{"id":"https://openalex.org/W2734974298","doi":"https://doi.org/10.1109/i2mtc.2017.7969689","title":"A three-core power cable online monitoring system based on phase current sensing","display_name":"A three-core power cable online monitoring system based on phase current sensing","publication_year":2017,"publication_date":"2017-05-01","ids":{"openalex":"https://openalex.org/W2734974298","doi":"https://doi.org/10.1109/i2mtc.2017.7969689","mag":"2734974298"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2017.7969689","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2017.7969689","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109114156","display_name":"Yanling Yuan","orcid":null},"institutions":[{"id":"https://openalex.org/I154341788","display_name":"Tangshan College","ror":"https://ror.org/00rfn0469","country_code":"CN","type":"education","lineage":["https://openalex.org/I154341788"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanling Yuan","raw_affiliation_strings":["Tangshan Electrical Power Company, Tangshan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tangshan Electrical Power Company, Tangshan, China","institution_ids":["https://openalex.org/I154341788"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040091864","display_name":"Jie Dong","orcid":"https://orcid.org/0000-0002-5742-511X"},"institutions":[{"id":"https://openalex.org/I154341788","display_name":"Tangshan College","ror":"https://ror.org/00rfn0469","country_code":"CN","type":"education","lineage":["https://openalex.org/I154341788"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jie Dong","raw_affiliation_strings":["Tangshan Electrical Power Company, Tangshan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tangshan Electrical Power Company, Tangshan, China","institution_ids":["https://openalex.org/I154341788"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039561878","display_name":"Jingfu Gan","orcid":null},"institutions":[{"id":"https://openalex.org/I154341788","display_name":"Tangshan College","ror":"https://ror.org/00rfn0469","country_code":"CN","type":"education","lineage":["https://openalex.org/I154341788"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jingfu Gan","raw_affiliation_strings":["Tangshan Electrical Power Company, Tangshan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tangshan Electrical Power Company, Tangshan, China","institution_ids":["https://openalex.org/I154341788"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005461275","display_name":"Shisong Li","orcid":"https://orcid.org/0000-0002-2509-5523"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shisong Li","raw_affiliation_strings":["Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009949085","display_name":"Wei Zhao","orcid":"https://orcid.org/0000-0002-3679-6165"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wei Zhao","raw_affiliation_strings":["Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100432868","display_name":"Songling Huang","orcid":"https://orcid.org/0000-0003-4442-2566"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Songling Huang","raw_affiliation_strings":["Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100333507","display_name":"Lei Chen","orcid":"https://orcid.org/0000-0002-7918-8936"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Lei Chen","raw_affiliation_strings":["Department of Electrical Engineering, Tsinghua University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1462,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.50656643,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9900000095367432,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11850","display_name":"Concrete Corrosion and Durability","score":0.9527999758720398,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power-cable","display_name":"Power cable","score":0.7642354965209961},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.6696351170539856},{"id":"https://openalex.org/keywords/electromagnetic-shielding","display_name":"Electromagnetic shielding","score":0.620253324508667},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5700618624687195},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5456207394599915},{"id":"https://openalex.org/keywords/direct-buried-cable","display_name":"Direct-buried cable","score":0.5400590896606445},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.5119777917861938},{"id":"https://openalex.org/keywords/core","display_name":"Core (optical fiber)","score":0.5037590861320496},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.4891383945941925},{"id":"https://openalex.org/keywords/three-phase","display_name":"Three-phase","score":0.4287107586860657},{"id":"https://openalex.org/keywords/phase","display_name":"Phase (matter)","score":0.4268898665904999},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.4258701205253601},{"id":"https://openalex.org/keywords/magnetic-core","display_name":"Magnetic core","score":0.4128808081150055},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.40999317169189453},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3866456151008606},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.21833032369613647},{"id":"https://openalex.org/keywords/cable-harness","display_name":"Cable harness","score":0.2119448482990265},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.15242865681648254},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.15171176195144653},{"id":"https://openalex.org/keywords/cable-gland","display_name":"Cable gland","score":0.1198834776878357},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.11369878053665161}],"concepts":[{"id":"https://openalex.org/C2777772068","wikidata":"https://www.wikidata.org/wiki/Q1939150","display_name":"Power cable","level":3,"score":0.7642354965209961},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6696351170539856},{"id":"https://openalex.org/C2265751","wikidata":"https://www.wikidata.org/wiki/Q332007","display_name":"Electromagnetic shielding","level":2,"score":0.620253324508667},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5700618624687195},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5456207394599915},{"id":"https://openalex.org/C137802790","wikidata":"https://www.wikidata.org/wiki/Q5280219","display_name":"Direct-buried cable","level":5,"score":0.5400590896606445},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.5119777917861938},{"id":"https://openalex.org/C2164484","wikidata":"https://www.wikidata.org/wiki/Q5170150","display_name":"Core (optical fiber)","level":2,"score":0.5037590861320496},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4891383945941925},{"id":"https://openalex.org/C173871940","wikidata":"https://www.wikidata.org/wiki/Q471846","display_name":"Three-phase","level":3,"score":0.4287107586860657},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.4268898665904999},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.4258701205253601},{"id":"https://openalex.org/C23832930","wikidata":"https://www.wikidata.org/wiki/Q1088161","display_name":"Magnetic core","level":3,"score":0.4128808081150055},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.40999317169189453},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3866456151008606},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.21833032369613647},{"id":"https://openalex.org/C180761244","wikidata":"https://www.wikidata.org/wiki/Q354262","display_name":"Cable harness","level":3,"score":0.2119448482990265},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.15242865681648254},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.15171176195144653},{"id":"https://openalex.org/C110925319","wikidata":"https://www.wikidata.org/wiki/Q12855","display_name":"Cable gland","level":2,"score":0.1198834776878357},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.11369878053665161},{"id":"https://openalex.org/C2779227376","wikidata":"https://www.wikidata.org/wiki/Q6505497","display_name":"Layer (electronics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C59399137","wikidata":"https://www.wikidata.org/wiki/Q1327423","display_name":"Cable theory","level":4,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2017.7969689","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2017.7969689","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1923674255","https://openalex.org/W1925969344","https://openalex.org/W1987548017","https://openalex.org/W1988028825","https://openalex.org/W2024681446","https://openalex.org/W2096518574","https://openalex.org/W2115789627","https://openalex.org/W2119537818","https://openalex.org/W2124408286","https://openalex.org/W2152420534","https://openalex.org/W2157060392","https://openalex.org/W2157251993","https://openalex.org/W2166252671"],"related_works":["https://openalex.org/W2105336176","https://openalex.org/W3205846463","https://openalex.org/W1986443001","https://openalex.org/W2062448018","https://openalex.org/W1606843432","https://openalex.org/W2381117993","https://openalex.org/W1932015378","https://openalex.org/W3014178197","https://openalex.org/W2375767467","https://openalex.org/W2599586526"],"abstract_inverted_index":{"The":[0],"three-core":[1,25,49,92,136],"power":[2,26,50,93,105,116,137,150],"cable":[3,27,51,106,138,151],"shares":[4],"one":[5],"single":[6],"shielding":[7],"with":[8],"three":[9,61,99,111],"phase":[10,87,112,126,131],"cores.":[11],"Since":[12],"it":[13],"requires":[14],"a":[15,48,82,91,96,120,135,149],"lower":[16],"voltage":[17],"insulation":[18],"and":[19,65,108],"is":[20,52,63,142],"generally":[21],"less":[22],"expensive,":[23],"the":[24,33,45,57,104,115,125,146],"has":[28],"been":[29],"widely":[30],"used":[31],"in":[32,54],"electrical":[34],"energy":[35],"transmission":[36],"project":[37],"below":[38],"35kV.":[39],"A":[40],"known":[41],"problem":[42],"for":[43,86,144],"sensing":[44],"current":[46,59,69,88,132],"of":[47,60,90,114,124,148],"that":[53],"steady":[55],"state":[56],"total":[58],"phases":[62],"zero,":[64],"therefore":[66],"traditional":[67],"inductive":[68],"measurement":[70,89,133],"methods":[71],"will":[72],"be":[73],"invalid.":[74],"To":[75],"solve":[76],"this":[77,79,130],"problem,":[78],"paper":[80],"presents":[81],"magnetic":[83,100,122],"sensor":[84],"array":[85],"cable.":[94],"In":[95],"simplest":[97],"approach,":[98],"sensors,":[101],"installed":[102],"on":[103,129],"surface":[107],"aligned":[109],"to":[110],"cores":[113],"cable,":[117],"can":[118],"have":[119],"linear":[121],"response":[123],"current.":[127],"Based":[128],"technique,":[134],"online":[139],"monitoring":[140],"system":[141],"proposed":[143],"improving":[145],"reliability":[147],"system.":[152]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
