{"id":"https://openalex.org/W2064089727","doi":"https://doi.org/10.1109/ias.2010.5616819","title":"Different Factors Affecting Short Circuit Behavior of a Wind Power Plant","display_name":"Different Factors Affecting Short Circuit Behavior of a Wind Power Plant","publication_year":2010,"publication_date":"2010-10-01","ids":{"openalex":"https://openalex.org/W2064089727","doi":"https://doi.org/10.1109/ias.2010.5616819","mag":"2064089727"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2010.5616819","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5616819","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079561820","display_name":"Eduard Muljadi","orcid":"https://orcid.org/0000-0002-0821-8317"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"E. Muljadi","raw_affiliation_strings":["NREL, Golden, CO, USA","NREL,Golden,CO,USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NREL, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]},{"raw_affiliation_string":"NREL,Golden,CO,USA","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5041722330","display_name":"Nader Samaan","orcid":"https://orcid.org/0000-0001-9478-3007"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"N. Samaan","raw_affiliation_strings":["PNNL, Richland, WA, USA","[PNNL, Richland, WA, USA]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"PNNL, Richland, WA, USA","institution_ids":[]},{"raw_affiliation_string":"[PNNL, Richland, WA, USA]","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075261389","display_name":"Vahan Gevorgian","orcid":"https://orcid.org/0000-0003-4206-075X"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"V. Gevorgian","raw_affiliation_strings":["NREL, Golden, CO, USA","NREL,Golden,CO,USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NREL, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]},{"raw_affiliation_string":"NREL,Golden,CO,USA","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047457013","display_name":"Jionghao Li","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Li","raw_affiliation_strings":["EnerNex Corporation, Knoxville, TN, USA","EnerNex Corp., Knoxville, TN, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"EnerNex Corporation, Knoxville, TN, USA","institution_ids":[]},{"raw_affiliation_string":"EnerNex Corp., Knoxville, TN, USA","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080379811","display_name":"S. V. Pasupulati","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"S. Pasupulati","raw_affiliation_strings":["OCES, Inc., Mojave, CA, USA","OCES Inc., Mojave, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"OCES, Inc., Mojave, CA, USA","institution_ids":[]},{"raw_affiliation_string":"OCES Inc., Mojave, CA, USA","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.354,"has_fulltext":false,"cited_by_count":25,"citation_normalized_percentile":{"value":0.89101442,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10680","display_name":"Wind Energy Research and Development","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.7209783792495728},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.6406391263008118},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.6147278547286987},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5759932994842529},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5539758801460266},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.51572185754776},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.5107376575469971},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.4964213967323303},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.45844152569770813},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3414214551448822},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.09077438712120056}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.7209783792495728},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.6406391263008118},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6147278547286987},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5759932994842529},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5539758801460266},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.51572185754776},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.5107376575469971},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.4964213967323303},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.45844152569770813},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3414214551448822},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.09077438712120056}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias.2010.5616819","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5616819","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W1557691862","https://openalex.org/W2069713690","https://openalex.org/W2097340349","https://openalex.org/W2097662882","https://openalex.org/W2106877452","https://openalex.org/W2107295539","https://openalex.org/W2110435344","https://openalex.org/W2125480212","https://openalex.org/W2132321409","https://openalex.org/W2139071662","https://openalex.org/W2153730736","https://openalex.org/W4233618399"],"related_works":["https://openalex.org/W4398198689","https://openalex.org/W2354365353","https://openalex.org/W1988437325","https://openalex.org/W2811287415","https://openalex.org/W2354835317","https://openalex.org/W2130152888","https://openalex.org/W2003918017","https://openalex.org/W2171140818","https://openalex.org/W2906102508","https://openalex.org/W4243722550"],"abstract_inverted_index":{"A":[0,15],"wind":[1,61,103,121,132],"power":[2,62,122],"plant":[3,40,63,77,123],"consists":[4],"of":[5,9,60,75,102,119,127,131],"a":[6,31,120],"large":[7],"number":[8],"turbines":[10,37],"interconnected":[11],"by":[12],"underground":[13],"cable.":[14],"pad-mount":[16],"transformer":[17,46,136],"at":[18,149],"each":[19],"turbine":[20,104,133],"steps":[21],"up":[22,52],"the":[23,39,44,48,54,70,76,79,96,108,115,135,139,156],"voltage":[24,27,33,49,147],"from":[25],"generating":[26,110],"(690":[28],"V)":[29],"to":[30,43,53,68,91,95],"medium":[32],"(34.5":[34],"kV).":[35],"All":[36],"in":[38],"are":[41],"connected":[42],"substation":[45],"where":[47],"is":[50,67],"stepped":[51],"transmission":[55,80],"level.":[56],"An":[57],"important":[58],"aspect":[59],"(WPP)":[64],"impact":[65,130],"studies":[66],"evaluate":[69],"short-circuit":[71],"(SC)":[72],"current":[73],"contribution":[74],"into":[78],"network":[81],"under":[82],"different":[83,100,125,150],"fault":[84],"conditions.":[85],"This":[86,112],"task":[87],"can":[88],"be":[89,144,153,161],"challenging":[90],"protection":[92],"engineers":[93],"due":[94],"topology":[97],"differences":[98],"between":[99],"types":[101,126],"generators":[105],"(WTGs)":[106],"and":[107,138],"conventional":[109],"units.":[111],"paper":[113],"investigates":[114],"short":[116],"circuit":[117],"behavior":[118],"for":[124],"faults.":[128],"The":[129,146],"types,":[134],"configuration,":[137],"reactive":[140],"compensation":[141],"capacitor":[142],"will":[143,152,160],"investigated.":[145],"response":[148],"buses":[151],"observed.":[154],"Finally,":[155],"SC":[157],"line":[158],"currents":[159],"presented":[162],"along":[163],"with":[164],"its":[165],"symmetrical":[166],"components.":[167]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":3},{"year":2012,"cited_by_count":6}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
