{"id":"https://openalex.org/W2036994953","doi":"https://doi.org/10.1109/ias.2012.6374112","title":"Nonlinear fuzzy model for operating condition evaluation of power cables in tunnels","display_name":"Nonlinear fuzzy model for operating condition evaluation of power cables in tunnels","publication_year":2012,"publication_date":"2012-10-01","ids":{"openalex":"https://openalex.org/W2036994953","doi":"https://doi.org/10.1109/ias.2012.6374112","mag":"2036994953"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2012.6374112","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2012.6374112","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110651818","display_name":"Huibin Sui","orcid":null},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Hui-bin Sui","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China","School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]},{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100633721","display_name":"Ke\u2010Jun Li","orcid":"https://orcid.org/0000-0002-7255-9044"},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ke-jun Li","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China","School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]},{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082096514","display_name":"Ying Sun","orcid":"https://orcid.org/0000-0001-7316-2236"},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ying Sun","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China","School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]},{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, 17923 Jingshi Road, Jinan, 250061, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100940320","display_name":"Meng Liu","orcid":"https://orcid.org/0000-0003-2175-4402"},"institutions":[{"id":"https://openalex.org/I189196454","display_name":"The University of Texas at Arlington","ror":"https://ror.org/019kgqr73","country_code":"US","type":"education","lineage":["https://openalex.org/I189196454"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Meng Liu","raw_affiliation_strings":["Energy System Research Center, University of Texas, Arlington, TX, USA","Energy System Research Center, University of Texas at Arlington, TX 76019, USA"],"affiliations":[{"raw_affiliation_string":"Energy System Research Center, University of Texas, Arlington, TX, USA","institution_ids":["https://openalex.org/I189196454"]},{"raw_affiliation_string":"Energy System Research Center, University of Texas at Arlington, TX 76019, USA","institution_ids":["https://openalex.org/I189196454"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5110651818"],"corresponding_institution_ids":["https://openalex.org/I154099455"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.10063671,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"16","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10761","display_name":"Vehicular Ad Hoc Networks (VANETs)","score":0.9656999707221985,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10761","display_name":"Vehicular Ad Hoc Networks (VANETs)","score":0.9656999707221985,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14011","display_name":"Elevator Systems and Control","score":0.9578999876976013,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9546999931335449,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7135754823684692},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.658867359161377},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.591046154499054},{"id":"https://openalex.org/keywords/analytic-hierarchy-process","display_name":"Analytic hierarchy process","score":0.5273167490959167},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.47754204273223877},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4746972918510437},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.468919575214386},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.44905614852905273},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.4325104355812073},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4210716784000397},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.41773372888565063},{"id":"https://openalex.org/keywords/operations-research","display_name":"Operations research","score":0.15298119187355042}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7135754823684692},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.658867359161377},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.591046154499054},{"id":"https://openalex.org/C87345402","wikidata":"https://www.wikidata.org/wiki/Q485202","display_name":"Analytic hierarchy process","level":2,"score":0.5273167490959167},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.47754204273223877},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4746972918510437},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.468919575214386},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44905614852905273},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4325104355812073},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4210716784000397},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.41773372888565063},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.15298119187355042},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias.2012.6374112","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2012.6374112","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W2073651359","https://openalex.org/W2114007705","https://openalex.org/W2119401602","https://openalex.org/W2128593828","https://openalex.org/W2352228553","https://openalex.org/W2352771345","https://openalex.org/W2360409834","https://openalex.org/W2365137510","https://openalex.org/W2368196589","https://openalex.org/W2377338968","https://openalex.org/W2378780419","https://openalex.org/W2393799818","https://openalex.org/W7072036211"],"related_works":["https://openalex.org/W2033512842","https://openalex.org/W4322734194","https://openalex.org/W4233600955","https://openalex.org/W2913665393","https://openalex.org/W2369695847","https://openalex.org/W3005535424","https://openalex.org/W2994319598","https://openalex.org/W2047067935","https://openalex.org/W1607054433","https://openalex.org/W2110842462"],"abstract_inverted_index":{"To":[0],"assure":[1],"the":[2,8,16,21,40,45,54,86,99,103,107,112,117,122,129,140,144],"construction":[3],"and":[4,92,106,114,150],"operation":[5,18,64],"security":[6],"of":[7,20,44,121],"smart":[9],"grid,":[10],"it":[11],"is":[12,84,90,148],"necessary":[13],"to":[14,97],"assess":[15],"real-time":[17],"reliability":[19],"power":[22,27,46,138],"cables":[23,123],"which":[24,38],"work":[25],"in":[26,137],"tunnels":[28],"by":[29],"using":[30],"on-line":[31],"monitoring":[32],"data.":[33],"An":[34],"online":[35],"assessment":[36,79,83,146],"system,":[37],"presents":[39],"important":[41],"operating":[42,119],"characteristics":[43],"cables,":[47],"has":[48],"been":[49],"built":[50],"up":[51],"based":[52],"on":[53,128],"following":[55],"data:":[56],"some":[57],"preventive":[58],"experiments":[59],"results":[60],"data,":[61],"working":[62],"environment,":[63],"records,":[65,67],"maintenance":[66],"etc.":[68],"With":[69],"analytic":[70],"hierarchy":[71],"process":[72],"method,":[73],"an":[74],"improved":[75],"fuzzy":[76],"integrated":[77],"evaluation":[78],"model":[80,147],"for":[81,102,133],"cable":[82,136],"proposed,":[85],"relative":[87],"interiority":[88],"indicator":[89],"adopted,":[91],"different":[93],"methods":[94],"are":[95],"used":[96],"determine":[98],"membership":[100],"functions":[101],"qualitative":[104],"indices":[105],"quantitative":[108],"indices.":[109],"Through":[110],"assessing":[111],"layer":[113],"sub-layer":[115],"factors,":[116],"comprehensive":[118],"conditions":[120],"can":[124],"be":[125],"estimated.":[126],"Based":[127],"actual":[130],"monitor":[131],"data":[132],"a":[134],"220kV":[135],"tunnel,":[139],"analysis":[141],"result":[142],"shows":[143],"proposed":[145],"correct":[149],"effective.":[151]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
