{"id":"https://openalex.org/W3082857216","doi":"https://doi.org/10.1109/icaci49185.2020.9177790","title":"Simulation of Load Control Scheme in Power Plant Based on Condensate Throttling Prediction Model","display_name":"Simulation of Load Control Scheme in Power Plant Based on Condensate Throttling Prediction Model","publication_year":2020,"publication_date":"2020-08-01","ids":{"openalex":"https://openalex.org/W3082857216","doi":"https://doi.org/10.1109/icaci49185.2020.9177790","mag":"3082857216"},"language":"en","primary_location":{"id":"doi:10.1109/icaci49185.2020.9177790","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icaci49185.2020.9177790","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 12th International Conference on Advanced Computational Intelligence (ICACI)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100357904","display_name":"Miaomiao Zhang","orcid":"https://orcid.org/0000-0002-4689-1991"},"institutions":[{"id":"https://openalex.org/I4210139507","display_name":"State Nuclear Power Technology Company (China)","ror":"https://ror.org/03pydjx38","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210139507"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Miaomiao Zhang","raw_affiliation_strings":["State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China","institution_ids":["https://openalex.org/I4210139507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017150556","display_name":"Ze Song","orcid":"https://orcid.org/0000-0001-7327-7180"},"institutions":[{"id":"https://openalex.org/I4210139507","display_name":"State Nuclear Power Technology Company (China)","ror":"https://ror.org/03pydjx38","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210139507"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ze Song","raw_affiliation_strings":["State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China","institution_ids":["https://openalex.org/I4210139507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100324517","display_name":"Xiaoyong Zhang","orcid":"https://orcid.org/0000-0002-1997-7247"},"institutions":[{"id":"https://openalex.org/I4210139507","display_name":"State Nuclear Power Technology Company (China)","ror":"https://ror.org/03pydjx38","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210139507"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaoyong Zhang","raw_affiliation_strings":["State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China","institution_ids":["https://openalex.org/I4210139507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052071429","display_name":"Liangyu Ma","orcid":"https://orcid.org/0000-0003-2951-6775"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liangyu Ma","raw_affiliation_strings":["Department of Automation, North China Electric Power University, Baoding, China"],"affiliations":[{"raw_affiliation_string":"Department of Automation, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000159619","display_name":"Wei Dan","orcid":"https://orcid.org/0000-0002-4527-5003"},"institutions":[{"id":"https://openalex.org/I4210139507","display_name":"State Nuclear Power Technology Company (China)","ror":"https://ror.org/03pydjx38","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210139507"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wei Dan","raw_affiliation_strings":["State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China"],"affiliations":[{"raw_affiliation_string":"State Nuclear Electric Power Planning, Design & Research Institute Co.,Ltd, Beijing, China","institution_ids":["https://openalex.org/I4210139507"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108152460","display_name":"Jingxuan Zhao","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jingxuan Zhao","raw_affiliation_strings":["Department of Automation, North China Electric Power University, Baoding, China"],"affiliations":[{"raw_affiliation_string":"Department of Automation, North China Electric Power University, Baoding, China","institution_ids":["https://openalex.org/I153473198"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5100357904"],"corresponding_institution_ids":["https://openalex.org/I4210139507"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.09912281,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"19","issue":null,"first_page":"150","last_page":"154"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.6970999836921692,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.6970999836921692,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/bandwidth-throttling","display_name":"Bandwidth throttling","score":0.9648594856262207},{"id":"https://openalex.org/keywords/unit-load","display_name":"Unit load","score":0.7086163759231567},{"id":"https://openalex.org/keywords/load-regulation","display_name":"Load regulation","score":0.529342770576477},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49081143736839294},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.48250889778137207},{"id":"https://openalex.org/keywords/peaking-power-plant","display_name":"Peaking power plant","score":0.4713194966316223},{"id":"https://openalex.org/keywords/power-station","display_name":"Power station","score":0.466453492641449},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.46557706594467163},{"id":"https://openalex.org/keywords/supercritical-fluid","display_name":"Supercritical fluid","score":0.4618339538574219},{"id":"https://openalex.org/keywords/control-logic","display_name":"Control logic","score":0.4569949507713318},{"id":"https://openalex.org/keywords/artificial-neural-network","display_name":"Artificial neural network","score":0.43220192193984985},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.41149604320526123},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.3892000615596771},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3603619933128357},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3456329107284546},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2855871319770813},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.26465967297554016},{"id":"https://openalex.org/keywords/gas-compressor","display_name":"Gas compressor","score":0.11812189221382141},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.08955618739128113},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.08256155252456665},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08203625679016113},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.08021596074104309}],"concepts":[{"id":"https://openalex.org/C173061102","wikidata":"https://www.wikidata.org/wiki/Q478819","display_name":"Bandwidth throttling","level":3,"score":0.9648594856262207},{"id":"https://openalex.org/C134750763","wikidata":"https://www.wikidata.org/wiki/Q625277","display_name":"Unit load","level":2,"score":0.7086163759231567},{"id":"https://openalex.org/C2776098794","wikidata":"https://www.wikidata.org/wiki/Q6663315","display_name":"Load regulation","level":3,"score":0.529342770576477},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49081143736839294},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.48250889778137207},{"id":"https://openalex.org/C154594046","wikidata":"https://www.wikidata.org/wiki/Q18979989","display_name":"Peaking power plant","level":4,"score":0.4713194966316223},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.466453492641449},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.46557706594467163},{"id":"https://openalex.org/C118419359","wikidata":"https://www.wikidata.org/wiki/Q682585","display_name":"Supercritical fluid","level":2,"score":0.4618339538574219},{"id":"https://openalex.org/C2776350369","wikidata":"https://www.wikidata.org/wiki/Q843479","display_name":"Control logic","level":2,"score":0.4569949507713318},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.43220192193984985},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.41149604320526123},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3892000615596771},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3603619933128357},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3456329107284546},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2855871319770813},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.26465967297554016},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.11812189221382141},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.08955618739128113},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.08256155252456665},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08203625679016113},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08021596074104309},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icaci49185.2020.9177790","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icaci49185.2020.9177790","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 12th International Conference on Advanced Computational Intelligence (ICACI)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6299999952316284,"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2380817135","https://openalex.org/W2383884247","https://openalex.org/W2384882777","https://openalex.org/W2889734676","https://openalex.org/W2971231993","https://openalex.org/W6903603037"],"related_works":["https://openalex.org/W2374659339","https://openalex.org/W2376895798","https://openalex.org/W3082857216","https://openalex.org/W2390309885","https://openalex.org/W4214837493","https://openalex.org/W2192376742","https://openalex.org/W2379022441","https://openalex.org/W4313854499","https://openalex.org/W2984685792","https://openalex.org/W4200400403"],"abstract_inverted_index":{"The":[0,89,101],"policy":[1],"of":[2,15,23,29,42,80],"deep":[3],"peak":[4],"shaving":[5],"puts":[6],"forward":[7],"higher":[8],"requirements":[9],"on":[10,47,58,69,95],"the":[11,24,40,70,76,81,85,96,105,111,120],"variable":[12],"load":[13,49,54,64,77,113],"capacity":[14],"thermal":[16],"power":[17],"units.":[18],"\"Condensate":[19],"throttling\"":[20],"is":[21,50,61,72,92,118,122],"one":[22],"methods":[25],"for":[26],"quick":[27],"response":[28,78,114],"unit":[30,35,48,82,98,112],"load.":[31],"Taking":[32],"600MW":[33],"supercritical":[34,97],"simulator":[36,99],"as":[37],"an":[38],"example,":[39],"influence":[41],"water":[43],"level":[44],"adjustment":[45],"valve":[46],"studied,":[51],"and":[52,124],"a":[53],"prediction":[55,65],"model":[56,71],"based":[57,68],"neural":[59],"network":[60],"established.":[62],"A":[63],"control":[66,106,116],"scheme":[67,107],"proposed":[73],"to":[74,126],"improve":[75,110],"speed":[79],"by":[83],"utilizing":[84],"condensate":[86],"throttling":[87],"characteristics.":[88],"simulation":[90],"test":[91],"carried":[93],"out":[94],"platform.":[100],"results":[102],"show":[103],"that":[104],"can":[108],"effectively":[109],"rate,":[115],"logic":[117],"clear,":[119],"method":[121],"simple":[123],"easy":[125],"be":[127],"applied":[128],"in":[129],"engineering.":[130]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}