{"id":"https://openalex.org/W1599538695","doi":"https://doi.org/10.1109/i2mtc.2015.7151525","title":"Smart transducer interfaces applied to health monitoring","display_name":"Smart transducer interfaces applied to health monitoring","publication_year":2015,"publication_date":"2015-05-01","ids":{"openalex":"https://openalex.org/W1599538695","doi":"https://doi.org/10.1109/i2mtc.2015.7151525","mag":"1599538695"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2015.7151525","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2015.7151525","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017897629","display_name":"V\u00edtor V\u00edegas","orcid":"https://orcid.org/0000-0002-8929-1574"},"institutions":[{"id":"https://openalex.org/I4210102653","display_name":"Instituto Politecnico de Setubal","ror":"https://ror.org/01bvjz807","country_code":"PT","type":"education","lineage":["https://openalex.org/I4210102653"]},{"id":"https://openalex.org/I4210120471","display_name":"Instituto de Telecomunica\u00e7\u00f5es","ror":"https://ror.org/02ht4fk33","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210120471"]}],"countries":["PT"],"is_corresponding":true,"raw_author_name":"Vitor Viegas","raw_affiliation_strings":["Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","Polytechnic Institute of Set\u00fabal, Set\u00fabal, Portugal"],"affiliations":[{"raw_affiliation_string":"Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","institution_ids":["https://openalex.org/I4210120471"]},{"raw_affiliation_string":"Polytechnic Institute of Set\u00fabal, Set\u00fabal, Portugal","institution_ids":["https://openalex.org/I4210102653"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033037720","display_name":"J. M. Dias Pereira","orcid":"https://orcid.org/0000-0002-0183-132X"},"institutions":[{"id":"https://openalex.org/I4210102653","display_name":"Instituto Politecnico de Setubal","ror":"https://ror.org/01bvjz807","country_code":"PT","type":"education","lineage":["https://openalex.org/I4210102653"]},{"id":"https://openalex.org/I4210120471","display_name":"Instituto de Telecomunica\u00e7\u00f5es","ror":"https://ror.org/02ht4fk33","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210120471"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"J. M. Dias Pereira","raw_affiliation_strings":["Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","Polytechnic Institute of Set\u00fabal, Set\u00fabal, Portugal"],"affiliations":[{"raw_affiliation_string":"Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","institution_ids":["https://openalex.org/I4210120471"]},{"raw_affiliation_string":"Polytechnic Institute of Set\u00fabal, Set\u00fabal, Portugal","institution_ids":["https://openalex.org/I4210102653"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035367328","display_name":"Pedro Silva Gir\u00e3o","orcid":"https://orcid.org/0000-0002-3499-5320"},"institutions":[{"id":"https://openalex.org/I4210120471","display_name":"Instituto de Telecomunica\u00e7\u00f5es","ror":"https://ror.org/02ht4fk33","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210120471"]},{"id":"https://openalex.org/I4387152517","display_name":"Instituto Superior T\u00e9cnico","ror":"https://ror.org/03db2by73","country_code":null,"type":"education","lineage":["https://openalex.org/I141596103","https://openalex.org/I4387152517"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"Pedro Silva Girao","raw_affiliation_strings":["DEEC/Instituto Spoerior T\u00e9cnico, Lisbon, Portugal","Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal"],"affiliations":[{"raw_affiliation_string":"DEEC/Instituto Spoerior T\u00e9cnico, Lisbon, Portugal","institution_ids":["https://openalex.org/I4387152517"]},{"raw_affiliation_string":"Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","institution_ids":["https://openalex.org/I4210120471"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055315506","display_name":"Gabriela Postolache","orcid":"https://orcid.org/0000-0002-3052-1232"},"institutions":[{"id":"https://openalex.org/I4392738257","display_name":"Instituto de Medicina Molecular Jo\u00e3o Lobo Antunes","ror":"https://ror.org/019g8w217","country_code":null,"type":"facility","lineage":["https://openalex.org/I141596103","https://openalex.org/I4392738257"]},{"id":"https://openalex.org/I134168995","display_name":"National Legal Medicine Institute","ror":"https://ror.org/04zc40243","country_code":"PT","type":"government","lineage":["https://openalex.org/I134168995"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"Gabriela Postolache","raw_affiliation_strings":["Instituto de Medicina Molecular, Lisbon, Portugal"],"affiliations":[{"raw_affiliation_string":"Instituto de Medicina Molecular, Lisbon, Portugal","institution_ids":["https://openalex.org/I134168995","https://openalex.org/I4392738257"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5075764191","display_name":"Octavian Postolache","orcid":"https://orcid.org/0000-0001-5055-6347"},"institutions":[{"id":"https://openalex.org/I4210120471","display_name":"Instituto de Telecomunica\u00e7\u00f5es","ror":"https://ror.org/02ht4fk33","country_code":"PT","type":"nonprofit","lineage":["https://openalex.org/I4210120471"]},{"id":"https://openalex.org/I110026055","display_name":"Iscte \u2013 Instituto Universit\u00e1rio de Lisboa","ror":"https://ror.org/014837179","country_code":"PT","type":"education","lineage":["https://openalex.org/I110026055"]}],"countries":["PT"],"is_corresponding":false,"raw_author_name":"Octavian Postolache","raw_affiliation_strings":["ISCTE-IUL, Lisbon, Portugal","Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal"],"affiliations":[{"raw_affiliation_string":"ISCTE-IUL, Lisbon, Portugal","institution_ids":["https://openalex.org/I110026055"]},{"raw_affiliation_string":"Instituto de Telecomunica\u00e7\u00f5es, Lisbon, Portugal","institution_ids":["https://openalex.org/I4210120471"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5017897629"],"corresponding_institution_ids":["https://openalex.org/I4210102653","https://openalex.org/I4210120471"],"apc_list":null,"apc_paid":null,"fwci":0.3328,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.63318481,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"1","issue":null,"first_page":"1640","last_page":"1645"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.9805999994277954,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T13690","display_name":"Quality and Safety in Healthcare","score":0.9779999852180481,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.7774248123168945},{"id":"https://openalex.org/keywords/wheelchair","display_name":"Wheelchair","score":0.7429617047309875},{"id":"https://openalex.org/keywords/smart-transducer","display_name":"Smart transducer","score":0.7141750454902649},{"id":"https://openalex.org/keywords/personalization","display_name":"Personalization","score":0.6737985610961914},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6307593584060669},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.5195658206939697},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.37309524416923523},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.33546650409698486},{"id":"https://openalex.org/keywords/human\u2013computer-interaction","display_name":"Human\u2013computer interaction","score":0.33060184121131897},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2707059383392334},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1962507665157318}],"concepts":[{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7774248123168945},{"id":"https://openalex.org/C2781042323","wikidata":"https://www.wikidata.org/wiki/Q191931","display_name":"Wheelchair","level":2,"score":0.7429617047309875},{"id":"https://openalex.org/C135984084","wikidata":"https://www.wikidata.org/wiki/Q7544087","display_name":"Smart transducer","level":3,"score":0.7141750454902649},{"id":"https://openalex.org/C183003079","wikidata":"https://www.wikidata.org/wiki/Q1000371","display_name":"Personalization","level":2,"score":0.6737985610961914},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6307593584060669},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.5195658206939697},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.37309524416923523},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.33546650409698486},{"id":"https://openalex.org/C107457646","wikidata":"https://www.wikidata.org/wiki/Q207434","display_name":"Human\u2013computer interaction","level":1,"score":0.33060184121131897},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2707059383392334},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1962507665157318},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2015.7151525","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2015.7151525","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W80302449","https://openalex.org/W141599801","https://openalex.org/W622865100","https://openalex.org/W2019885331","https://openalex.org/W2020842728","https://openalex.org/W2069227013","https://openalex.org/W2117451748","https://openalex.org/W2126041106","https://openalex.org/W2165456500","https://openalex.org/W6603245587","https://openalex.org/W6605679245","https://openalex.org/W6619762582"],"related_works":["https://openalex.org/W2350888815","https://openalex.org/W4206782192","https://openalex.org/W1964331107","https://openalex.org/W4233253194","https://openalex.org/W2164153644","https://openalex.org/W2164675997","https://openalex.org/W268256","https://openalex.org/W2386769919","https://openalex.org/W2003995732","https://openalex.org/W2054612865"],"abstract_inverted_index":{"The":[0,16],"paper":[1],"presents":[2],"a":[3,58,68],"smart":[4,21,69],"sensing":[5,85],"system":[6,17,107],"for":[7],"health":[8],"monitoring":[9],"based":[10],"on":[11],"the":[12,25,38,41,46,50,55,63,74,84,90,94,103,106],"IEEE":[13],"1451":[14],"standard.":[15],"makes":[18],"use":[19],"of":[20,40,57,67,93,105],"transducer":[22,31],"interfaces,":[23],"namely":[24],"1451.1":[26,42],"information":[27,43],"model":[28,44],"and":[29,87,99,108],"1451.4":[30],"data":[32],"sheets.":[33],"Attention":[34],"is":[35],"given":[36],"to":[37,53,72,82,88],"implementation":[39],"using":[45],".NET":[47],"Framework,":[48],"including":[49],"customization":[51],"efforts":[52],"meet":[54],"requirements":[56],"specific":[59],"application,":[60],"which,":[61],"in":[62],"present":[64],"case,":[65],"consists":[66],"wheelchair":[70],"prepared":[71],"monitor":[73],"user's":[75],"physical":[76],"condition.":[77],"Experimental":[78],"tests":[79],"were":[80],"done":[81],"characterize":[83],"channels":[86],"evaluate":[89],"communication":[91],"capabilities":[92],"system.":[95],"Results":[96],"are":[97],"analyzed":[98],"conclusions":[100],"extracted":[101],"about":[102],"effectiveness":[104],"its":[109],"overall":[110],"performance.":[111]},"counts_by_year":[{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
