{"id":"https://openalex.org/W2503112311","doi":"https://doi.org/10.1109/i2mtc.2016.7520339","title":"Modeling the measurement error of energy meter using NARX model","display_name":"Modeling the measurement error of energy meter using NARX model","publication_year":2016,"publication_date":"2016-05-01","ids":{"openalex":"https://openalex.org/W2503112311","doi":"https://doi.org/10.1109/i2mtc.2016.7520339","mag":"2503112311"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2016.7520339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2016.7520339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5078999829","display_name":"Supriya Jaiswal","orcid":"https://orcid.org/0000-0003-1696-1263"},"institutions":[{"id":"https://openalex.org/I167153416","display_name":"Visvesvaraya National Institute of Technology","ror":"https://ror.org/02zrtpp84","country_code":"IN","type":"education","lineage":["https://openalex.org/I167153416"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Supriya Jaiswal","raw_affiliation_strings":["Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India","institution_ids":["https://openalex.org/I167153416"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006230267","display_name":"Manish Ganesh Wath","orcid":null},"institutions":[{"id":"https://openalex.org/I167153416","display_name":"Visvesvaraya National Institute of Technology","ror":"https://ror.org/02zrtpp84","country_code":"IN","type":"education","lineage":["https://openalex.org/I167153416"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"M.G. Wath","raw_affiliation_strings":["Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India","institution_ids":["https://openalex.org/I167153416"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087811618","display_name":"Makarand S. Ballal","orcid":"https://orcid.org/0000-0002-9451-4576"},"institutions":[{"id":"https://openalex.org/I167153416","display_name":"Visvesvaraya National Institute of Technology","ror":"https://ror.org/02zrtpp84","country_code":"IN","type":"education","lineage":["https://openalex.org/I167153416"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Makarand S. Ballal","raw_affiliation_strings":["Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Visvesvaraya National Institute of Technology, Nagpur, India","institution_ids":["https://openalex.org/I167153416"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.3501,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.82461748,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"56","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11236","display_name":"Control Systems and Identification","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9915000200271606,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nonlinear-autoregressive-exogenous-model","display_name":"Nonlinear autoregressive exogenous model","score":0.914946436882019},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.719832718372345},{"id":"https://openalex.org/keywords/metering-mode","display_name":"Metering mode","score":0.6299631595611572},{"id":"https://openalex.org/keywords/autoregressive-model","display_name":"Autoregressive model","score":0.5936384797096252},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5803629755973816},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.5774564743041992},{"id":"https://openalex.org/keywords/parametric-model","display_name":"Parametric model","score":0.544126570224762},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5153433680534363},{"id":"https://openalex.org/keywords/parametric-statistics","display_name":"Parametric statistics","score":0.5116482377052307},{"id":"https://openalex.org/keywords/observational-error","display_name":"Observational error","score":0.4738464951515198},{"id":"https://openalex.org/keywords/electricity-meter","display_name":"Electricity meter","score":0.4518314599990845},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44744402170181274},{"id":"https://openalex.org/keywords/system-identification","display_name":"System identification","score":0.4178858995437622},{"id":"https://openalex.org/keywords/data-modeling","display_name":"Data modeling","score":0.3697356879711151},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2739221155643463},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14217239618301392},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12546402215957642},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.08897694945335388}],"concepts":[{"id":"https://openalex.org/C42536954","wikidata":"https://www.wikidata.org/wiki/Q7049462","display_name":"Nonlinear autoregressive exogenous model","level":3,"score":0.914946436882019},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.719832718372345},{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.6299631595611572},{"id":"https://openalex.org/C159877910","wikidata":"https://www.wikidata.org/wiki/Q2202883","display_name":"Autoregressive model","level":2,"score":0.5936384797096252},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5803629755973816},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5774564743041992},{"id":"https://openalex.org/C24574437","wikidata":"https://www.wikidata.org/wiki/Q7135228","display_name":"Parametric model","level":3,"score":0.544126570224762},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5153433680534363},{"id":"https://openalex.org/C117251300","wikidata":"https://www.wikidata.org/wiki/Q1849855","display_name":"Parametric statistics","level":2,"score":0.5116482377052307},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.4738464951515198},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.4518314599990845},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44744402170181274},{"id":"https://openalex.org/C119247159","wikidata":"https://www.wikidata.org/wiki/Q1366192","display_name":"System identification","level":3,"score":0.4178858995437622},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.3697356879711151},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2739221155643463},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14217239618301392},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12546402215957642},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.08897694945335388},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2016.7520339","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2016.7520339","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1551463357","https://openalex.org/W2040135606","https://openalex.org/W2094268130","https://openalex.org/W2100559478","https://openalex.org/W2119943607","https://openalex.org/W2122078810","https://openalex.org/W2132465815","https://openalex.org/W2146323672","https://openalex.org/W2985336543","https://openalex.org/W6679718684"],"related_works":["https://openalex.org/W2606910468","https://openalex.org/W2734185189","https://openalex.org/W2359630406","https://openalex.org/W2289935687","https://openalex.org/W2914461365","https://openalex.org/W2034434590","https://openalex.org/W2382973115","https://openalex.org/W2353890496","https://openalex.org/W4379377656","https://openalex.org/W4385482789"],"abstract_inverted_index":{"The":[0,27,43,57,80],"paper":[1],"presents":[2],"a":[3,101,138],"methodology":[4],"to":[5,49,70,92],"model":[6,107],"the":[7,11,51,68,71,94,127],"nonlinearity":[8],"associated":[9],"with":[10,22],"error":[12,69,115],"in":[13,104],"measurement":[14],"of":[15,53,67,89,117,130,150],"energy":[16,118,131,151],"metering":[17,119],"system":[18,44,72,120],"using":[19],"nonlinear":[20,54,75,106],"autoregressive":[21],"exogenous":[23],"input":[24],"(NARX)":[25],"model.":[26],"experimental":[28,85],"results":[29],"are":[30],"obtained":[31],"for":[32,84,112,133,147],"active":[33],"and":[34,40,73,86,141],"reactive":[35],"power":[36,123],"under":[37,121],"both":[38],"sinusoidal":[39],"non-sinusoidal":[41],"conditions.":[42],"identification":[45],"technique":[46],"is":[47,61,64,77,82],"presented":[48],"understand":[50],"basics":[52],"modeling":[55,76,96],"structures.":[56],"prevalent":[58],"operating":[59],"condition":[60],"identified":[62],"which":[63,108],"contributing":[65],"most":[66],"its":[74],"carried":[78],"out.":[79],"comparison":[81],"performed":[83],"simulated":[87],"output":[88],"different":[90,122,134],"models,":[91],"decide":[93],"best":[95],"structure.":[97],"This":[98],"method":[99],"plays":[100],"vital":[102],"role":[103],"determining":[105],"reflects":[109],"high":[110],"fidelity":[111],"continuously":[113],"varying":[114],"pattern":[116,129],"quality":[124],"phenomenon.":[125],"Thus,":[126],"behavioral":[128],"meter":[132],"parametric":[135],"variations":[136],"becomes":[137],"prior":[139],"available":[140],"this":[142],"information":[143],"can":[144],"be":[145],"utilized":[146],"enhanced":[148],"performance":[149],"meter.":[152]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":4},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
