{"id":"https://openalex.org/W2859697352","doi":"https://doi.org/10.1109/i2mtc.2018.8409698","title":"Automatic scale determination for adaptive windowing in Laser Speckle Imaging","display_name":"Automatic scale determination for adaptive windowing in Laser Speckle Imaging","publication_year":2018,"publication_date":"2018-05-01","ids":{"openalex":"https://openalex.org/W2859697352","doi":"https://doi.org/10.1109/i2mtc.2018.8409698","mag":"2859697352"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2018.8409698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2018.8409698","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5034708346","display_name":"Sergio A. Rosales-Nunez","orcid":"https://orcid.org/0000-0002-5122-6371"},"institutions":[{"id":"https://openalex.org/I39824353","display_name":"National Institute of Astrophysics, Optics and Electronics","ror":"https://ror.org/00bpmmc63","country_code":"MX","type":"facility","lineage":["https://openalex.org/I39824353"]}],"countries":["MX"],"is_corresponding":true,"raw_author_name":"Sergio A. Rosales-Nunez","raw_affiliation_strings":["Instituto Nacional de Astrofisica Optica y Electronica, Puebla, Puebla, MX"],"affiliations":[{"raw_affiliation_string":"Instituto Nacional de Astrofisica Optica y Electronica, Puebla, Puebla, MX","institution_ids":["https://openalex.org/I39824353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032036781","display_name":"Hayde Peregrina\u2010Barreto","orcid":"https://orcid.org/0000-0002-8623-091X"},"institutions":[{"id":"https://openalex.org/I39824353","display_name":"National Institute of Astrophysics, Optics and Electronics","ror":"https://ror.org/00bpmmc63","country_code":"MX","type":"facility","lineage":["https://openalex.org/I39824353"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"H. Peregrina-Barreto","raw_affiliation_strings":["Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico"],"affiliations":[{"raw_affiliation_string":"Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico","institution_ids":["https://openalex.org/I39824353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010423760","display_name":"Jose Rangel\u2010Magdaleno","orcid":"https://orcid.org/0000-0003-2785-5060"},"institutions":[{"id":"https://openalex.org/I39824353","display_name":"National Institute of Astrophysics, Optics and Electronics","ror":"https://ror.org/00bpmmc63","country_code":"MX","type":"facility","lineage":["https://openalex.org/I39824353"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"J. Rangel-Magdaleno","raw_affiliation_strings":["Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico"],"affiliations":[{"raw_affiliation_string":"Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico","institution_ids":["https://openalex.org/I39824353"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004970457","display_name":"Julio C. Ram\u0131\u0301rez-San-Juan","orcid":"https://orcid.org/0000-0002-4720-2668"},"institutions":[{"id":"https://openalex.org/I39824353","display_name":"National Institute of Astrophysics, Optics and Electronics","ror":"https://ror.org/00bpmmc63","country_code":"MX","type":"facility","lineage":["https://openalex.org/I39824353"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"J. C. Ramirez-San-Juan","raw_affiliation_strings":["Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico"],"affiliations":[{"raw_affiliation_string":"Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico","institution_ids":["https://openalex.org/I39824353"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109907645","display_name":"Iv\u00e1n R. Terol\u2010Villalobos","orcid":null},"institutions":[{"id":"https://openalex.org/I39824353","display_name":"National Institute of Astrophysics, Optics and Electronics","ror":"https://ror.org/00bpmmc63","country_code":"MX","type":"facility","lineage":["https://openalex.org/I39824353"]}],"countries":["MX"],"is_corresponding":false,"raw_author_name":"I. Terol-Villalobos","raw_affiliation_strings":["Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico"],"affiliations":[{"raw_affiliation_string":"Instituto Nacional de Astrofisica, Optica y Electronica, Puebla, Mexico","institution_ids":["https://openalex.org/I39824353"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5034708346"],"corresponding_institution_ids":["https://openalex.org/I39824353"],"apc_list":null,"apc_paid":null,"fwci":0.5422,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.66532192,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11109","display_name":"Thermoregulation and physiological responses","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11109","display_name":"Thermoregulation and physiological responses","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12994","display_name":"Infrared Thermography in Medicine","score":0.9832000136375427,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10427","display_name":"Visual perception and processing mechanisms","score":0.944599986076355,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/speckle-pattern","display_name":"Speckle pattern","score":0.9056118726730347},{"id":"https://openalex.org/keywords/speckle-noise","display_name":"Speckle noise","score":0.7321639657020569},{"id":"https://openalex.org/keywords/image-resolution","display_name":"Image resolution","score":0.687153697013855},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6607981324195862},{"id":"https://openalex.org/keywords/window","display_name":"Window (computing)","score":0.6014495491981506},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.587273359298706},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.5841184854507446},{"id":"https://openalex.org/keywords/contrast","display_name":"Contrast (vision)","score":0.5527302026748657},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.5132951140403748},{"id":"https://openalex.org/keywords/computation","display_name":"Computation","score":0.4670015573501587},{"id":"https://openalex.org/keywords/image","display_name":"Image (mathematics)","score":0.2552145719528198},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.16070327162742615}],"concepts":[{"id":"https://openalex.org/C102290492","wikidata":"https://www.wikidata.org/wiki/Q7575045","display_name":"Speckle pattern","level":2,"score":0.9056118726730347},{"id":"https://openalex.org/C180940675","wikidata":"https://www.wikidata.org/wiki/Q7575045","display_name":"Speckle noise","level":3,"score":0.7321639657020569},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.687153697013855},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6607981324195862},{"id":"https://openalex.org/C2778751112","wikidata":"https://www.wikidata.org/wiki/Q835016","display_name":"Window (computing)","level":2,"score":0.6014495491981506},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.587273359298706},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.5841184854507446},{"id":"https://openalex.org/C2776502983","wikidata":"https://www.wikidata.org/wiki/Q690182","display_name":"Contrast (vision)","level":2,"score":0.5527302026748657},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.5132951140403748},{"id":"https://openalex.org/C45374587","wikidata":"https://www.wikidata.org/wiki/Q12525525","display_name":"Computation","level":2,"score":0.4670015573501587},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.2552145719528198},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.16070327162742615},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2018.8409698","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2018.8409698","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W6340901","https://openalex.org/W1968396957","https://openalex.org/W1974674893","https://openalex.org/W1987834260","https://openalex.org/W2056314199","https://openalex.org/W2067811903","https://openalex.org/W2076035429","https://openalex.org/W2118901913","https://openalex.org/W2125741101","https://openalex.org/W2171502017","https://openalex.org/W2388574354","https://openalex.org/W2501907080","https://openalex.org/W2624764342","https://openalex.org/W6685410322","https://openalex.org/W6710882694"],"related_works":["https://openalex.org/W2065648684","https://openalex.org/W2009383287","https://openalex.org/W2042914788","https://openalex.org/W2182190754","https://openalex.org/W4321264664","https://openalex.org/W2121688719","https://openalex.org/W2016481886","https://openalex.org/W2055824452","https://openalex.org/W2727313114","https://openalex.org/W1989852278"],"abstract_inverted_index":{"Laser":[0],"Speckle":[1],"Imaging":[2],"(LSI)":[3],"is":[4,55,108],"a":[5,61,78,96,139],"useful":[6],"technique":[7],"in":[8,138],"medical":[9],"applications":[10],"since":[11],"it":[12,68],"provides":[13],"information":[14],"about":[15],"blood":[16,52,106],"flow":[17],"and":[18,92],"vascular.":[19],"Traditional":[20],"LSI":[21],"uses":[22],"standard":[23],"window":[24,63,80,97,133],"sizes":[25],"(5\u00d75":[26],"or":[27],"7\u00d77)":[28],"for":[29,135,149],"contrast":[30,136],"computing":[31],"without":[32],"taking":[33],"into":[34],"account":[35],"the":[36,39,47,51,58,71,75,83,86,102,105,109,115,131],"size":[37,98,103,134],"of":[38,88,104],"ROIs":[40],"(blood":[41],"vessels).":[42],"The":[43,142],"speckle":[44,72,140],"noise":[45,84],"affects":[46],"whole":[48],"image,":[49],"however,":[50],"vessel":[53,107],"region":[54],"smoother.":[56],"On":[57],"one":[59,110],"hand,":[60,77],"small":[62,93],"preserves":[64],"spatial":[65,90],"resolution":[66,91],"but":[67],"barely":[69],"attenuates":[70],"noise;":[73],"on":[74,126],"other":[76],"large":[79],"significantly":[81],"reduces":[82],"at":[85],"expense":[87],"losing":[89],"ROIs.":[94],"Therefore,":[95],"that":[99,111],"fits":[100],"with":[101,114,146],"can":[112],"deal":[113],"noise/resolution":[116],"trade-off":[117],"adequately.":[118],"This":[119],"paper":[120],"proposes":[121],"an":[122],"automatic":[123],"methodology,":[124],"based":[125],"granulometry":[127],"analysis,":[128],"to":[129],"estimate":[130],"accurate":[132],"computation":[137],"image.":[141],"results":[143],"are":[144],"compared":[145],"traditional":[147],"techniques":[148],"LSI.":[150]},"counts_by_year":[{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2018,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
