{"id":"https://openalex.org/W2736154107","doi":"https://doi.org/10.1109/i2mtc.2017.7969959","title":"Linearity error in Clamp-on ultrasonic flowmeters due to the installation on pipes made of dispersive materials","display_name":"Linearity error in Clamp-on ultrasonic flowmeters due to the installation on pipes made of dispersive materials","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2736154107","doi":"https://doi.org/10.1109/i2mtc.2017.7969959","mag":"2736154107"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2017.7969959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2017.7969959","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://hdl.handle.net/2117/112194","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040348210","display_name":"Oliver Mill\u00e1n-Blasco","orcid":"https://orcid.org/0000-0002-2544-5642"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":true,"raw_author_name":"Oliver Millan-Blasco","raw_affiliation_strings":["Universitat Politecnica de Catalunya, Barcelona, Catalunya, ES"],"affiliations":[{"raw_affiliation_string":"Universitat Politecnica de Catalunya, Barcelona, Catalunya, ES","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024112995","display_name":"Jordi Soler","orcid":"https://orcid.org/0000-0002-1340-2549"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Jordi Salazar","raw_affiliation_strings":["Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain"],"affiliations":[{"raw_affiliation_string":"Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066051180","display_name":"J.A. Ch\u00e1vez","orcid":"https://orcid.org/0000-0001-7255-5054"},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Juan A. Chavez","raw_affiliation_strings":["Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain"],"affiliations":[{"raw_affiliation_string":"Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045664669","display_name":"A. Tur\u00f3","orcid":null},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Antoni Turo","raw_affiliation_strings":["Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain"],"affiliations":[{"raw_affiliation_string":"Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103788238","display_name":"Miguel J. Garc\u00eda\u2010Hern\u00e1ndez","orcid":null},"institutions":[{"id":"https://openalex.org/I9617848","display_name":"Universitat Polit\u00e8cnica de Catalunya","ror":"https://ror.org/03mb6wj31","country_code":"ES","type":"education","lineage":["https://openalex.org/I9617848"]}],"countries":["ES"],"is_corresponding":false,"raw_author_name":"Miguel J. Garcia-Hernandez","raw_affiliation_strings":["Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain"],"affiliations":[{"raw_affiliation_string":"Sensor System Group. Department of Electronic Engineering, Universitat Polit\u00e8cnica de Catalunya, Barcelona, Spain","institution_ids":["https://openalex.org/I9617848"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5040348210"],"corresponding_institution_ids":["https://openalex.org/I9617848"],"apc_list":null,"apc_paid":null,"fwci":0.4649,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.62051315,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":96},"biblio":{"volume":"44","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ultrasonic-flow-meter","display_name":"Ultrasonic flow meter","score":0.8183290958404541},{"id":"https://openalex.org/keywords/ultrasonic-sensor","display_name":"Ultrasonic sensor","score":0.8071170449256897},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.7519394755363464},{"id":"https://openalex.org/keywords/linearity","display_name":"Linearity","score":0.6983848810195923},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.6362833976745605},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.6323559880256653},{"id":"https://openalex.org/keywords/wedge","display_name":"Wedge (geometry)","score":0.6104226112365723},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5617600679397583},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.5214264392852783},{"id":"https://openalex.org/keywords/ultrasonic-testing","display_name":"Ultrasonic testing","score":0.5057961940765381},{"id":"https://openalex.org/keywords/observational-error","display_name":"Observational error","score":0.43765005469322205},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2682284116744995},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.22899430990219116},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.2260248064994812},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.11512839794158936},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1123548150062561},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08127301931381226}],"concepts":[{"id":"https://openalex.org/C63066824","wikidata":"https://www.wikidata.org/wiki/Q2165466","display_name":"Ultrasonic flow meter","level":3,"score":0.8183290958404541},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.8071170449256897},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.7519394755363464},{"id":"https://openalex.org/C77170095","wikidata":"https://www.wikidata.org/wiki/Q1753188","display_name":"Linearity","level":2,"score":0.6983848810195923},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.6362833976745605},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.6323559880256653},{"id":"https://openalex.org/C47422493","wikidata":"https://www.wikidata.org/wiki/Q2755127","display_name":"Wedge (geometry)","level":2,"score":0.6104226112365723},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5617600679397583},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5214264392852783},{"id":"https://openalex.org/C139730468","wikidata":"https://www.wikidata.org/wiki/Q1779355","display_name":"Ultrasonic testing","level":3,"score":0.5057961940765381},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.43765005469322205},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2682284116744995},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.22899430990219116},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.2260248064994812},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.11512839794158936},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1123548150062561},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08127301931381226},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/i2mtc.2017.7969959","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2017.7969959","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},{"id":"pmh:oai:recercat.cat:2072/302817","is_oa":true,"landing_page_url":"http://hdl.handle.net/2117/112194","pdf_url":null,"source":{"id":"https://openalex.org/S4306402147","display_name":"RECERCAT (Consorci de Serveis Universitaris de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210090028","host_organization_name":"Consorci de Serveis Universitaris de Catalunya","host_organization_lineage":["https://openalex.org/I4210090028"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/publishedVersion"}],"best_oa_location":{"id":"pmh:oai:recercat.cat:2072/302817","is_oa":true,"landing_page_url":"http://hdl.handle.net/2117/112194","pdf_url":null,"source":{"id":"https://openalex.org/S4306402147","display_name":"RECERCAT (Consorci de Serveis Universitaris de Catalunya)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I4210090028","host_organization_name":"Consorci de Serveis Universitaris de Catalunya","host_organization_lineage":["https://openalex.org/I4210090028"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[{"score":0.7200000286102295,"display_name":"Clean water and sanitation","id":"https://metadata.un.org/sdg/6"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320334830","display_name":"Ag\u00e8ncia de Gesti\u00f3 d'Ajuts Universitaris i de Recerca","ror":"https://ror.org/01n4pqe45"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1532009595","https://openalex.org/W1969459774","https://openalex.org/W2060376504","https://openalex.org/W2132489092","https://openalex.org/W2149535448","https://openalex.org/W2548622925","https://openalex.org/W2750806296","https://openalex.org/W6631860286","https://openalex.org/W6744117173"],"related_works":["https://openalex.org/W2371824631","https://openalex.org/W2350425252","https://openalex.org/W2906209913","https://openalex.org/W2351040364","https://openalex.org/W2354654388","https://openalex.org/W2005252818","https://openalex.org/W2380694726","https://openalex.org/W2027530913","https://openalex.org/W1991603422","https://openalex.org/W2371428681"],"abstract_inverted_index":{"This":[0,24,142],"article":[1],"analyses":[2],"and":[3,41,74,184],"explains":[4],"the":[5,12,36,97,101,104,137,146,150,155,165,178,191,211,213,217],"implications":[6],"that":[7,103],"dispersive":[8,30,110,170,208],"materials":[9,31],"have":[10,86],"over":[11],"linearity":[13,192],"in":[14,35,127,174,204],"flow":[15,61,76],"measurement":[16,77],"when":[17],"a":[18,59,65,81,121,159,169,199,207],"Clamp-on":[19,67],"ultrasonic":[20,68,116,151,166],"flowmeter":[21,69,117,152,167],"is":[22,25,107,221],"used.":[23],"of":[26,38,45,58,109,124,149,163,201,206],"capital":[27],"importance":[28],"because":[29],"are":[32],"commonly":[33],"used":[34,55],"manufacture":[37],"transducer":[39,105],"wedges":[40],"pipes.":[42],"The":[43,54],"evaluation":[44],"this":[46,113,128,189],"phenomenon":[47],"has":[48],"been":[49,87],"tested":[50],"by":[51,100,136,154],"experimental":[52],"measurement.":[53],"setup":[56],"consisted":[57,162],"water":[60],"calibration":[62],"facility":[63],"where":[64],"commercial":[66],"was":[70,78,92,118,139,194],"installed":[71,119],"on":[72,120,168],"it":[73,197],"its":[75],"compared":[79],"with":[80,145],"reference":[82],"flowmeter.":[83],"Two":[84],"experiments":[85],"conducted.":[88],"A":[89],"first":[90],"experiment":[91,161],"performed":[93],"to":[94,176],"evaluate":[95],"only":[96],"effect":[98],"produced":[99],"fact":[102],"wedge":[106,138,183],"made":[108,123],"material.":[111],"For":[112],"reason,":[114],"an":[115,130],"pipe":[122,171,214],"non-dispersive":[125],"material,":[126],"case,":[129],"INOX":[131],"pipe.":[132],"Linearity":[133],"error":[134,143,193,220],"introduced":[135],"below":[140],"1%.":[141],"complies":[144],"accuracy":[147],"specification":[148],"given":[153],"manufacturer":[156],"(\u00b11.5%).":[157],"Finally,":[158],"second":[160],"installing":[164],"(PVC":[172],"pipe)":[173],"order":[175],"measure":[177],"worst":[179],"condition":[180],"(both":[181],"materials,":[182],"pipe,":[185,210],"were":[186],"dispersive).":[187],"Under":[188],"condition,":[190],"increased":[195],"until":[196],"reaches":[198],"value":[200],"6.4%.":[202],"Moreover,":[203],"case":[205],"material":[209],"bigger":[212,218],"thickness":[215],"is,":[216],"non-linearity":[219],"reached.":[222]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2017,"cited_by_count":2}],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}
