{"id":"https://openalex.org/W2000163934","doi":"https://doi.org/10.1109/i2mtc.2013.6555503","title":"Safety analysis in oil &amp;amp; gas industry in compliance with standards IEC61508 and IEC61511: Methods and applications","display_name":"Safety analysis in oil &amp;amp; gas industry in compliance with standards IEC61508 and IEC61511: Methods and applications","publication_year":2013,"publication_date":"2013-05-01","ids":{"openalex":"https://openalex.org/W2000163934","doi":"https://doi.org/10.1109/i2mtc.2013.6555503","mag":"2000163934"},"language":"en","primary_location":{"id":"doi:10.1109/i2mtc.2013.6555503","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2013.6555503","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5107410257","display_name":"Marcantonio Catelani","orcid":"https://orcid.org/0000-0002-9537-9724"},"institutions":[{"id":"https://openalex.org/I45084792","display_name":"University of Florence","ror":"https://ror.org/04jr1s763","country_code":"IT","type":"education","lineage":["https://openalex.org/I45084792"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Marcantonio Catelani","raw_affiliation_strings":["Department of Information Engineering, University of Florence, Florence, Italy","Department of Information Engineering University of Florence, Florence, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Florence, Florence, Italy","institution_ids":["https://openalex.org/I45084792"]},{"raw_affiliation_string":"Department of Information Engineering University of Florence, Florence, Italy","institution_ids":["https://openalex.org/I45084792"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086840768","display_name":"Lorenzo Ciani","orcid":"https://orcid.org/0000-0001-7820-6656"},"institutions":[{"id":"https://openalex.org/I45084792","display_name":"University of Florence","ror":"https://ror.org/04jr1s763","country_code":"IT","type":"education","lineage":["https://openalex.org/I45084792"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Lorenzo Ciani","raw_affiliation_strings":["Department of Information Engineering, University of Florence, Florence, Italy","Department of Information Engineering University of Florence, Florence, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Florence, Florence, Italy","institution_ids":["https://openalex.org/I45084792"]},{"raw_affiliation_string":"Department of Information Engineering University of Florence, Florence, Italy","institution_ids":["https://openalex.org/I45084792"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026199235","display_name":"V. Luongo","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Valentina Luongo","raw_affiliation_strings":["Department ASE, EMST, System and Auxiliary Engineering, GE Oil &Gas Nuovo Pignone, Florence, Italy","Dept. ASE/EMST, GE OIL&GAS Nuovo Pignone, Florence, Italy"],"affiliations":[{"raw_affiliation_string":"Department ASE, EMST, System and Auxiliary Engineering, GE Oil &Gas Nuovo Pignone, Florence, Italy","institution_ids":[]},{"raw_affiliation_string":"Dept. ASE/EMST, GE OIL&GAS Nuovo Pignone, Florence, Italy","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5107410257"],"corresponding_institution_ids":["https://openalex.org/I45084792"],"apc_list":null,"apc_paid":null,"fwci":2.8647,"has_fulltext":false,"cited_by_count":26,"citation_normalized_percentile":{"value":0.91046378,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"686","last_page":"690"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},"topics":[{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11619","display_name":"Combustion and Detonation Processes","score":0.9769999980926514,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/functional-safety","display_name":"Functional safety","score":0.7082202434539795},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6078534722328186},{"id":"https://openalex.org/keywords/reliability-block-diagram","display_name":"Reliability block diagram","score":0.6047723293304443},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.5764511823654175},{"id":"https://openalex.org/keywords/system-safety","display_name":"System safety","score":0.5762678980827332},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5658477544784546},{"id":"https://openalex.org/keywords/safety-case","display_name":"Safety case","score":0.5096786022186279},{"id":"https://openalex.org/keywords/safety-engineering","display_name":"Safety engineering","score":0.5084608793258667},{"id":"https://openalex.org/keywords/safety-standards","display_name":"Safety standards","score":0.49008214473724365},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.4898209273815155},{"id":"https://openalex.org/keywords/safety-instrumented-system","display_name":"Safety instrumented system","score":0.4852137863636017},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.46734219789505005},{"id":"https://openalex.org/keywords/fault-tree-analysis","display_name":"Fault tree analysis","score":0.4576806426048279},{"id":"https://openalex.org/keywords/work","display_name":"Work (physics)","score":0.4331710934638977},{"id":"https://openalex.org/keywords/process-safety","display_name":"Process safety","score":0.42783182859420776},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4158553183078766},{"id":"https://openalex.org/keywords/work-in-process","display_name":"Work in process","score":0.2905126214027405},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.19372987747192383},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.14144495129585266},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.12270602583885193}],"concepts":[{"id":"https://openalex.org/C148493468","wikidata":"https://www.wikidata.org/wiki/Q2646951","display_name":"Functional safety","level":2,"score":0.7082202434539795},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6078534722328186},{"id":"https://openalex.org/C18074226","wikidata":"https://www.wikidata.org/wiki/Q7310986","display_name":"Reliability block diagram","level":3,"score":0.6047723293304443},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5764511823654175},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.5762678980827332},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5658477544784546},{"id":"https://openalex.org/C2780234205","wikidata":"https://www.wikidata.org/wiki/Q2281276","display_name":"Safety case","level":2,"score":0.5096786022186279},{"id":"https://openalex.org/C94279714","wikidata":"https://www.wikidata.org/wiki/Q6496962","display_name":"Safety engineering","level":2,"score":0.5084608793258667},{"id":"https://openalex.org/C2776179734","wikidata":"https://www.wikidata.org/wiki/Q7398668","display_name":"Safety standards","level":2,"score":0.49008214473724365},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4898209273815155},{"id":"https://openalex.org/C22607221","wikidata":"https://www.wikidata.org/wiki/Q825237","display_name":"Safety instrumented system","level":3,"score":0.4852137863636017},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.46734219789505005},{"id":"https://openalex.org/C107094494","wikidata":"https://www.wikidata.org/wiki/Q428453","display_name":"Fault tree analysis","level":2,"score":0.4576806426048279},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.4331710934638977},{"id":"https://openalex.org/C80038721","wikidata":"https://www.wikidata.org/wiki/Q4380673","display_name":"Process safety","level":3,"score":0.42783182859420776},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4158553183078766},{"id":"https://openalex.org/C174998907","wikidata":"https://www.wikidata.org/wiki/Q357662","display_name":"Work in process","level":2,"score":0.2905126214027405},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.19372987747192383},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.14144495129585266},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.12270602583885193},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/i2mtc.2013.6555503","is_oa":false,"landing_page_url":"https://doi.org/10.1109/i2mtc.2013.6555503","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","raw_type":"proceedings-article"},{"id":"pmh:oai:flore.unifi.it:2158/835307","is_oa":false,"landing_page_url":"http://hdl.handle.net/2158/835307","pdf_url":null,"source":{"id":"https://openalex.org/S4306402033","display_name":"Florence Research (University of Florence)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I45084792","host_organization_name":"University of Florence","host_organization_lineage":["https://openalex.org/I45084792"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4099999964237213,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1970852385","https://openalex.org/W1981345493","https://openalex.org/W2045284289","https://openalex.org/W2089609099","https://openalex.org/W2105086490","https://openalex.org/W2113742095","https://openalex.org/W2124473145","https://openalex.org/W4252102654"],"related_works":["https://openalex.org/W2105086490","https://openalex.org/W2298853443","https://openalex.org/W2747004715","https://openalex.org/W158173017","https://openalex.org/W1971912906","https://openalex.org/W2807832237","https://openalex.org/W2372478624","https://openalex.org/W1483005295","https://openalex.org/W2016459326","https://openalex.org/W2000163934"],"abstract_inverted_index":{"The":[0,30,71,204],"aim":[1],"of":[2,11,18,36,39,62,74,103,121,131,151,234],"Functional":[3,31,75],"Safety":[4,32,43,76,139,236],"(FS)":[5],"is":[6,33,191],"freedom":[7],"from":[8],"unacceptable":[9],"risk":[10],"physical":[12],"injury":[13],"or":[14,21,27],"damage":[15,24],"to":[16,25,28,55,108,169,207,210,213,223,249],"health":[17],"people":[19],"directly":[20],"indirectly":[22],"(through":[23],"property":[26],"environment).":[29],"the":[34,49,59,80,109,112,119,123,129,152,155,161,164,167,171,198,202,243],"part":[35],"overall":[37],"safety":[38],"a":[40,101,115,137,148,195,220,228],"system,":[41],"called":[42],"Instrumented":[44,140,237],"System":[45,141],"that":[46,98,242],"depends":[47],"on":[48,133,166,178],"system":[50],"operating":[51],"correctly":[52],"in":[53,79,142,201,215],"response":[54],"its":[56],"inputs,":[57],"including":[58],"safe":[60],"management":[61],"likely":[63],"operator":[64],"errors,":[65],"hardware":[66],"failures":[67],"and":[68,84,87,95,128,182,186,193,226],"environmental":[69],"changes.":[70],"basic":[72],"principles":[73],"were":[77],"developed":[78],"military":[81],"field,":[82],"nuclear":[83],"aerospace":[85],"industry,":[86],"then":[88,194],"taken":[89],"up":[90],"by":[91,251],"rail":[92],"transportation,":[93],"process":[94],"Oil&Gas":[96],"industries":[97],"have":[99],"required":[100],"development":[102],"sector":[104],"specific":[105],"standards.":[106],"According":[107],"Standard":[110],"IEC61508,":[111],"paper":[113,205],"presents":[114],"case":[116],"study":[117],"concerning":[118],"evaluation":[120],"both":[122],"Safe":[124],"Failure":[125,132,179],"Fraction":[126],"(SFF)":[127],"Probability":[130],"demand":[134],"(PFD)":[135],"for":[136,154,231],"complex":[138,235],"Oil":[143],"&":[144],"Gas":[145],"application.":[146],"After":[147],"preliminary":[149],"presentation":[150],"criteria":[153],"SIL":[156],"(Safety":[157],"Integrity":[158],"Level)":[159],"verification,":[160],"work":[162],"focuses":[163],"attention":[165,222],"method":[168],"achieve":[170],"PFD.":[172],"In":[173],"particular,":[174],"an":[175],"approach":[176,199],"based":[177],"Modes,":[180],"Effects":[181],"Diagnostic":[183],"Analysis":[184],"(FMEDA)":[185],"Reliability":[187],"Block":[188],"Diagram":[189],"(RBD)":[190],"proposed":[192],"comparison":[196],"with":[197,219],"described":[200],"Standard.":[203],"aims":[206],"clarify":[208],"how":[209],"demonstrate":[211],"compliance":[212],"IEC61508":[214],"OIL&":[216],"GAS":[217],"application,":[218],"particular":[221],"steam":[224],"turbine,":[225],"proposes":[227],"simplified":[229],"technique":[230],"reliability":[232],"analysis":[233],"System,":[238],"taking":[239],"into":[240],"account":[241],"methods":[244],"should":[245],"still":[246],"be":[247],"possible":[248],"comprehend":[250],"design":[252],"engineers.":[253]},"counts_by_year":[{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":5}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}