{"id":"https://openalex.org/W4411272148","doi":"https://doi.org/10.1109/ias55788.2024.11023832","title":"Transient Recovery Voltage Evaluation of Medium Voltage Generator Breaker Replacements","display_name":"Transient Recovery Voltage Evaluation of Medium Voltage Generator Breaker Replacements","publication_year":2024,"publication_date":"2024-10-20","ids":{"openalex":"https://openalex.org/W4411272148","doi":"https://doi.org/10.1109/ias55788.2024.11023832"},"language":"en","primary_location":{"id":"doi:10.1109/ias55788.2024.11023832","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias55788.2024.11023832","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5118197283","display_name":"Maxwell A Danku","orcid":null},"institutions":[{"id":"https://openalex.org/I4210138378","display_name":"Dominion (United States)","ror":"https://ror.org/038q98v71","country_code":"US","type":"company","lineage":["https://openalex.org/I4210138378"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Maxwell A Danku","raw_affiliation_strings":["Dominion Energy,Glen Allen,VA,USA,23060"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dominion Energy,Glen Allen,VA,USA,23060","institution_ids":["https://openalex.org/I4210138378"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083695627","display_name":"T. Abdelazim","orcid":"https://orcid.org/0000-0002-5671-186X"},"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Tamer Abdelazim Mellik","raw_affiliation_strings":["Eaton Corporation,Tukwila,WA,USA,98168"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Corporation,Tukwila,WA,USA,98168","institution_ids":["https://openalex.org/I4210091818"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083309044","display_name":"Thomas J. Dionise","orcid":"https://orcid.org/0000-0001-5786-8431"},"institutions":[{"id":"https://openalex.org/I4210091818","display_name":"Eaton (United States)","ror":"https://ror.org/00czndn44","country_code":"US","type":"company","lineage":["https://openalex.org/I4210091818","https://openalex.org/I4210139942"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Thomas J. Dionise","raw_affiliation_strings":["Eaton Corporation,Warrendale,PA,USA,15086"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Eaton Corporation,Warrendale,PA,USA,15086","institution_ids":["https://openalex.org/I4210091818"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.50048602,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.8788697719573975},{"id":"https://openalex.org/keywords/transient-recovery-voltage","display_name":"Transient recovery voltage","score":0.82417231798172},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.7167654633522034},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.6215261220932007},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6015121936798096},{"id":"https://openalex.org/keywords/transient-voltage-suppressor","display_name":"Transient voltage suppressor","score":0.5559895038604736},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5259820818901062},{"id":"https://openalex.org/keywords/transient-analysis","display_name":"Transient analysis","score":0.47635841369628906},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4268597960472107},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2773427963256836},{"id":"https://openalex.org/keywords/voltage-divider","display_name":"Voltage divider","score":0.24961477518081665},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.20186376571655273},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.20035317540168762},{"id":"https://openalex.org/keywords/transient-response","display_name":"Transient response","score":0.194298654794693},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.09650355577468872}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.8788697719573975},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.82417231798172},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.7167654633522034},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.6215261220932007},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6015121936798096},{"id":"https://openalex.org/C14915586","wikidata":"https://www.wikidata.org/wiki/Q1653998","display_name":"Transient voltage suppressor","level":3,"score":0.5559895038604736},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5259820818901062},{"id":"https://openalex.org/C2989121073","wikidata":"https://www.wikidata.org/wiki/Q1309019","display_name":"Transient analysis","level":3,"score":0.47635841369628906},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4268597960472107},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2773427963256836},{"id":"https://openalex.org/C49324399","wikidata":"https://www.wikidata.org/wiki/Q466758","display_name":"Voltage divider","level":3,"score":0.24961477518081665},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.20186376571655273},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.20035317540168762},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.194298654794693},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.09650355577468872},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias55788.2024.11023832","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias55788.2024.11023832","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7699999809265137,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2751680089","https://openalex.org/W2949468515","https://openalex.org/W4236976948","https://openalex.org/W4237336282","https://openalex.org/W4238952599","https://openalex.org/W4239650212","https://openalex.org/W4253473468","https://openalex.org/W4256468514","https://openalex.org/W4386372591","https://openalex.org/W4399940017"],"related_works":["https://openalex.org/W2170841002","https://openalex.org/W2266900650","https://openalex.org/W1967533142","https://openalex.org/W2034343262","https://openalex.org/W3029101738","https://openalex.org/W2169529353","https://openalex.org/W2368991229","https://openalex.org/W2810678620","https://openalex.org/W2042797273","https://openalex.org/W4249362708"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,45,48,56,71,78,80,89,98,103,116,119,137,144,163],"outcomes":[4],"of":[5,47,58,77,105],"a":[6,13,168,172],"comprehensive":[7],"technical":[8,52],"evaluation":[9,46],"conducted":[10],"to":[11,146],"assist":[12],"major":[14],"utility":[15,145],"retrofit":[16,147],"outmoded":[17,150],"medium":[18,28],"voltage":[19,29,93],"air":[20,153],"circuit":[21,32,61,154],"breakers":[22,33,40,62,107,155],"in":[23,63,167],"generator":[24,38,152],"switchgear":[25],"with":[26,156,162],"standard":[27],"vacuum":[30],"replacement":[31,39],"(MVVRs)":[34],"or":[35,131,159],"definite":[36],"purpose":[37],"(VRGs).":[41],"The":[42,140],"project":[43],"involved":[44],"necessary":[49],"and":[50,65,88,112,174],"sufficient":[51],"considerations":[53,69],"required":[54],"for":[55,108,136,171],"deployment":[57],"special":[59],"class":[60],"challenging":[64],"critical":[66],"installations.":[67],"These":[68],"are":[70],"maximum":[72],"symmetrical":[73],"rms":[74],"interrupting":[75],"duty":[76],"breaker,":[79],"temporary":[81],"overvoltage":[82],"(TOV)":[83],"imposed":[84],"on":[85],"associated":[86],"equipment,":[87],"resulting":[90],"transient":[91],"recovery":[92],"(TRV)":[94],"withstand":[95],"strength":[96],"across":[97],"breaker":[99,120],"contacts":[100],"that":[101],"follows":[102],"engagement":[104],"these":[106],"clearing":[109],"both":[110],"generator-fed":[111],"system-fed":[113],"faults.":[114],"Where":[115],"results":[117,142],"exceeded":[118],"ratings,":[121],"corrective":[122],"modification":[123],"steps":[124],"such":[125],"as":[126],"surge":[127,129],"arresters,":[128],"capacitors":[130],"snubber":[132],"circuits":[133],"were":[134],"recommended":[135],"utility's":[138],"consideration.":[139],"study":[141],"enabled":[143],"their":[148],"existing":[149],"MV":[151],"costeffective":[157],"MVVRs":[158],"VRGs":[160],"along":[161],"appropriate":[164],"mitigation":[165],"equipment":[166],"timely":[169],"manner":[170],"safe":[173],"continued":[175],"reliable":[176],"operation.":[177]},"counts_by_year":[],"updated_date":"2026-07-29T14:22:42.915294","created_date":"2025-10-10T00:00:00"}