{"id":"https://openalex.org/W2092986561","doi":"https://doi.org/10.1109/i2mtc.2014.6860765","title":"Effects of stray capacitances on high voltage current transformers","display_name":"Effects of stray capacitances on high voltage current transformers","publication_year":2014,"publication_date":"2014-05-01","ids":{"openalex":"https://openalex.org/W2092986561","doi":"https://doi.org/10.1109/i2mtc.2014.6860765","mag":"2092986561"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2014.6860765","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860765","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5030391429","display_name":"Gonzalo Aristoy","orcid":null},"institutions":[{"id":"https://openalex.org/I4210117719","display_name":"National Administration of Power Plants and Electrical Transmissions (Uruguay)","ror":"https://ror.org/02wc3s860","country_code":"UY","type":"company","lineage":["https://openalex.org/I4210117719"]}],"countries":["UY"],"is_corresponding":true,"raw_author_name":"Gonzalo Aristoy","raw_affiliation_strings":["UTE, Laboratory, Montevideo, Uruguay","Lab., UTE, Montevideo, Uruguay"],"affiliations":[{"raw_affiliation_string":"UTE, Laboratory, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]},{"raw_affiliation_string":"Lab., UTE, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083293179","display_name":"Alejandro Santos","orcid":"https://orcid.org/0000-0002-6100-6102"},"institutions":[{"id":"https://openalex.org/I4210117719","display_name":"National Administration of Power Plants and Electrical Transmissions (Uruguay)","ror":"https://ror.org/02wc3s860","country_code":"UY","type":"company","lineage":["https://openalex.org/I4210117719"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Alejandro Santos","raw_affiliation_strings":["UTE, Laboratory, Montevideo, Uruguay","Lab., UTE, Montevideo, Uruguay"],"affiliations":[{"raw_affiliation_string":"UTE, Laboratory, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]},{"raw_affiliation_string":"Lab., UTE, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5041569136","display_name":"Daniel Slomovitz","orcid":"https://orcid.org/0000-0003-0909-6443"},"institutions":[{"id":"https://openalex.org/I4210117719","display_name":"National Administration of Power Plants and Electrical Transmissions (Uruguay)","ror":"https://ror.org/02wc3s860","country_code":"UY","type":"company","lineage":["https://openalex.org/I4210117719"]}],"countries":["UY"],"is_corresponding":false,"raw_author_name":"Daniel Slomovitz","raw_affiliation_strings":["UTE, Laboratory, Montevideo, Uruguay","Lab., UTE, Montevideo, Uruguay"],"affiliations":[{"raw_affiliation_string":"UTE, Laboratory, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]},{"raw_affiliation_string":"Lab., UTE, Montevideo, Uruguay","institution_ids":["https://openalex.org/I4210117719"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5030391429"],"corresponding_institution_ids":["https://openalex.org/I4210117719"],"apc_list":null,"apc_paid":null,"fwci":0.4187,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.69144597,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"81","issue":null,"first_page":"348","last_page":"351"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.7190552353858948},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.6430357694625854},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.639214277267456},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6175934672355652},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.5779213309288025},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.539185106754303},{"id":"https://openalex.org/keywords/autotransformer","display_name":"Autotransformer","score":0.5290896892547607},{"id":"https://openalex.org/keywords/parasitic-capacitance","display_name":"Parasitic capacitance","score":0.5063456296920776},{"id":"https://openalex.org/keywords/high-voltage","display_name":"High voltage","score":0.45142263174057007},{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.44246169924736023},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4113544821739197},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.39069876074790955},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.38640478253364563},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2648141384124756}],"concepts":[{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.7190552353858948},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6430357694625854},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.639214277267456},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6175934672355652},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.5779213309288025},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.539185106754303},{"id":"https://openalex.org/C22958824","wikidata":"https://www.wikidata.org/wiki/Q565668","display_name":"Autotransformer","level":5,"score":0.5290896892547607},{"id":"https://openalex.org/C154318817","wikidata":"https://www.wikidata.org/wiki/Q2157249","display_name":"Parasitic capacitance","level":4,"score":0.5063456296920776},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.45142263174057007},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.44246169924736023},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4113544821739197},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.39069876074790955},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.38640478253364563},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2648141384124756},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/i2mtc.2014.6860765","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860765","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.6000000238418579,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2024311804","https://openalex.org/W2133782211","https://openalex.org/W6656529630"],"related_works":["https://openalex.org/W2387494271","https://openalex.org/W2546559749","https://openalex.org/W2376540661","https://openalex.org/W2392597137","https://openalex.org/W4232850969","https://openalex.org/W2991413088","https://openalex.org/W3086766444","https://openalex.org/W4251988900","https://openalex.org/W2358439892","https://openalex.org/W2184549857"],"abstract_inverted_index":{"This":[0],"paper":[1],"evaluates":[2],"the":[3,28,37,68],"effect":[4],"of":[5,47,59,81],"stray":[6],"capacitances":[7],"between":[8,50],"primary":[9,38],"and":[10,75],"secondary":[11],"windings":[12,26],"on":[13,78],"current":[14,48],"transformers":[15,82],"(CT)":[16],"used":[17],"in":[18,35],"high":[19,42],"voltage":[20,43,73],"networks.":[21],"Ground":[22],"potential":[23],"at":[24,41],"all":[25],"is":[27,40,54],"typical":[29],"configuration":[30],"during":[31],"laboratory":[32],"calibration.":[33],"However,":[34],"service,":[36],"winding":[39],"potential.":[44],"The":[45],"variation":[46],"errors":[49,70],"both":[51],"working":[52],"conditions":[53],"evaluated":[55],"for":[56],"a":[57],"set":[58],"CTs.":[60],"A":[61],"calibration":[62],"system":[63],"was":[64],"developed":[65],"that":[66],"measures":[67],"transformer":[69],"under":[71],"nominal":[72],"operation,":[74],"experimental":[76],"results":[77],"different":[79],"type":[80],"are":[83],"presented.":[84]},"counts_by_year":[{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2015,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}