{"id":"https://openalex.org/W4412129975","doi":"https://doi.org/10.1109/ias62731.2025.11061750","title":"Availability Analysis of Power Supply System in Data Center","display_name":"Availability Analysis of Power Supply System in Data Center","publication_year":2025,"publication_date":"2025-06-15","ids":{"openalex":"https://openalex.org/W4412129975","doi":"https://doi.org/10.1109/ias62731.2025.11061750"},"language":"en","primary_location":{"id":"doi:10.1109/ias62731.2025.11061750","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias62731.2025.11061750","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110183203","display_name":"Jian Hong Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I154864474","display_name":"National Taiwan University of Science and Technology","ror":"https://ror.org/00q09pe49","country_code":"TW","type":"education","lineage":["https://openalex.org/I154864474"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Jian Hong Liu","raw_affiliation_strings":["National Taiwan University of Science and Technology,Department of Electrical Engineering,Taipei,Taiwan,106335"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Taiwan University of Science and Technology,Department of Electrical Engineering,Taipei,Taiwan,106335","institution_ids":["https://openalex.org/I154864474"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5110183203"],"corresponding_institution_ids":["https://openalex.org/I154864474"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.16020355,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13924","display_name":"Internet of Things and Social Network Interactions","score":0.8234000205993652,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13924","display_name":"Internet of Things and Social Network Interactions","score":0.8234000205993652,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.7889999747276306,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14484","display_name":"Technology and Data Analysis","score":0.7832000255584717,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.5951697826385498},{"id":"https://openalex.org/keywords/center","display_name":"Center (category theory)","score":0.5697144865989685},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5059763789176941},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4854017198085785},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.11516007781028748},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.06346380710601807}],"concepts":[{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.5951697826385498},{"id":"https://openalex.org/C2779463800","wikidata":"https://www.wikidata.org/wiki/Q5062222","display_name":"Center (category theory)","level":2,"score":0.5697144865989685},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5059763789176941},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4854017198085785},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.11516007781028748},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.06346380710601807},{"id":"https://openalex.org/C8010536","wikidata":"https://www.wikidata.org/wiki/Q160398","display_name":"Crystallography","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias62731.2025.11061750","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias62731.2025.11061750","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8299999833106995,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320331164","display_name":"National Science and Technology Council","ror":"https://ror.org/00wnb9798"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2019673511","https://openalex.org/W2105574032","https://openalex.org/W2165587452"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W4391913857","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W2379482911","https://openalex.org/W2645858920"],"abstract_inverted_index":{"The":[0,133],"traditional":[1],"method":[2,44,75,99,135,154],"for":[3,84,171],"analyzing":[4],"the":[5,15,21,43,46,65,70,97,102,121,126,131],"power":[6,50,86,122],"supply":[7,51,87,123],"reliability":[8,68,88,165],"of":[9,24,48,69,109,125],"data":[10,71,91,111,127,151],"centers":[11],"is":[12,60,136,147],"based":[13,129],"on":[14,130],"Boolean":[16,35],"model.":[17],"This":[18,58,94],"approach":[19],"represents":[20],"operational":[22,67],"status":[23],"each":[25],"component":[26],"using":[27],"binary":[28],"values\u20140":[29],"and":[30,118,138,157,168,178],"1.":[31],"By":[32],"combining":[33],"these":[34],"values":[36],"to":[37,54,63,100],"reflect":[38],"various":[39],"equipment":[40,145,172],"operating":[41],"scenarios,":[42],"calculates":[45,120],"proportion":[47],"successful":[49],"paths":[52],"relative":[53],"all":[55],"possible":[56],"paths.":[57],"ratio":[59],"then":[61],"used":[62],"determine":[64],"overall":[66],"center.":[72],"However,":[73],"this":[74,153],"involves":[76],"high":[77],"analytical":[78,141],"complexity,":[79],"making":[80],"it":[81],"less":[82],"practical":[83],"calculating":[85],"in":[89,149],"real-world":[90],"center":[92,112,128],"applications.":[93],"paper":[95],"adopts":[96],"cascaded-circuit":[98],"analyze":[101],"equivalent":[103],"Mean":[104],"Time":[105],"Between":[106],"Failures":[107],"(MTBF)":[108],"a":[110,150],"including":[113],"Power":[114],"Supply":[115],"Units":[116],"(PSUs),":[117],"further":[119],"availability":[124,160],"MTBF.":[132],"proposed":[134],"simple":[137],"has":[139],"lower":[140],"complexity.":[142],"When":[143],"additional":[144],"expansion":[146],"required":[148],"center,":[152],"can":[155],"quickly":[156],"intuitively":[158],"provide":[159],"analysis":[161],"results.":[162],"It":[163],"offers":[164],"planners":[166],"immediate":[167],"efficient":[169],"strategies":[170],"reconfiguration,":[173],"thereby":[174],"supporting":[175],"more":[176],"effective":[177],"timely":[179],"infrastructure":[180],"expansion.":[181]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}