488952637},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2542020380496979},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.07015565037727356},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icarcv.2010.5707356","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2010.5707356","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 11th International Conference on Control Automation Robotics &amp; Vision","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1918355989","https://openalex.org/W1997153429","https://openalex.org/W2107962568","https://openalex.org/W2382400761","https://openalex.org/W2391689255"],"related_works":["https://openalex.org/W2740618342","https://openalex.org/W3019765971","https://openalex.org/W2034600866","https://openalex.org/W4221095389","https://openalex.org/W4284711461","https://openalex.org/W4376457885","https://openalex.org/W2393545836","https://openalex.org/W2383413209","https://openalex.org/W3003861339","https://openalex.org/W2165471520"],"abstract_inverted_index":{"In":[0],"power":[1,12,23,40,56,68,82,108,123],"system,":[2],"the":[3,19,26,36,42,46,63,75,87,89,99,118],"voltage":[4,110],"pulsation":[5],"and":[6,28,69,83,97,109],"deficiency":[7],"or":[8],"surplus":[9],"of":[10,21,31,38,48,55,66,77,80,91,106,120],"reactive":[11,39,67,81,107,122],"will":[13],"have":[14],"a":[15,103],"great":[16],"effect":[17],"on":[18,112],"quality":[20,54],"electric":[22],"supply.":[24],"Through":[25],"appropriate":[27],"effective":[29],"way":[30],"compensation,":[32],"we":[33],"can":[34,58],"keep":[35],"balance":[37],"in":[41,95],"maximum":[43],"degree":[44],"by":[45,62],"maintenance":[47],"acceptable":[49],"voltage.":[50,70],"That's":[51],"to":[52,116],"say,":[53],"supply":[57],"be":[59],"improved":[60],"greatly":[61],"synthetic":[64,78],"compensation":[65,79],"This":[71],"paper":[72],"firstly":[73],"describes":[74],"principles":[76],"voltage,":[84],"then":[85],"introduces":[86],"analyzes":[88],"principle":[90],"magnetically":[92],"controlled":[93],"reactor-MCR":[94],"detail":[96],"derives":[98],"characteristics,":[100],"lastly":[101],"designs":[102],"controlling":[104],"strategy":[105],"based":[111],"MCR,":[113],"so":[114],"as":[115],"achieve":[117],"goal":[119],"dynamic":[121],"compensation.":[124]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
