{"id":"https://openalex.org/W3176908151","doi":"https://doi.org/10.1109/i2mtc50364.2021.9459837","title":"A Microcontroller based Charge Balanced Trapezoidal Stimulus Generator for FES System","display_name":"A Microcontroller based Charge Balanced Trapezoidal Stimulus Generator for FES System","publication_year":2021,"publication_date":"2021-05-17","ids":{"openalex":"https://openalex.org/W3176908151","doi":"https://doi.org/10.1109/i2mtc50364.2021.9459837","mag":"3176908151"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc50364.2021.9459837","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc50364.2021.9459837","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5053791639","display_name":"Bijit Basumatary","orcid":"https://orcid.org/0000-0002-2994-8562"},"institutions":[{"id":"https://openalex.org/I119241673","display_name":"Indian Institute of Technology Ropar","ror":"https://ror.org/02qkhhn56","country_code":"IN","type":"education","lineage":["https://openalex.org/I119241673"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Bijit Basumatary","raw_affiliation_strings":["Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India"],"affiliations":[{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","institution_ids":["https://openalex.org/I119241673"]},{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India","institution_ids":["https://openalex.org/I119241673"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062572013","display_name":"Rajat Suvra Halder","orcid":"https://orcid.org/0000-0001-6619-1979"},"institutions":[{"id":"https://openalex.org/I119241673","display_name":"Indian Institute of Technology Ropar","ror":"https://ror.org/02qkhhn56","country_code":"IN","type":"education","lineage":["https://openalex.org/I119241673"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rajat Suvra Halder","raw_affiliation_strings":["Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India"],"affiliations":[{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","institution_ids":["https://openalex.org/I119241673"]},{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India","institution_ids":["https://openalex.org/I119241673"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5088975480","display_name":"Ashish Kumar Sahani","orcid":"https://orcid.org/0000-0001-9173-3856"},"institutions":[{"id":"https://openalex.org/I119241673","display_name":"Indian Institute of Technology Ropar","ror":"https://ror.org/02qkhhn56","country_code":"IN","type":"education","lineage":["https://openalex.org/I119241673"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ashish Sahani","raw_affiliation_strings":["Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India"],"affiliations":[{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology,Ropar,India","institution_ids":["https://openalex.org/I119241673"]},{"raw_affiliation_string":"Center for Biomedical Engineering, Indian Institute of Technology, Ropar, India","institution_ids":["https://openalex.org/I119241673"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5053791639"],"corresponding_institution_ids":["https://openalex.org/I119241673"],"apc_list":null,"apc_paid":null,"fwci":0.5121,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.56626441,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microcontroller","display_name":"Microcontroller","score":0.6631914973258972},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5068288445472717},{"id":"https://openalex.org/keywords/functional-electrical-stimulation","display_name":"Functional electrical stimulation","score":0.4954313039779663},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.4943535327911377},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.47511014342308044},{"id":"https://openalex.org/keywords/amplitude","display_name":"Amplitude","score":0.42916324734687805},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.4261569380760193},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42115887999534607},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.390857458114624},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33404824137687683},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.28081607818603516},{"id":"https://openalex.org/keywords/stimulation","display_name":"Stimulation","score":0.23402109742164612},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.16881734132766724},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.10217803716659546}],"concepts":[{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.6631914973258972},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5068288445472717},{"id":"https://openalex.org/C2777766275","wikidata":"https://www.wikidata.org/wiki/Q1327643","display_name":"Functional electrical stimulation","level":3,"score":0.4954313039779663},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.4943535327911377},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.47511014342308044},{"id":"https://openalex.org/C180205008","wikidata":"https://www.wikidata.org/wiki/Q159190","display_name":"Amplitude","level":2,"score":0.42916324734687805},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.4261569380760193},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42115887999534607},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.390857458114624},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33404824137687683},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.28081607818603516},{"id":"https://openalex.org/C24998067","wikidata":"https://www.wikidata.org/wiki/Q4114622","display_name":"Stimulation","level":2,"score":0.23402109742164612},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.16881734132766724},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.10217803716659546},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C169760540","wikidata":"https://www.wikidata.org/wiki/Q207011","display_name":"Neuroscience","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc50364.2021.9459837","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc50364.2021.9459837","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W2004836665","https://openalex.org/W2009460222","https://openalex.org/W2024863474","https://openalex.org/W2029446273","https://openalex.org/W2037755721","https://openalex.org/W2042728692","https://openalex.org/W2115531508","https://openalex.org/W2122476058","https://openalex.org/W2125739137","https://openalex.org/W2150346569","https://openalex.org/W2160827929","https://openalex.org/W2172269986","https://openalex.org/W2236393967","https://openalex.org/W3013102553"],"related_works":["https://openalex.org/W4316095964","https://openalex.org/W2098278563","https://openalex.org/W3097292012","https://openalex.org/W2383001583","https://openalex.org/W2970187567","https://openalex.org/W2166727663","https://openalex.org/W2771395446","https://openalex.org/W2936477999","https://openalex.org/W2131084560","https://openalex.org/W3112038843"],"abstract_inverted_index":{"Foot":[0],"drop":[1],"(FD)":[2],"is":[3,41,148],"the":[4,8,12,15,19,24,47,52,65,130,145],"inability":[5],"to":[6,21,114],"lift":[7],"front":[9],"part":[10],"of":[11,44,64,71,129,144],"foot":[13],"from":[14],"ground.":[16],"It":[17,55],"causes":[18],"toes":[20],"drag":[22],"along":[23],"ground":[25],"while":[26],"walking":[27],"and":[28,32,51,76,120,127,151],"can":[29,56,133,152],"cause":[30],"fall":[31],"injuries.":[33],"A":[34],"patient":[35],"may":[36],"have":[37],"FD":[38],"when":[39],"there":[40],"a":[42,72,84,105,110],"loss":[43],"communication":[45],"between":[46],"central":[48],"nervous":[49],"system":[50,88,147],"peroneal":[53,66],"nerve.":[54],"be":[57,135,153],"corrected":[58],"by":[59,68,137],"functional":[60],"electrical":[61],"stimulation":[62,131],"(FES)":[63],"nerve":[67],"applying":[69],"pulses":[70],"given":[73],"duration,":[74],"amplitude,":[75,124],"frequency.":[77],"In":[78,100],"this":[79,101],"paper,":[80],"we":[81,103],"are":[82],"proposing":[83],"microcontroller":[85,108],"based":[86],"FES":[87],"that":[89],"produces":[90],"trapezoidal,":[91],"charge-balanced,":[92],"biphasic":[93,115],"stimulus":[94],"output":[95],"with":[96,109],"near-zero":[97],"DC":[98],"level.":[99],"design,":[102],"use":[104],"programmable":[106],"ESP32":[107],"built-in":[111],"DAC,":[112],"uniphasic":[113],"converter":[116],"circuit,":[117],"current":[118],"amplifier":[119],"step-up":[121],"transformer.":[122],"Stimulation":[123],"pulse":[125,132],"width":[126],"frequency":[128],"easily":[134],"adjusted":[136],"using":[138,155],"an":[139],"adjustable":[140],"knob.":[141],"The":[142],"cost":[143],"overall":[146],"very":[149],"low":[150],"built":[154],"standard":[156],"electronic":[157],"components.":[158]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
