{"id":"https://openalex.org/W4205499837","doi":"https://doi.org/10.1109/ias48185.2021.9677080","title":"A High Step Up SEPIC-Based Partial-Power Converter with wide input range","display_name":"A High Step Up SEPIC-Based Partial-Power Converter with wide input range","publication_year":2021,"publication_date":"2021-10-10","ids":{"openalex":"https://openalex.org/W4205499837","doi":"https://doi.org/10.1109/ias48185.2021.9677080"},"language":"en","primary_location":{"id":"doi:10.1109/ias48185.2021.9677080","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias48185.2021.9677080","pdf_url":null,"source":{"id":"https://openalex.org/S4363605335","display_name":"2021 IEEE Industry Applications Society Annual Meeting (IAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5058491902","display_name":"Rui Xu","orcid":"https://orcid.org/0000-0001-6658-5716"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Rui Xu","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042580412","display_name":"Shanshan Gao","orcid":"https://orcid.org/0009-0009-1314-2706"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shanshan Gao","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100429817","display_name":"Yijie Wang","orcid":"https://orcid.org/0000-0001-6959-8619"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yijie Wang","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5100341927","display_name":"Dianguo Xu","orcid":"https://orcid.org/0000-0002-1594-8625"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dianguo Xu","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5058491902"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.9013,"has_fulltext":false,"cited_by_count":10,"citation_normalized_percentile":{"value":0.95541015,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":91,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10363","display_name":"Low-power high-performance VLSI design","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flyback-converter","display_name":"Flyback converter","score":0.7634954452514648},{"id":"https://openalex.org/keywords/flyback-transformer","display_name":"Flyback transformer","score":0.7056634426116943},{"id":"https://openalex.org/keywords/buck\u2013boost-converter","display_name":"Buck\u2013boost converter","score":0.6896937489509583},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.54213947057724},{"id":"https://openalex.org/keywords/duty-cycle","display_name":"Duty cycle","score":0.5136274695396423},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.49103760719299316},{"id":"https://openalex.org/keywords/boost-converter","display_name":"Boost converter","score":0.47072187066078186},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4585352838039398},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44948866963386536},{"id":"https://openalex.org/keywords/forward-converter","display_name":"Forward converter","score":0.4119397699832916},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.40151891112327576},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.37035325169563293},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36591216921806335},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.3286767601966858},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2793598175048828},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.13574877381324768}],"concepts":[{"id":"https://openalex.org/C103303742","wikidata":"https://www.wikidata.org/wiki/Q1293595","display_name":"Flyback converter","level":4,"score":0.7634954452514648},{"id":"https://openalex.org/C17321440","wikidata":"https://www.wikidata.org/wiki/Q184909","display_name":"Flyback transformer","level":4,"score":0.7056634426116943},{"id":"https://openalex.org/C42043438","wikidata":"https://www.wikidata.org/wiki/Q1671740","display_name":"Buck\u2013boost converter","level":4,"score":0.6896937489509583},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.54213947057724},{"id":"https://openalex.org/C199822604","wikidata":"https://www.wikidata.org/wiki/Q557120","display_name":"Duty cycle","level":3,"score":0.5136274695396423},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.49103760719299316},{"id":"https://openalex.org/C78336795","wikidata":"https://www.wikidata.org/wiki/Q760134","display_name":"Boost converter","level":3,"score":0.47072187066078186},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4585352838039398},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44948866963386536},{"id":"https://openalex.org/C55118286","wikidata":"https://www.wikidata.org/wiki/Q634739","display_name":"Forward converter","level":4,"score":0.4119397699832916},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.40151891112327576},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.37035325169563293},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36591216921806335},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.3286767601966858},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2793598175048828},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13574877381324768},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias48185.2021.9677080","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias48185.2021.9677080","pdf_url":null,"source":{"id":"https://openalex.org/S4363605335","display_name":"2021 IEEE Industry Applications Society Annual Meeting (IAS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE Industry Applications Society Annual Meeting (IAS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1550755341","https://openalex.org/W2037827940","https://openalex.org/W2074419235","https://openalex.org/W2141087622","https://openalex.org/W2320972339","https://openalex.org/W2582120716","https://openalex.org/W2614206409","https://openalex.org/W2741343947","https://openalex.org/W2741846519","https://openalex.org/W2755574014","https://openalex.org/W2765332069","https://openalex.org/W2768540319","https://openalex.org/W2909431713","https://openalex.org/W2991155167"],"related_works":["https://openalex.org/W2061154986","https://openalex.org/W4323891767","https://openalex.org/W2588047361","https://openalex.org/W2392412651","https://openalex.org/W2393008774","https://openalex.org/W1497563151","https://openalex.org/W2389366188","https://openalex.org/W2274754534","https://openalex.org/W1914259762","https://openalex.org/W1535567086"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,42,76,95],"high":[4,33,38],"step":[5],"up":[6],"SEPIC-based":[7],"partial-power":[8,11,56,91],"converter.":[9],"The":[10],"Flyback":[12,57,92],"circuit":[13,18],"and":[14,70,110,120],"the":[15,24,51,55,63,66,71,86,90,98,103,106,117],"modified":[16],"SEPIC":[17],"are":[19,124],"connected":[20],"in":[21,75,126],"cascade":[22],"therefore":[23],"voltage":[25,34,64],"gain":[26,35],"of":[27,97],"each":[28],"cell":[29],"is":[30,54,59,132],"multiplied,":[31],"obtaining":[32],"without":[36],"extremely":[37],"duty":[39],"cycle":[40],"over":[41],"wide":[43,67],"input":[44,68],"range.":[45],"As":[46],"for":[47,61],"this":[48,115],"two-stage":[49],"converter,":[50,89],"first":[52],"stage":[53,73],"which":[58],"responsible":[60],"regulating":[62],"within":[65],"range":[69],"second":[72],"operates":[74],"fixed":[77],"state":[78],"while":[79],"providing":[80],"zero-voltage":[81],"soft":[82],"switching.":[83],"Compared":[84],"with":[85],"full":[87],"power":[88,99,112],"converter":[93],"processes":[94],"fraction":[96],"that":[100],"flows":[101],"from":[102],"source":[104],"to":[105,134],"load,":[107],"reducing":[108],"losses":[109],"increasing":[111],"density.":[113],"In":[114],"paper,":[116],"operational":[118],"principle":[119],"parameter":[121],"design":[122],"process":[123],"introduced":[125],"detail.":[127],"A":[128],"100":[129],"W":[130],"prototype":[131],"designed":[133],"demonstrate":[135],"theoretical":[136],"analysis.":[137]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3}],"updated_date":"2026-04-05T06:14:27.290980","created_date":"2025-10-10T00:00:00"}
