{"id":"https://openalex.org/W2050813062","doi":"https://doi.org/10.1109/ias.2011.6074392","title":"Determining proximity warning and action zones for a magnetic proximity detection system","display_name":"Determining proximity warning and action zones for a magnetic proximity detection system","publication_year":2011,"publication_date":"2011-10-01","ids":{"openalex":"https://openalex.org/W2050813062","doi":"https://doi.org/10.1109/ias.2011.6074392","mag":"2050813062"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2011.6074392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2011.6074392","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://zenodo.org/record/1269446","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070307293","display_name":"Christopher C. Jobes","orcid":"https://orcid.org/0000-0002-9667-8048"},"institutions":[{"id":"https://openalex.org/I198423848","display_name":"National Institute for Occupational Safety and Health","ror":"https://ror.org/0502a2655","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289490764","https://openalex.org/I1299022934","https://openalex.org/I198423848"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Christopher Jobes","raw_affiliation_strings":["National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA"],"affiliations":[{"raw_affiliation_string":"National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I198423848"]},{"raw_affiliation_string":"The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA","institution_ids":["https://openalex.org/I198423848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111754734","display_name":"Jacob Carr","orcid":null},"institutions":[{"id":"https://openalex.org/I198423848","display_name":"National Institute for Occupational Safety and Health","ror":"https://ror.org/0502a2655","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289490764","https://openalex.org/I1299022934","https://openalex.org/I198423848"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jacob Carr","raw_affiliation_strings":["National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA"],"affiliations":[{"raw_affiliation_string":"National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I198423848"]},{"raw_affiliation_string":"The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA","institution_ids":["https://openalex.org/I198423848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023914890","display_name":"Joseph P. DuCarme","orcid":null},"institutions":[{"id":"https://openalex.org/I198423848","display_name":"National Institute for Occupational Safety and Health","ror":"https://ror.org/0502a2655","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289490764","https://openalex.org/I1299022934","https://openalex.org/I198423848"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Joseph DuCarme","raw_affiliation_strings":["National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA"],"affiliations":[{"raw_affiliation_string":"National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I198423848"]},{"raw_affiliation_string":"The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA","institution_ids":["https://openalex.org/I198423848"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5002627995","display_name":"Justin Patts","orcid":"https://orcid.org/0000-0001-8036-5912"},"institutions":[{"id":"https://openalex.org/I198423848","display_name":"National Institute for Occupational Safety and Health","ror":"https://ror.org/0502a2655","country_code":"US","type":"facility","lineage":["https://openalex.org/I1289490764","https://openalex.org/I1299022934","https://openalex.org/I198423848"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Justin Patts","raw_affiliation_strings":["National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA"],"affiliations":[{"raw_affiliation_string":"National Institute of Occupational Safety and Health, Pittsburgh, PA, USA","institution_ids":["https://openalex.org/I198423848"]},{"raw_affiliation_string":"The National Institute for Occupational, Safety and Health, Pittsburgh, PA 15236, USA","institution_ids":["https://openalex.org/I198423848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5070307293"],"corresponding_institution_ids":["https://openalex.org/I198423848"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.10766698,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9300000071525574,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9300000071525574,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9291999936103821,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9081000089645386,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/alarm","display_name":"ALARM","score":0.5833137035369873},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.560971736907959},{"id":"https://openalex.org/keywords/action","display_name":"Action (physics)","score":0.5528725981712341},{"id":"https://openalex.org/keywords/proximity-sensor","display_name":"Proximity sensor","score":0.5045300722122192},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.4814014434814453},{"id":"https://openalex.org/keywords/warning-system","display_name":"Warning system","score":0.475222647190094},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.46292921900749207},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.41053611040115356},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2874600887298584},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.13942328095436096},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11808332800865173}],"concepts":[{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.5833137035369873},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.560971736907959},{"id":"https://openalex.org/C2780791683","wikidata":"https://www.wikidata.org/wiki/Q846785","display_name":"Action (physics)","level":2,"score":0.5528725981712341},{"id":"https://openalex.org/C135403697","wikidata":"https://www.wikidata.org/wiki/Q796765","display_name":"Proximity sensor","level":2,"score":0.5045300722122192},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.4814014434814453},{"id":"https://openalex.org/C29825287","wikidata":"https://www.wikidata.org/wiki/Q1427940","display_name":"Warning system","level":2,"score":0.475222647190094},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.46292921900749207},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.41053611040115356},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2874600887298584},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13942328095436096},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11808332800865173},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/ias.2011.6074392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2011.6074392","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2011 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},{"id":"pmh:oai:zenodo.org:1269446","is_oa":true,"landing_page_url":"https://zenodo.org/record/1269446","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"}],"best_oa_location":{"id":"pmh:oai:zenodo.org:1269446","is_oa":true,"landing_page_url":"https://zenodo.org/record/1269446","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferencePaper"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W104418415","https://openalex.org/W279726113","https://openalex.org/W1491797991","https://openalex.org/W1995598724","https://openalex.org/W2044223409","https://openalex.org/W2054369158","https://openalex.org/W2126154431","https://openalex.org/W2161657262","https://openalex.org/W6610116903","https://openalex.org/W6629350661","https://openalex.org/W6663992471","https://openalex.org/W6678681730","https://openalex.org/W6683734222"],"related_works":["https://openalex.org/W1584123598","https://openalex.org/W2731305060","https://openalex.org/W2732807254","https://openalex.org/W2372003537","https://openalex.org/W2587670262","https://openalex.org/W3091941553","https://openalex.org/W3037375888","https://openalex.org/W2366730739","https://openalex.org/W3037303542","https://openalex.org/W2365317830"],"abstract_inverted_index":{"Researchers":[0],"at":[1],"the":[2,34,38,41,61,71,116,150],"National":[3],"Institute":[4],"for":[5,15,144],"Occupational":[6],"Safety":[7],"and":[8,76,123,138,147],"Health":[9],"(NIOSH)":[10],"are":[11,127],"developing":[12],"intelligent":[13,117],"software":[14],"use":[16,114],"with":[17],"electromagnetic":[18],"proximity":[19,105,118,136,155],"detection":[20,119,156],"systems.":[21],"The":[22,83],"technology":[23,84],"accurately":[24],"locates":[25],"workers":[26,39],"around":[27,40],"mining":[28,91],"machines":[29,92,108],"in":[30,98,103,109],"real":[31],"time.":[32],"With":[33,113],"accurate":[35],"locations":[36],"of":[37,115,152],"equipment":[42],"being":[43],"known,":[44],"their":[45],"safety":[46,96],"status":[47],"can":[48,63],"be":[49,64,131],"evaluated.":[50],"If":[51],"a":[52,59,153],"worker":[53,72],"is":[54,85,142],"located":[55],"dangerously":[56],"close":[57,104],"to":[58,69,80,88,106,125,130],"machine,":[60],"machine":[62],"partially":[65],"or":[66],"completely":[67],"disabled":[68],"protect":[70],"from":[73],"striking,":[74],"pinning":[75],"entanglement":[77],"hazards":[78],"according":[79],"pre-defined":[81],"logic.":[82],"particularly":[86],"applicable":[87],"mobile":[89],"underground":[90,159],"which":[93],"offer":[94],"difficult":[95],"challenges":[97],"that":[99],"operators":[100],"generally":[101],"work":[102],"these":[107],"very":[110],"restricted":[111],"spaces.":[112],"system,":[120],"nuisance":[121],"alarms":[122],"failures":[124],"alarm":[126],"also":[128],"expected":[129],"sharply":[132],"reduced.":[133],"An":[134],"effective":[135],"warning":[137],"action":[139],"zone":[140],"scheme":[141],"necessary":[143],"safe":[145],"implementation":[146],"will":[148],"improve":[149],"acceptance":[151],"magnetic":[154],"system":[157],"by":[158],"workers.":[160]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":2},{"year":2016,"cited_by_count":1}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}
