{"id":"https://openalex.org/W2068732868","doi":"https://doi.org/10.1109/i2mtc.2014.6860744","title":"Improving availability of distributed PMU in electrical substations using wireless redundant process bus","display_name":"Improving availability of distributed PMU in electrical substations using wireless redundant process bus","publication_year":2014,"publication_date":"2014-05-01","ids":{"openalex":"https://openalex.org/W2068732868","doi":"https://doi.org/10.1109/i2mtc.2014.6860744","mag":"2068732868"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2014.6860744","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860744","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5057770797","display_name":"Paolo Castello","orcid":"https://orcid.org/0000-0002-8767-6243"},"institutions":[{"id":"https://openalex.org/I172446870","display_name":"University of Cagliari","ror":"https://ror.org/003109y17","country_code":"IT","type":"education","lineage":["https://openalex.org/I172446870"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Castello","raw_affiliation_strings":["Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","institution_ids":["https://openalex.org/I172446870"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy","institution_ids":["https://openalex.org/I172446870"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017887033","display_name":"Paolo Ferrari","orcid":"https://orcid.org/0000-0002-6349-4410"},"institutions":[{"id":"https://openalex.org/I79940851","display_name":"University of Brescia","ror":"https://ror.org/02q2d2610","country_code":"IT","type":"education","lineage":["https://openalex.org/I79940851"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Ferrari","raw_affiliation_strings":["Universita degli Studi di Brescia, Brescia, Lombardia, IT","Department of Information Engineering, University of Brescia Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Brescia, Brescia, Lombardia, IT","institution_ids":["https://openalex.org/I79940851"]},{"raw_affiliation_string":"Department of Information Engineering, University of Brescia Brescia, Italy","institution_ids":["https://openalex.org/I79940851"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5087795637","display_name":"Alessandra Flammini","orcid":"https://orcid.org/0000-0002-2046-0720"},"institutions":[{"id":"https://openalex.org/I79940851","display_name":"University of Brescia","ror":"https://ror.org/02q2d2610","country_code":"IT","type":"education","lineage":["https://openalex.org/I79940851"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Alessandra Flammini","raw_affiliation_strings":["Universita degli Studi di Brescia, Brescia, Lombardia, IT","Department of Information Engineering, University of Brescia Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Brescia, Brescia, Lombardia, IT","institution_ids":["https://openalex.org/I79940851"]},{"raw_affiliation_string":"Department of Information Engineering, University of Brescia Brescia, Italy","institution_ids":["https://openalex.org/I79940851"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091218170","display_name":"Carlo Muscas","orcid":"https://orcid.org/0000-0003-0553-5875"},"institutions":[{"id":"https://openalex.org/I172446870","display_name":"University of Cagliari","ror":"https://ror.org/003109y17","country_code":"IT","type":"education","lineage":["https://openalex.org/I172446870"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Carlo Muscas","raw_affiliation_strings":["Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","institution_ids":["https://openalex.org/I172446870"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy","institution_ids":["https://openalex.org/I172446870"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030510243","display_name":"Paolo Attilio Pegoraro","orcid":"https://orcid.org/0000-0003-4501-1195"},"institutions":[{"id":"https://openalex.org/I172446870","display_name":"University of Cagliari","ror":"https://ror.org/003109y17","country_code":"IT","type":"education","lineage":["https://openalex.org/I172446870"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Attilio Pegoraro","raw_affiliation_strings":["Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Cagliari, Cagliari, Sardegna, IT","institution_ids":["https://openalex.org/I172446870"]},{"raw_affiliation_string":"Dept. of Electr. & Electron. Eng., Univ. of Cagliari, Cagliari, , Italy","institution_ids":["https://openalex.org/I172446870"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007335960","display_name":"Stefano Rinaldi","orcid":"https://orcid.org/0000-0001-7300-1053"},"institutions":[{"id":"https://openalex.org/I79940851","display_name":"University of Brescia","ror":"https://ror.org/02q2d2610","country_code":"IT","type":"education","lineage":["https://openalex.org/I79940851"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Stefano Rinaldi","raw_affiliation_strings":["Universita degli Studi di Brescia, Brescia, Lombardia, IT","Department of Information Engineering, University of Brescia Brescia, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Brescia, Brescia, Lombardia, IT","institution_ids":["https://openalex.org/I79940851"]},{"raw_affiliation_string":"Department of Information Engineering, University of Brescia Brescia, Italy","institution_ids":["https://openalex.org/I79940851"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"239","last_page":"244"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12216","display_name":"Network Time Synchronization Technologies","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12146","display_name":"Power Line Communications and Noise","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backup","display_name":"Backup","score":0.7449418306350708},{"id":"https://openalex.org/keywords/phasor-measurement-unit","display_name":"Phasor measurement unit","score":0.6266010999679565},{"id":"https://openalex.org/keywords/iec-61850","display_name":"IEC 61850","score":0.5736732482910156},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.566788375377655},{"id":"https://openalex.org/keywords/data-synchronization","display_name":"Data synchronization","score":0.5387613773345947},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.5285574197769165},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.4844262897968292},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.48251649737358093},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4778989553451538},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.4730735719203949},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.43969494104385376},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4210495948791504},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.3592469096183777},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.359078586101532},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.3571772575378418},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31696444749832153},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.1642358899116516},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.10912197828292847},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.09714043140411377}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.7449418306350708},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.6266010999679565},{"id":"https://openalex.org/C2778907243","wikidata":"https://www.wikidata.org/wiki/Q168160","display_name":"IEC 61850","level":3,"score":0.5736732482910156},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.566788375377655},{"id":"https://openalex.org/C108734733","wikidata":"https://www.wikidata.org/wiki/Q1172333","display_name":"Data synchronization","level":3,"score":0.5387613773345947},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.5285574197769165},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.4844262897968292},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.48251649737358093},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4778989553451538},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.4730735719203949},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.43969494104385376},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4210495948791504},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.3592469096183777},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.359078586101532},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.3571772575378418},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31696444749832153},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.1642358899116516},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.10912197828292847},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.09714043140411377},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/i2mtc.2014.6860744","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860744","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.unibs.it:11379/317309","is_oa":false,"landing_page_url":"http://hdl.handle.net/11379/317309","pdf_url":null,"source":{"id":"https://openalex.org/S4306400804","display_name":"Institutional Research Information System (Universit\u00e0 degli Studi di Brescia)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I66752286","host_organization_name":"University of Milano-Bicocca","host_organization_lineage":["https://openalex.org/I66752286"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:iris.unica.it:11584/109834","is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6860999&isnumber=6860504","pdf_url":null,"source":{"id":"https://openalex.org/S4377196293","display_name":"UNICA IRIS Institutional Research Information System (University of Cagliari)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I172446870","host_organization_name":"University of Cagliari","host_organization_lineage":["https://openalex.org/I172446870"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferencePaper"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6200000047683716,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1500869549","https://openalex.org/W2043169850","https://openalex.org/W2044938589","https://openalex.org/W2053853038","https://openalex.org/W2058254697","https://openalex.org/W2061738154","https://openalex.org/W2062988366","https://openalex.org/W2098158437","https://openalex.org/W2103507343","https://openalex.org/W2121098361","https://openalex.org/W2164182784","https://openalex.org/W2171176312","https://openalex.org/W2359068152"],"related_works":["https://openalex.org/W2060186004","https://openalex.org/W2564500233","https://openalex.org/W2337841097","https://openalex.org/W2028471916","https://openalex.org/W1538400183","https://openalex.org/W2027377403","https://openalex.org/W2766771072","https://openalex.org/W2096980798","https://openalex.org/W2547260311","https://openalex.org/W2154842468"],"abstract_inverted_index":{"Protection":[0],"and":[1,23,37,99],"measurement":[2,57,104],"systems":[3],"in":[4,48],"electrical":[5],"substations":[6],"are":[7,107],"requested":[8],"to":[9,41,70],"have":[10],"high":[11],"availability.":[12],"When":[13],"considering":[14],"an":[15,80],"all-digital":[16],"substation":[17],"protection":[18],"system,":[19],"all":[20],"the":[21,42,51,61],"components":[22],"infrastructure":[24],"devices":[25],"(instrument":[26],"transformers,":[27],"processing":[28],"units,":[29,31],"merging":[30],"intelligent":[32],"electronic":[33],"devices,":[34],"communication":[35],"network":[36,84,112],"synchronization":[38,97],"source)":[39],"contribute":[40],"overall":[43],"availability":[44,52],"level.":[45],"In":[46],"particular,":[47],"this":[49],"paper":[50],"of":[53,77],"a":[54,91,110],"distributed":[55,72],"phasor":[56],"unit":[58],"inspired":[59],"by":[60,75],"standards":[62],"IEC":[63],"61850,":[64],"is":[65,85],"investigated.":[66],"A":[67],"cost-effective":[68],"solution":[69],"enhance":[71],"PMU":[73],"reliability":[74],"means":[76],"redundancy":[78],"using":[79],"IEEE":[81],"802.11":[82],"wireless":[83,92,111],"proposed.":[86],"The":[87],"process":[88],"bus":[89],"has":[90],"backup":[93],"for":[94,109,118],"both":[95],"time":[96],"protocol":[98],"sampled":[100],"values":[101],"packets":[102],"carrying":[103],"information.":[105],"Results":[106],"reported":[108],"that":[113],"uses":[114],"software":[115],"based":[116],"timestamping":[117],"PTP":[119],"synchronization.":[120]},"counts_by_year":[{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2016-06-24T00:00:00"}
