{"id":"https://openalex.org/W2111580845","doi":"https://doi.org/10.1109/icarcv.2008.4795516","title":"Detecting load failures using the induction motor as a transducer","display_name":"Detecting load failures using the induction motor as a transducer","publication_year":2008,"publication_date":"2008-12-01","ids":{"openalex":"https://openalex.org/W2111580845","doi":"https://doi.org/10.1109/icarcv.2008.4795516","mag":"2111580845"},"language":"en","primary_location":{"id":"doi:10.1109/icarcv.2008.4795516","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2008.4795516","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 10th International Conference on Control, Automation, Robotics and Vision","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064941202","display_name":"Erik Leandro Bonaldi","orcid":"https://orcid.org/0000-0003-4350-9248"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"E.L. Bonaldi","raw_affiliation_strings":["PS Solutions, Itajuba, Brazil","PS Solutions, Itajuba"],"affiliations":[{"raw_affiliation_string":"PS Solutions, Itajuba, Brazil","institution_ids":[]},{"raw_affiliation_string":"PS Solutions, Itajuba","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049531400","display_name":"Levy E. L. de Oliveira","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"L.E.L. Oliveira","raw_affiliation_strings":["PS Solutions, Itajuba, Brazil","PS Solutions, Itajuba"],"affiliations":[{"raw_affiliation_string":"PS Solutions, Itajuba, Brazil","institution_ids":[]},{"raw_affiliation_string":"PS Solutions, Itajuba","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029514241","display_name":"Jonas Guedes Borges da Silva","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. G. Borges da Silva","raw_affiliation_strings":["PS Solutions, Itajuba, Brazil","PS Solutions, Itajuba"],"affiliations":[{"raw_affiliation_string":"PS Solutions, Itajuba, Brazil","institution_ids":[]},{"raw_affiliation_string":"PS Solutions, Itajuba","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086956726","display_name":"Germano Lambert\u2010Torres","orcid":"https://orcid.org/0000-0003-3789-4696"},"institutions":[{"id":"https://openalex.org/I8165072","display_name":"Universidade Federal de Itajub\u00e1","ror":"https://ror.org/00235nr42","country_code":"BR","type":"education","lineage":["https://openalex.org/I8165072"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"G. Lambert-Torres","raw_affiliation_strings":["Itajuba Federal University, Itajuba, Brazil","Itajuba Fed. Univ., Itajuba"],"affiliations":[{"raw_affiliation_string":"Itajuba Federal University, Itajuba, Brazil","institution_ids":["https://openalex.org/I8165072"]},{"raw_affiliation_string":"Itajuba Fed. Univ., Itajuba","institution_ids":["https://openalex.org/I8165072"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034637498","display_name":"L.E. Borges da Silva","orcid":null},"institutions":[{"id":"https://openalex.org/I8165072","display_name":"Universidade Federal de Itajub\u00e1","ror":"https://ror.org/00235nr42","country_code":"BR","type":"education","lineage":["https://openalex.org/I8165072"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"L.E. Borges da Silva","raw_affiliation_strings":["Itajuba Federal University, Itajuba, Brazil","Itajuba Fed. Univ., Itajuba"],"affiliations":[{"raw_affiliation_string":"Itajuba Federal University, Itajuba, Brazil","institution_ids":["https://openalex.org/I8165072"]},{"raw_affiliation_string":"Itajuba Fed. Univ., Itajuba","institution_ids":["https://openalex.org/I8165072"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5064941202"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.09503042,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"196","last_page":"199"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9894000291824341,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9850000143051147,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.8561736941337585},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.8124866485595703},{"id":"https://openalex.org/keywords/signature","display_name":"Signature (topology)","score":0.6440926194190979},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5628629922866821},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4869931638240814},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4827350974082947},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3570657968521118},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3081747889518738},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.239432692527771},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.10531076788902283},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.0893051028251648},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.07485908269882202}],"concepts":[{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.8561736941337585},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.8124866485595703},{"id":"https://openalex.org/C2779696439","wikidata":"https://www.wikidata.org/wiki/Q7512811","display_name":"Signature (topology)","level":2,"score":0.6440926194190979},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5628629922866821},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4869931638240814},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4827350974082947},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3570657968521118},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3081747889518738},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.239432692527771},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.10531076788902283},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0893051028251648},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.07485908269882202},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icarcv.2008.4795516","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icarcv.2008.4795516","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2008 10th International Conference on Control, Automation, Robotics and Vision","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5299999713897705,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321091","display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","ror":"https://ror.org/00x0ma614"},{"id":"https://openalex.org/F4320322980","display_name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado de Minas Gerais","ror":"https://ror.org/00nc55f03"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1855755795","https://openalex.org/W1904958519","https://openalex.org/W1966796337","https://openalex.org/W2026550072","https://openalex.org/W2108744642","https://openalex.org/W2109725353","https://openalex.org/W2132265582","https://openalex.org/W2135170300","https://openalex.org/W2136764259","https://openalex.org/W2141728955","https://openalex.org/W2170929448","https://openalex.org/W4232447824","https://openalex.org/W6679957647"],"related_works":["https://openalex.org/W2012283803","https://openalex.org/W4384820447","https://openalex.org/W2072454424","https://openalex.org/W2117438306","https://openalex.org/W2185942010","https://openalex.org/W2260725127","https://openalex.org/W2004297762","https://openalex.org/W1992056405","https://openalex.org/W1966826629","https://openalex.org/W2132265582"],"abstract_inverted_index":{"This":[0],"work":[1],"shows":[2,63],"the":[3,15,31,39,44,51,55,64,67],"feasibility":[4],"of":[5,41,66],"detecting":[6],"load":[7],"mechanical":[8],"failures":[9],"in":[10,43,54],"drive":[11],"train":[12],"by":[13],"using":[14],"induction":[16],"motor":[17],"as":[18],"a":[19],"transducer":[20],"and":[21,47],"applying":[22],"MCSA":[23],"(Motor":[24],"Current":[25],"Signature":[26],"Analysis)":[27],"technique":[28],"to":[29],"identify":[30],"characteristic":[32],"fault":[33],"frequency":[34],"components.":[35],"Furthermore,":[36],"it":[37],"presents":[38],"detection":[40],"problems":[42,52],"transmission":[45],"system":[46],"its":[48],"relationship":[49],"with":[50],"originated":[53],"attached":[56],"load.":[57],"Data":[58],"extract":[59],"from":[60],"industrial":[61],"fans":[62],"effectiveness":[65],"methodology.":[68]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2014,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
