{"id":"https://openalex.org/W2767867947","doi":"https://doi.org/10.1109/ias.2017.8101761","title":"Multi-stage optimal PMU placement including substation infrastructure","display_name":"Multi-stage optimal PMU placement including substation infrastructure","publication_year":2017,"publication_date":"2017-10-01","ids":{"openalex":"https://openalex.org/W2767867947","doi":"https://doi.org/10.1109/ias.2017.8101761","mag":"2767867947"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2017.8101761","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2017.8101761","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5084158339","display_name":"Saleh Almasabi","orcid":"https://orcid.org/0000-0003-4653-190X"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Saleh Almasabi","raw_affiliation_strings":["Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA","institution_ids":["https://openalex.org/I87216513"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5035972401","display_name":"Joydeep Mitra","orcid":"https://orcid.org/0000-0001-9287-0983"},"institutions":[{"id":"https://openalex.org/I87216513","display_name":"Michigan State University","ror":"https://ror.org/05hs6h993","country_code":"US","type":"education","lineage":["https://openalex.org/I87216513"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Joydeep Mitra","raw_affiliation_strings":["Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan, USA","institution_ids":["https://openalex.org/I87216513"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0233,"has_fulltext":false,"cited_by_count":12,"citation_normalized_percentile":{"value":0.78976161,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5802094340324402},{"id":"https://openalex.org/keywords/stage","display_name":"Stage (stratigraphy)","score":0.5515227913856506},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3672492504119873},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19647863507270813},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.13470587134361267}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5802094340324402},{"id":"https://openalex.org/C146357865","wikidata":"https://www.wikidata.org/wiki/Q1123245","display_name":"Stage (stratigraphy)","level":2,"score":0.5515227913856506},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3672492504119873},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19647863507270813},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.13470587134361267},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias.2017.8101761","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2017.8101761","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.6499999761581421}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W1511875879","https://openalex.org/W1966089070","https://openalex.org/W1978234070","https://openalex.org/W1994306174","https://openalex.org/W2000293894","https://openalex.org/W2005852562","https://openalex.org/W2008048828","https://openalex.org/W2017361404","https://openalex.org/W2018897349","https://openalex.org/W2029219149","https://openalex.org/W2030230833","https://openalex.org/W2032518261","https://openalex.org/W2032960059","https://openalex.org/W2041851681","https://openalex.org/W2064899320","https://openalex.org/W2073082177","https://openalex.org/W2078198692","https://openalex.org/W2110448242","https://openalex.org/W2116100905","https://openalex.org/W2123682012","https://openalex.org/W2128812635","https://openalex.org/W2133238120","https://openalex.org/W2145862876","https://openalex.org/W2151637991","https://openalex.org/W2165886836","https://openalex.org/W2316205619","https://openalex.org/W2317330621","https://openalex.org/W2330579332","https://openalex.org/W2356878782","https://openalex.org/W2371084438","https://openalex.org/W2388024387","https://openalex.org/W2557077215","https://openalex.org/W2587433340","https://openalex.org/W2598540099","https://openalex.org/W4246219036","https://openalex.org/W6679388329"],"related_works":["https://openalex.org/W2748952813","https://openalex.org/W2390279801","https://openalex.org/W2358668433","https://openalex.org/W2376932109","https://openalex.org/W2001405890","https://openalex.org/W2382290278","https://openalex.org/W2478288626","https://openalex.org/W4391913857","https://openalex.org/W2350741829","https://openalex.org/W2530322880"],"abstract_inverted_index":{"Phaser":[0],"measurement":[1,30],"units":[2],"(PMUs)":[3],"significantly":[4],"benefit":[5],"the":[6,39,47,59,64,80,92,100,106,111,117,129,133,150,154,158,169,183,191],"operation":[7],"and":[8,37,63,132,156,196],"control":[9,40],"of":[10,44,61,70,76,82,95,103,113,136,160],"power":[11],"systems.":[12,200],"They":[13],"offer":[14],"precise":[15],"phaser":[16],"measurements":[17,24],"with":[18],"a":[19],"high":[20],"refresh":[21],"rate.":[22],"These":[23],"are":[25],"utilized":[26],"for":[27],"wide":[28],"area":[29],"system":[31],"(WAMS)":[32],"to":[33,52,58,90,181],"improve":[34],"situational":[35],"awareness":[36],"enhance":[38],"infrastructure.":[41,66,119],"In":[42],"spite":[43],"these":[45,96],"advantages,":[46],"industry":[48],"has":[49],"been":[50,87],"slow":[51],"adopt":[53],"PMU":[54,71],"technology,":[55],"largely":[56],"due":[57],"cost":[60,108,112,135,151],"PMUs":[62,77,104,114],"communication":[65,118,130],"However,":[67],"judicious":[68],"selection":[69],"locations,":[72],"through":[73],"optimal":[74],"placement":[75],"(OPP)":[78],"enables":[79],"minimization":[81],"installation":[83,134,143],"cost.":[84],"There":[85],"have":[86],"several":[88],"approaches":[89,97],"solve":[91,182],"OPP;":[93],"most":[94],"assume":[98],"that":[99,126],"minimum":[101,107],"number":[102,159],"achieves":[105],"or":[109],"consider":[110],"without":[115],"considering":[116],"This":[120],"paper":[121],"presents":[122],"an":[123],"OPP":[124],"approach":[125,140,187],"considers":[127],"both":[128],"infrastructure":[131],"PMUs.":[137,161],"The":[138,185],"proposed":[139,170,186],"uses":[141],"multi-stage":[142],"where":[144],"each":[145],"stage":[146],"is":[147,179,188],"dependent":[148],"on":[149,190],"set":[152],"by":[153],"utility":[155],"not":[157],"Higher":[162],"priority":[163],"buses":[164],"can":[165],"be":[166],"chosen":[167],"under":[168],"approach.":[171],"An":[172],"opposition-based":[173],"elitist":[174],"binary":[175],"genetic":[176],"algorithm":[177],"(O-BEBGA)":[178],"used":[180],"OPP.":[184],"tested":[189],"IEEE":[192,194,197],"14-bus,":[193],"RTS":[195],"30-bus":[198],"test":[199]},"counts_by_year":[{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":6}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
