{"id":"https://openalex.org/W1967034317","doi":"https://doi.org/10.1109/ias.2010.5616822","title":"Rule Based Fault Tolerant Protection System Using IEC 61850 Protocol","display_name":"Rule Based Fault Tolerant Protection System Using IEC 61850 Protocol","publication_year":2010,"publication_date":"2010-10-01","ids":{"openalex":"https://openalex.org/W1967034317","doi":"https://doi.org/10.1109/ias.2010.5616822","mag":"1967034317"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2010.5616822","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5616822","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5019042574","display_name":"W.L. Chan","orcid":"https://orcid.org/0000-0002-4637-0344"},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"W. L. Chan","raw_affiliation_strings":["Hongkong Polytech. Univ., Kowloon, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hongkong Polytech. Univ., Kowloon, China","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102954288","display_name":"Sheng Su","orcid":"https://orcid.org/0000-0003-3201-0193"},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Sheng Su","raw_affiliation_strings":["Hong Kong Polytechnic University, Hong Kong, China","Hongkong Polytechnic University, Kowloon, Hunghom, HongKong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]},{"raw_affiliation_string":"Hongkong Polytechnic University, Kowloon, Hunghom, HongKong","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035317975","display_name":"Dongyuan Shi","orcid":"https://orcid.org/0000-0002-8832-6595"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dongyuan Shi","raw_affiliation_strings":["Huazhong Univ. of Sci. & Technol., Wuhan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huazhong Univ. of Sci. & Technol., Wuhan, China","institution_ids":["https://openalex.org/I47720641"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5011095703","display_name":"Xianzhong Duan","orcid":"https://orcid.org/0000-0002-9492-1243"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xianzhong Duan","raw_affiliation_strings":["Huazhong Univ. of Sci. & Technol., Wuhan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huazhong Univ. of Sci. & Technol., Wuhan, China","institution_ids":["https://openalex.org/I47720641"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.05116268,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"27","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9944999814033508,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9897000193595886,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.9808961153030396},{"id":"https://openalex.org/keywords/protocol","display_name":"Protocol (science)","score":0.6399163007736206},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.6235976219177246},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5747250914573669},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5463926196098328},{"id":"https://openalex.org/keywords/fault-tolerance","display_name":"Fault tolerance","score":0.518272340297699},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5123825669288635},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.444345086812973},{"id":"https://openalex.org/keywords/process-automation-system","display_name":"Process automation system","score":0.42974674701690674},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.42414921522140503},{"id":"https://openalex.org/keywords/function","display_name":"Function (biology)","score":0.4138650596141815},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33737558126449585},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.32231763005256653},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.24612754583358765}],"concepts":[{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.9808961153030396},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.6399163007736206},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.6235976219177246},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5747250914573669},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5463926196098328},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.518272340297699},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5123825669288635},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.444345086812973},{"id":"https://openalex.org/C21457203","wikidata":"https://www.wikidata.org/wiki/Q4056293","display_name":"Process automation system","level":3,"score":0.42974674701690674},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.42414921522140503},{"id":"https://openalex.org/C14036430","wikidata":"https://www.wikidata.org/wiki/Q3736076","display_name":"Function (biology)","level":2,"score":0.4138650596141815},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33737558126449585},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.32231763005256653},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.24612754583358765},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C78458016","wikidata":"https://www.wikidata.org/wiki/Q840400","display_name":"Evolutionary biology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C204787440","wikidata":"https://www.wikidata.org/wiki/Q188504","display_name":"Alternative medicine","level":2,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias.2010.5616822","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5616822","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","display_name":"Peace, Justice and strong institutions","score":0.6600000262260437}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1978285438","https://openalex.org/W1983643289","https://openalex.org/W2020876750","https://openalex.org/W2037580229","https://openalex.org/W2106736880","https://openalex.org/W2107247353","https://openalex.org/W2114758896","https://openalex.org/W2136471120","https://openalex.org/W2143148279","https://openalex.org/W2356976736","https://openalex.org/W2374418939"],"related_works":["https://openalex.org/W2123347913","https://openalex.org/W2112490563","https://openalex.org/W1546843494","https://openalex.org/W4285306584","https://openalex.org/W2137633995","https://openalex.org/W2051546191","https://openalex.org/W2351730584","https://openalex.org/W2900543733","https://openalex.org/W2367313724","https://openalex.org/W2113871409"],"abstract_inverted_index":{"In":[0],"Substation":[1],"Automation":[2],"System":[3],"(SAS)":[4],"using":[5],"IEC":[6],"61850":[7],"protocol,":[8],"protection":[9,39],"system":[10],"is":[11,29],"facing":[12],"with":[13],"risk":[14],"of":[15,20,46],"mis-operation":[16],"due":[17],"to":[18,34],"mal-function":[19],"Electronics":[21],"Instrument":[22],"Transducers":[23],"(EITs).":[24],"A":[25],"rule":[26],"based":[27],"approach":[28],"proposed":[30,48],"in":[31],"the":[32,44,47],"letter":[33],"facilitate":[35],"a":[36],"fault":[37],"tolerant":[38],"system.":[40],"Numerical":[41],"simulation":[42],"shows":[43],"effectiveness":[45],"approach.":[49]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
