{"id":"https://openalex.org/W3126302358","doi":"https://doi.org/10.1109/ias44978.2020.9334859","title":"Comparison of Communication-based and Coordinated-based Frequency Control Schemes for HVDC-Connected Offshore Wind Farms","display_name":"Comparison of Communication-based and Coordinated-based Frequency Control Schemes for HVDC-Connected Offshore Wind Farms","publication_year":2020,"publication_date":"2020-10-10","ids":{"openalex":"https://openalex.org/W3126302358","doi":"https://doi.org/10.1109/ias44978.2020.9334859","mag":"3126302358"},"language":"en","primary_location":{"id":"doi:10.1109/ias44978.2020.9334859","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias44978.2020.9334859","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051019311","display_name":"Yuan\u2010Kang Wu","orcid":"https://orcid.org/0000-0002-3707-4770"},"institutions":[{"id":"https://openalex.org/I148099254","display_name":"National Chung Cheng University","ror":"https://ror.org/0028v3876","country_code":"TW","type":"education","lineage":["https://openalex.org/I148099254"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Yuan-Kang Wu","raw_affiliation_strings":["National Chung-Cheng University, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Chung-Cheng University, Taiwan","institution_ids":["https://openalex.org/I148099254"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030998048","display_name":"Guan-Liang Lu","orcid":"https://orcid.org/0000-0003-0676-5402"},"institutions":[{"id":"https://openalex.org/I148099254","display_name":"National Chung Cheng University","ror":"https://ror.org/0028v3876","country_code":"TW","type":"education","lineage":["https://openalex.org/I148099254"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Guan-Liang Lu","raw_affiliation_strings":["National Chung-Cheng University, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Chung-Cheng University, Taiwan","institution_ids":["https://openalex.org/I148099254"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044818893","display_name":"Chung-Han Lin","orcid":"https://orcid.org/0000-0001-8841-7721"},"institutions":[{"id":"https://openalex.org/I148099254","display_name":"National Chung Cheng University","ror":"https://ror.org/0028v3876","country_code":"TW","type":"education","lineage":["https://openalex.org/I148099254"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chung-Han Lin","raw_affiliation_strings":["National Chung-Cheng University, Taiwan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Chung-Cheng University, Taiwan","institution_ids":["https://openalex.org/I148099254"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I148099254"],"apc_list":null,"apc_paid":null,"fwci":0.1009,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.45304494,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":93},"biblio":{"volume":"pp","issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/offshore-wind-power","display_name":"Offshore wind power","score":0.7127023935317993},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.5425077676773071},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.5260236859321594},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5240219235420227},{"id":"https://openalex.org/keywords/high-voltage-direct-current","display_name":"High-voltage direct current","score":0.5092610120773315},{"id":"https://openalex.org/keywords/transmission-system","display_name":"Transmission system","score":0.4279051423072815},{"id":"https://openalex.org/keywords/frequency-grid","display_name":"Frequency grid","score":0.4277694821357727},{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.41509681940078735},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.34816277027130127},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.34331703186035156},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.34200817346572876},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.32037243247032166},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.28501930832862854},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.13971620798110962}],"concepts":[{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.7127023935317993},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.5425077676773071},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5260236859321594},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5240219235420227},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.5092610120773315},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.4279051423072815},{"id":"https://openalex.org/C21905445","wikidata":"https://www.wikidata.org/wiki/Q5502873","display_name":"Frequency grid","level":3,"score":0.4277694821357727},{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.41509681940078735},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.34816277027130127},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.34331703186035156},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.34200817346572876},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.32037243247032166},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.28501930832862854},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.13971620798110962}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias44978.2020.9334859","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias44978.2020.9334859","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2020 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8999999761581421}],"awards":[],"funders":[{"id":"https://openalex.org/F4320309618","display_name":"Ministry of Science and Technology","ror":"https://ror.org/02b207r52"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W326894746","https://openalex.org/W1896220994","https://openalex.org/W1979279116","https://openalex.org/W2000685472","https://openalex.org/W2022285837","https://openalex.org/W2026991617","https://openalex.org/W2028341701","https://openalex.org/W2031196831","https://openalex.org/W2063868897","https://openalex.org/W2094995413","https://openalex.org/W2103687379","https://openalex.org/W2113893314","https://openalex.org/W2146531819","https://openalex.org/W2151389342","https://openalex.org/W2219674758","https://openalex.org/W2242410837","https://openalex.org/W2258862386","https://openalex.org/W2342846244","https://openalex.org/W2553566779","https://openalex.org/W2558595233","https://openalex.org/W2587057072","https://openalex.org/W2731058406","https://openalex.org/W2755887995","https://openalex.org/W2759186181","https://openalex.org/W2773327441","https://openalex.org/W2790750764","https://openalex.org/W2885938875","https://openalex.org/W2888741559","https://openalex.org/W2906091134","https://openalex.org/W2975319381","https://openalex.org/W6666402480","https://openalex.org/W6744228699"],"related_works":["https://openalex.org/W2529755282","https://openalex.org/W4213134919","https://openalex.org/W2766311747","https://openalex.org/W3023710910","https://openalex.org/W2751689184","https://openalex.org/W2283881681","https://openalex.org/W4321844062","https://openalex.org/W4360996252","https://openalex.org/W4379525856","https://openalex.org/W4231913803"],"abstract_inverted_index":{"As":[0],"the":[1,7,20,86,92,103,107,118,133,137,150,156,166,182,185,190,198],"penetration":[2],"of":[3,120,136,170,184],"wind":[4,11,24,40,77,95,126,171,195],"generation":[5],"increases,":[6],"frequency":[8,43,61,122,161],"support":[9,62],"from":[10],"turbines":[12,172],"is":[13,173],"necessary.":[14],"There":[15],"are":[16,99],"many":[17],"advantages":[18],"for":[19,60,73,91,197],"connection":[21],"between":[22],"offshore":[23,76,94,125],"farms":[25,41,196],"and":[26,45,106,147,178],"electricity":[27],"grid":[28,121],"via":[29,142],"a":[30,74,82],"high-voltage":[31],"direct":[32],"current":[33],"(HVDC)":[34],"system.":[35],"HVDC":[36,141,186],"transmission":[37,55],"systems":[38],"help":[39,194],"provide":[42],"regulation":[44],"voltage":[46,139,151],"control,":[47],"which":[48,175],"have":[49,63],"more":[50],"flexibility":[51],"compared":[52,69],"to":[53,116,123,159,193],"HVAC":[54],"systems.":[56],"Several":[57],"control":[58,71,89,145,169],"methods":[59,72,90,131],"been":[64],"developed.":[65],"However,":[66],"few":[67],"works":[68],"various":[70],"HVDC-connected":[75,93],"farm.":[78,96],"This":[79],"work":[80],"proposes":[81],"detailed":[83],"comparison":[84],"on":[85,102,140],"main":[87],"frequency-support":[88],"These":[97],"controls":[98],"mainly":[100],"based":[101],"communication-based":[104,111],"schemes":[105],"coordinated-based":[108,130],"methods.":[109],"The":[110,129],"scheme":[112],"uses":[113],"communication":[114],"devices":[115],"transfer":[117,132],"information":[119,135],"an":[124],"farm":[127],"directly.":[128],"dynamic":[134],"DC":[138],"generator":[143],"emulation":[144],"(GEC),":[146],"then":[148],"enable":[149],"source":[152],"converter":[153],"(VSC)":[154],"at":[155],"wind-farm":[157],"side":[158],"supply":[160],"regulation.":[162],"In":[163],"this":[164],"work,":[165],"synthetic":[167],"inertial":[168],"considered,":[174],"include":[176],"inertia":[177],"droop":[179],"controllers;":[180],"furthermore,":[181],"capacitors":[183],"system":[187],"can":[188],"release":[189],"stored":[191],"energy":[192],"frequency-regulation":[199],"function.":[200]},"counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}