{"id":"https://openalex.org/W2849471016","doi":"https://doi.org/10.1109/i2mtc.2018.8409684","title":"Availability and variations of cardiac activity in the case of measuring the bioimpedance of wrist","display_name":"Availability and variations of cardiac activity in the case of measuring the bioimpedance of wrist","publication_year":2018,"publication_date":"2018-05-01","ids":{"openalex":"https://openalex.org/W2849471016","doi":"https://doi.org/10.1109/i2mtc.2018.8409684","mag":"2849471016"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2018.8409684","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2018.8409684","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039420992","display_name":"Margus Metshein","orcid":"https://orcid.org/0000-0001-5604-7674"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":true,"raw_author_name":"Margus Metshein","raw_affiliation_strings":["Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090276064","display_name":"Paul Annus","orcid":"https://orcid.org/0000-0002-4902-1289"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Paul Annus","raw_affiliation_strings":["Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075338248","display_name":"Raul Land","orcid":"https://orcid.org/0000-0003-0269-2808"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Raul Land","raw_affiliation_strings":["Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015375914","display_name":"Mart Min","orcid":"https://orcid.org/0000-0002-4952-4142"},"institutions":[{"id":"https://openalex.org/I111112146","display_name":"Tallinn University of Technology","ror":"https://ror.org/0443cwa12","country_code":"EE","type":"education","lineage":["https://openalex.org/I111112146"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Mart Min","raw_affiliation_strings":["Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia"],"affiliations":[{"raw_affiliation_string":"Th. J. Seebeck Dept. of Electronics, Tallinn University of Technology, Tallinn, Estonia","institution_ids":["https://openalex.org/I111112146"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057770174","display_name":"Alvo Aabloo","orcid":"https://orcid.org/0000-0002-0183-1282"},"institutions":[{"id":"https://openalex.org/I56085075","display_name":"University of Tartu","ror":"https://ror.org/03z77qz90","country_code":"EE","type":"education","lineage":["https://openalex.org/I56085075"]}],"countries":["EE"],"is_corresponding":false,"raw_author_name":"Alvo Aabloo","raw_affiliation_strings":["Institute of Technology University of Tartu, Tartu, Estonia"],"affiliations":[{"raw_affiliation_string":"Institute of Technology University of Tartu, Tartu, Estonia","institution_ids":["https://openalex.org/I56085075"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5039420992"],"corresponding_institution_ids":["https://openalex.org/I111112146"],"apc_list":null,"apc_paid":null,"fwci":0.4358,"has_fulltext":false,"cited_by_count":14,"citation_normalized_percentile":{"value":0.60498112,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wrist","display_name":"Wrist","score":0.7878868579864502},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.7353171110153198},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.6499740481376648},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.6295417547225952},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5945296287536621},{"id":"https://openalex.org/keywords/pulse-wave","display_name":"Pulse wave","score":0.5414772629737854},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5371459722518921},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.48369938135147095},{"id":"https://openalex.org/keywords/radial-artery","display_name":"Radial artery","score":0.42093268036842346},{"id":"https://openalex.org/keywords/pulse-wave-analysis","display_name":"Pulse Wave Analysis","score":0.4195021092891693},{"id":"https://openalex.org/keywords/focused-impedance-measurement","display_name":"Focused Impedance Measurement","score":0.4162146747112274},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2897499203681946},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.19084331393241882},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18826726078987122},{"id":"https://openalex.org/keywords/artery","display_name":"Artery","score":0.1858985424041748},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.18235042691230774},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.15291142463684082},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.14551937580108643},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.13748416304588318}],"concepts":[{"id":"https://openalex.org/C2778216619","wikidata":"https://www.wikidata.org/wiki/Q185706","display_name":"Wrist","level":2,"score":0.7878868579864502},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.7353171110153198},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.6499740481376648},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.6295417547225952},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5945296287536621},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.5414772629737854},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5371459722518921},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.48369938135147095},{"id":"https://openalex.org/C2778218979","wikidata":"https://www.wikidata.org/wiki/Q662857","display_name":"Radial artery","level":3,"score":0.42093268036842346},{"id":"https://openalex.org/C2908916285","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse Wave Analysis","level":4,"score":0.4195021092891693},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.4162146747112274},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2897499203681946},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.19084331393241882},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18826726078987122},{"id":"https://openalex.org/C2776820930","wikidata":"https://www.wikidata.org/wiki/Q9655","display_name":"Artery","level":2,"score":0.1858985424041748},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.18235042691230774},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.15291142463684082},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.14551937580108643},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.13748416304588318},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C134652429","wikidata":"https://www.wikidata.org/wiki/Q1052698","display_name":"Jitter","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2018.8409684","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2018.8409684","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321090","display_name":"Eesti Teadusagentuur","ror":"https://ror.org/00jjeja18"},{"id":"https://openalex.org/F4320332999","display_name":"Horizon 2020 Framework Programme","ror":"https://ror.org/00k4n6c32"},{"id":"https://openalex.org/F4320335322","display_name":"European Regional Development Fund","ror":"https://ror.org/00k4n6c32"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W2011060321","https://openalex.org/W2051564966","https://openalex.org/W2070890807","https://openalex.org/W2116881503","https://openalex.org/W2132863420","https://openalex.org/W2155408499","https://openalex.org/W2162498817","https://openalex.org/W2165907488","https://openalex.org/W2736490195","https://openalex.org/W6741010162"],"related_works":["https://openalex.org/W2080130032","https://openalex.org/W3086677680","https://openalex.org/W4232181702","https://openalex.org/W2172186597","https://openalex.org/W2357756881","https://openalex.org/W2048500805","https://openalex.org/W2218948273","https://openalex.org/W2039241848","https://openalex.org/W4308695532","https://openalex.org/W2362477685"],"abstract_inverted_index":{"The":[0,56,78],"utilization":[1],"of":[2,33,35,45,51,58,60,94,107,119,124],"technique":[3],"for":[4],"monitoring":[5],"pulse":[6,52,98],"wave":[7,53],"from":[8,54],"wrist":[9],"by":[10,97],"using":[11],"the":[12,31,36,40,49,61,82,90,105,113,122],"electrical":[13],"bioimpedance":[14],"has":[15],"been":[16],"implemented":[17],"in":[18,74,104,115],"this":[19],"paper.":[20],"A":[21],"four":[22],"electrode":[23,62,83],"printed":[24],"circuit":[25],"board":[26],"was":[27,67,84,102],"used":[28],"to":[29,64,86,89],"evaluate":[30],"influence":[32,57],"positioning":[34,59],"electrodes,":[37],"pressure":[38,80,123],"on":[39,48,81,109],"electrodes":[41],"and":[42],"individual":[43],"differences":[44],"several":[46,110],"volunteers":[47],"availability":[50],"wrist.":[55],"relative":[63],"radial":[65],"artery":[66],"verified":[68],"experimentally,":[69],"allowing":[70],"5":[71],"mm":[72],"shift":[73],"both":[75],"transverse":[76],"directions.":[77],"increasing":[79],"found":[85],"give":[87],"rise":[88],"time":[91,116],"varying":[92,117],"change":[93,118],"impedance,":[95],"caused":[96],"wave.":[99],"This":[100],"result":[101],"confirmed":[103],"case":[106],"measurements":[108],"volunteers,":[111],"proposing":[112],"convergence":[114],"impedance":[120],"above":[121],"400":[125],"g.":[126]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2}],"updated_date":"2025-11-16T23:07:24.559242","created_date":"2025-10-10T00:00:00"}