{"id":"https://openalex.org/W2028616016","doi":"https://doi.org/10.1109/i2mtc.2014.6860735","title":"Low cost measurement equipment for the accurate calibration of voltage and current transducers","display_name":"Low cost measurement equipment for the accurate calibration of voltage and current transducers","publication_year":2014,"publication_date":"2014-05-01","ids":{"openalex":"https://openalex.org/W2028616016","doi":"https://doi.org/10.1109/i2mtc.2014.6860735","mag":"2028616016"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2014.6860735","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860735","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5024711198","display_name":"G. Crotti","orcid":"https://orcid.org/0000-0001-7563-396X"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Gabriella Crotti","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Torino, Piemonte, IT","INRIM, Turin, Italy"],"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Torino, Piemonte, IT","institution_ids":["https://openalex.org/I4210136559"]},{"raw_affiliation_string":"INRIM, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090407044","display_name":"Daniele Gallo","orcid":"https://orcid.org/0000-0002-1553-7498"},"institutions":[{"id":"https://openalex.org/I4210129624","display_name":"Azienda Ospedaliera Universitaria Universit\u00e0 degli Studi della Campania Luigi Vanvitelli","ror":"https://ror.org/02p9ey581","country_code":"IT","type":"healthcare","lineage":["https://openalex.org/I4210129624"]},{"id":"https://openalex.org/I197809005","display_name":"University of Campania \"Luigi Vanvitelli\"","ror":"https://ror.org/02kqnpp86","country_code":"IT","type":"education","lineage":["https://openalex.org/I197809005"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Daniele Gallo","raw_affiliation_strings":["Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy"],"affiliations":[{"raw_affiliation_string":"Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","institution_ids":["https://openalex.org/I4210129624"]},{"raw_affiliation_string":"Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy","institution_ids":["https://openalex.org/I197809005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045083630","display_name":"Domenico Giordano","orcid":"https://orcid.org/0000-0002-2616-9459"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Domenico Giordano","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Torino, Piemonte, IT","INRIM, Turin, Italy"],"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Torino, Piemonte, IT","institution_ids":["https://openalex.org/I4210136559"]},{"raw_affiliation_string":"INRIM, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5058303973","display_name":"Carmine Landi","orcid":"https://orcid.org/0000-0003-0922-883X"},"institutions":[{"id":"https://openalex.org/I197809005","display_name":"University of Campania \"Luigi Vanvitelli\"","ror":"https://ror.org/02kqnpp86","country_code":"IT","type":"education","lineage":["https://openalex.org/I197809005"]},{"id":"https://openalex.org/I4210129624","display_name":"Azienda Ospedaliera Universitaria Universit\u00e0 degli Studi della Campania Luigi Vanvitelli","ror":"https://ror.org/02p9ey581","country_code":"IT","type":"healthcare","lineage":["https://openalex.org/I4210129624"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Carmine Landi","raw_affiliation_strings":["Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy"],"affiliations":[{"raw_affiliation_string":"Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","institution_ids":["https://openalex.org/I4210129624"]},{"raw_affiliation_string":"Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy","institution_ids":["https://openalex.org/I197809005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011115933","display_name":"Mario Luiso","orcid":"https://orcid.org/0000-0003-1311-9791"},"institutions":[{"id":"https://openalex.org/I197809005","display_name":"University of Campania \"Luigi Vanvitelli\"","ror":"https://ror.org/02kqnpp86","country_code":"IT","type":"education","lineage":["https://openalex.org/I197809005"]},{"id":"https://openalex.org/I4210129624","display_name":"Azienda Ospedaliera Universitaria Universit\u00e0 degli Studi della Campania Luigi Vanvitelli","ror":"https://ror.org/02p9ey581","country_code":"IT","type":"healthcare","lineage":["https://openalex.org/I4210129624"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Mario Luiso","raw_affiliation_strings":["Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy"],"affiliations":[{"raw_affiliation_string":"Universita degli Studi della Campania Luigi Vanvitelli, Napoli, Campania, IT","institution_ids":["https://openalex.org/I4210129624"]},{"raw_affiliation_string":"Dept. of Ind. & Inf. Eng., Second Univ. of Naples, Aversa, , Italy","institution_ids":["https://openalex.org/I197809005"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066001654","display_name":"Claudio Cherbaucich","orcid":null},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Claudio Cherbaucich","raw_affiliation_strings":["T&D Technologies Department - Ricerca sul Sistema Energetico - RSE S.p.A., Milano, Italy","T&D Technol. Dept., Ricerca sul Sistema Energetico - RSE S.p.A., Milan, Italy"],"affiliations":[{"raw_affiliation_string":"T&D Technologies Department - Ricerca sul Sistema Energetico - RSE S.p.A., Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]},{"raw_affiliation_string":"T&D Technol. Dept., Ricerca sul Sistema Energetico - RSE S.p.A., Milan, Italy","institution_ids":["https://openalex.org/I4210134634"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013511150","display_name":"Paolo Mazza","orcid":"https://orcid.org/0000-0002-9870-9573"},"institutions":[{"id":"https://openalex.org/I4210134634","display_name":"Ricerca sul Sistema Energetico (Italy)","ror":"https://ror.org/03n6cf849","country_code":"IT","type":"company","lineage":["https://openalex.org/I4210134634"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Paolo Mazza","raw_affiliation_strings":["T&D Technologies Department - Ricerca sul Sistema Energetico - RSE S.p.A., Milano, Italy","T&D Technol. Dept., Ricerca sul Sistema Energetico - RSE S.p.A., Milan, Italy"],"affiliations":[{"raw_affiliation_string":"T&D Technologies Department - Ricerca sul Sistema Energetico - RSE S.p.A., Milano, Italy","institution_ids":["https://openalex.org/I4210134634"]},{"raw_affiliation_string":"T&D Technol. Dept., Ricerca sul Sistema Energetico - RSE S.p.A., Milan, Italy","institution_ids":["https://openalex.org/I4210134634"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5024711198"],"corresponding_institution_ids":["https://openalex.org/I4210136559"],"apc_list":null,"apc_paid":null,"fwci":1.7021,"has_fulltext":false,"cited_by_count":22,"citation_normalized_percentile":{"value":0.86124147,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"83","issue":null,"first_page":"202","last_page":"206"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.6698194742202759},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.6671804785728455},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6631861925125122},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6574037671089172},{"id":"https://openalex.org/keywords/data-acquisition","display_name":"Data acquisition","score":0.6305651664733887},{"id":"https://openalex.org/keywords/system-of-measurement","display_name":"System of measurement","score":0.5930646061897278},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5413503646850586},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5225279331207275},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5057494640350342},{"id":"https://openalex.org/keywords/multimeter","display_name":"Multimeter","score":0.5001943111419678},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49560606479644775},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.460789293050766},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33812132477760315},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0977334976196289}],"concepts":[{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.6698194742202759},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.6671804785728455},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6631861925125122},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6574037671089172},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.6305651664733887},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.5930646061897278},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5413503646850586},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5225279331207275},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5057494640350342},{"id":"https://openalex.org/C103185065","wikidata":"https://www.wikidata.org/wiki/Q189996","display_name":"Multimeter","level":3,"score":0.5001943111419678},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49560606479644775},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.460789293050766},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33812132477760315},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0977334976196289},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/i2mtc.2014.6860735","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2014.6860735","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings","raw_type":"proceedings-article"},{"id":"pmh:oai:iris.inrim.it:11696/34050","is_oa":false,"landing_page_url":"http://hdl.handle.net/11696/34050","pdf_url":null,"source":{"id":"https://openalex.org/S4306400708","display_name":"CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I27837315","host_organization_name":"University of Michigan","host_organization_lineage":["https://openalex.org/I27837315"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.7900000214576721}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":9,"referenced_works":["https://openalex.org/W1972996076","https://openalex.org/W1980267422","https://openalex.org/W2014200457","https://openalex.org/W2021690945","https://openalex.org/W2033760108","https://openalex.org/W2047211402","https://openalex.org/W2156002823","https://openalex.org/W2160647678","https://openalex.org/W2325766105"],"related_works":["https://openalex.org/W2375147236","https://openalex.org/W2366204932","https://openalex.org/W2387276603","https://openalex.org/W3206226854","https://openalex.org/W1011722972","https://openalex.org/W2032931220","https://openalex.org/W2113376802","https://openalex.org/W2366713371","https://openalex.org/W2362469905","https://openalex.org/W4313229716"],"abstract_inverted_index":{"The":[0,41,89],"increasing":[1],"interest":[2],"in":[3,6,15],"the":[4,16,28,48,96,112],"use":[5],"medium":[7],"and":[8,37,53,57,65,68,84,110,119],"high":[9],"voltage":[10,18,56,85],"networks":[11],"as":[12,14],"well":[13],"low":[17,22,54,63],"ones":[19],"of":[20,30,50,81,98,108,114,116,121],"non-conventional":[21],"power":[23,55],"instrument":[24],"measurement":[25,39,45,69],"transformers":[26],"entails":[27],"availability":[29],"dedicated":[31],"calibration":[32,49,97],"set-up,":[33],"equipped":[34],"with":[35,100],"flexible":[36],"accurate":[38],"systems.":[40],"paper":[42],"presents":[43],"a":[44,62,75],"system":[46,79,91],"for":[47,95],"both":[51],"inductive":[52],"current":[58,83],"transformers,":[59],"which":[60],"includes":[61],"cost":[64],"digital":[66],"acquisition":[67,78,87],"equipment.":[70],"It":[71],"is":[72],"based":[73],"on":[74],"portable":[76],"data":[77,86],"composed":[80],"various":[82],"boards.":[88],"proposed":[90],"can":[92],"be":[93],"used":[94],"transducers":[99],"analog":[101],"output":[102],"from":[103],"DC":[104],"up":[105],"to":[106],"tens":[107],"kilohertz":[109],"allows":[111],"comparison":[113],"signals":[115],"different":[117],"kind":[118],"order":[120],"magnitude.":[122]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":5},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":2}],"updated_date":"2026-03-20T23:20:44.827607","created_date":"2025-10-10T00:00:00"}
