{"id":"https://openalex.org/W2055314777","doi":"https://doi.org/10.1109/ias.2010.5615309","title":"A Series Voltage Regulator based on Quasi-Sinusoidal Waveform to Achieve Smart-Grid Requirements","display_name":"A Series Voltage Regulator based on Quasi-Sinusoidal Waveform to Achieve Smart-Grid Requirements","publication_year":2010,"publication_date":"2010-10-01","ids":{"openalex":"https://openalex.org/W2055314777","doi":"https://doi.org/10.1109/ias.2010.5615309","mag":"2055314777"},"language":"en","primary_location":{"id":"doi:10.1109/ias.2010.5615309","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5615309","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057705670","display_name":"Igor A. Pires","orcid":"https://orcid.org/0000-0002-8442-0074"},"institutions":[{"id":"https://openalex.org/I110200422","display_name":"Universidade Federal de Minas Gerais","ror":"https://ror.org/0176yjw32","country_code":"BR","type":"education","lineage":["https://openalex.org/I110200422"]},{"id":"https://openalex.org/I3018999404","display_name":"Centro Universit\u00e1rio de Belo Horizonte","ror":"https://ror.org/04m3xd186","country_code":"BR","type":"education","lineage":["https://openalex.org/I3018999404"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Igor Amariz Pires","raw_affiliation_strings":["Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil","Univ. Fed. de Minas Gerais, Belo Horizonte, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil","institution_ids":["https://openalex.org/I110200422"]},{"raw_affiliation_string":"Univ. Fed. de Minas Gerais, Belo Horizonte, Brazil","institution_ids":["https://openalex.org/I3018999404"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033396128","display_name":"Braz J. Cardoso Filho","orcid":"https://orcid.org/0000-0002-3470-4570"},"institutions":[{"id":"https://openalex.org/I110200422","display_name":"Universidade Federal de Minas Gerais","ror":"https://ror.org/0176yjw32","country_code":"BR","type":"education","lineage":["https://openalex.org/I110200422"]},{"id":"https://openalex.org/I3018999404","display_name":"Centro Universit\u00e1rio de Belo Horizonte","ror":"https://ror.org/04m3xd186","country_code":"BR","type":"education","lineage":["https://openalex.org/I3018999404"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Braz de Jesus Cardoso Filho","raw_affiliation_strings":["Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil","Univ. Fed. de Minas Gerais, Belo Horizonte, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil","institution_ids":["https://openalex.org/I110200422"]},{"raw_affiliation_string":"Univ. Fed. de Minas Gerais, Belo Horizonte, Brazil","institution_ids":["https://openalex.org/I3018999404"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100647837","display_name":"Jos\u00e9 Carlos de Oliveira","orcid":"https://orcid.org/0000-0002-5825-317X"},"institutions":[{"id":"https://openalex.org/I80850581","display_name":"Universidade Federal de Uberl\u00e2ndia","ror":"https://ror.org/04x3wvr31","country_code":"BR","type":"education","lineage":["https://openalex.org/I80850581"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Jose Carlos de Oliveira","raw_affiliation_strings":["Universidade Federal de Uberl\u00e2andia, Uberlandia, Minas Gerais, Brazil","Univ. Fed. Uberlandia, Uberlandia, Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universidade Federal de Uberl\u00e2andia, Uberlandia, Minas Gerais, Brazil","institution_ids":["https://openalex.org/I80850581"]},{"raw_affiliation_string":"Univ. Fed. Uberlandia, Uberlandia, Brazil","institution_ids":["https://openalex.org/I80850581"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2943,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.63782347,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"16","issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9922999739646912,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-compensation","display_name":"Voltage compensation","score":0.6387051939964294},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.6327738165855408},{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.6255625486373901},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6255060434341431},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5848191380500793},{"id":"https://openalex.org/keywords/low-dropout-regulator","display_name":"Low-dropout regulator","score":0.52399080991745},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.5212453007698059},{"id":"https://openalex.org/keywords/disturbance-voltage","display_name":"Disturbance voltage","score":0.5108703970909119},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.508126974105835},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5026779174804688},{"id":"https://openalex.org/keywords/total-harmonic-distortion","display_name":"Total harmonic distortion","score":0.49785661697387695},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.4676092863082886},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.4668971002101898},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4666796922683716},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4236024022102356},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3959922194480896},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38689783215522766},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3394473195075989},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.06945902109146118}],"concepts":[{"id":"https://openalex.org/C2777042706","wikidata":"https://www.wikidata.org/wiki/Q7940740","display_name":"Voltage compensation","level":3,"score":0.6387051939964294},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.6327738165855408},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.6255625486373901},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6255060434341431},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5848191380500793},{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.52399080991745},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.5212453007698059},{"id":"https://openalex.org/C153011079","wikidata":"https://www.wikidata.org/wiki/Q5283583","display_name":"Disturbance voltage","level":5,"score":0.5108703970909119},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.508126974105835},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5026779174804688},{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.49785661697387695},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.4676092863082886},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.4668971002101898},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4666796922683716},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4236024022102356},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3959922194480896},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38689783215522766},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3394473195075989},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.06945902109146118},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ias.2010.5615309","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ias.2010.5615309","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2010 IEEE Industry Applications Society Annual Meeting","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8199999928474426,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1647463343","https://openalex.org/W2114867294","https://openalex.org/W2122779635","https://openalex.org/W2126668795","https://openalex.org/W2148475071"],"related_works":["https://openalex.org/W4292868060","https://openalex.org/W1629251033","https://openalex.org/W2024816799","https://openalex.org/W1969429254","https://openalex.org/W3185987145","https://openalex.org/W2379548982","https://openalex.org/W1493009364","https://openalex.org/W1940273287","https://openalex.org/W2170704019","https://openalex.org/W2898176245"],"abstract_inverted_index":{"Smart-Grid":[0],"has":[1],"emerged":[2],"as":[3],"an":[4],"important":[5],"requirement":[6],"to":[7,13,35,48,70],"achieve":[8],"high":[9],"quality":[10,21],"voltage":[11,43,50,96,103],"supplied":[12],"customers.":[14],"Within":[15],"the":[16,31,62,71,76,110,114,119,123],"context":[17],"of":[18,39],"general":[19],"power":[20],"indicators,":[22],"a":[23,41,92,100,107],"common":[24],"problem":[25],"found":[26],"in":[27,78],"distribution":[28],"systems":[29],"is":[30],"unbalanced":[32,80],"voltage.":[33],"Usually,":[34],"solve":[36],"this":[37,57,87,89],"type":[38],"disturbance,":[40],"step":[42],"regulator":[44,97],"can":[45,67],"be":[46,68],"used":[47],"obtain":[49],"amplitude":[51],"compensation.":[52],"However,":[53],"for":[54],"many":[55],"applications,":[56],"device":[58,112],"does":[59],"not":[60],"fulfill":[61],"required":[63],"smart-grid":[64],"needs.":[65],"This":[66],"attributed":[69],"slow":[72],"time":[73],"response":[74,94],"and":[75],"inefficacy":[77],"compensating":[79],"voltages":[81,116,121],"with":[82],"phase":[83],"jumps.":[84],"Focusing":[85],"on":[86,99],"subject,":[88],"paper":[90],"proposes":[91],"rapid":[93],"electronic":[95],"based":[98],"multilevel":[101],"series":[102],"compensator":[104],"topology.":[105],"Using":[106],"quasi-sinusoidal":[108],"waveform,":[109],"proposed":[111],"balances":[113],"supply":[115],"while":[117],"keeping":[118],"compensated":[120],"within":[122],"harmonic":[124],"distortion":[125],"limits.":[126]},"counts_by_year":[{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2013,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
