{"id":"https://openalex.org/W2783415514","doi":"https://doi.org/10.1109/glocom.2017.8255071","title":"Online Temperature Control of a Residential Building in Smart Grid Environment","display_name":"Online Temperature Control of a Residential Building in Smart Grid Environment","publication_year":2017,"publication_date":"2017-12-01","ids":{"openalex":"https://openalex.org/W2783415514","doi":"https://doi.org/10.1109/glocom.2017.8255071","mag":"2783415514"},"language":"en","primary_location":{"id":"doi:10.1109/glocom.2017.8255071","is_oa":false,"landing_page_url":"https://doi.org/10.1109/glocom.2017.8255071","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"GLOBECOM 2017 - 2017 IEEE Global Communications Conference","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026971814","display_name":"Liang Yu","orcid":"https://orcid.org/0000-0001-5015-0320"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liang Yu","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, P. R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, P. R. China","institution_ids":["https://openalex.org/I41198531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100678341","display_name":"Tao Jiang","orcid":"https://orcid.org/0000-0002-8482-1046"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Jiang","raw_affiliation_strings":["School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, P. R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, P. R. China","institution_ids":["https://openalex.org/I47720641"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5090513264","display_name":"Yulong Zou","orcid":"https://orcid.org/0000-0002-8461-5306"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yulong Zou","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, P. R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, P. R. China","institution_ids":["https://openalex.org/I41198531"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9796000123023987,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9510583877563477},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6382416486740112},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.6271036863327026},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.61262047290802},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.565528154373169},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.5555452108383179},{"id":"https://openalex.org/keywords/lyapunov-optimization","display_name":"Lyapunov optimization","score":0.5286208391189575},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5210687518119812},{"id":"https://openalex.org/keywords/building-automation","display_name":"Building automation","score":0.4889282286167145},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.46743693947792053},{"id":"https://openalex.org/keywords/minification","display_name":"Minification","score":0.45797061920166016},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.4303804337978363},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4193198084831238},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.41706743836402893},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.4150685667991638},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.401900976896286},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.38230425119400024},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3662671446800232},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.319577693939209},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2265106439590454},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11261266469955444},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.09067562222480774},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08352833986282349},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.08244600892066956}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9510583877563477},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6382416486740112},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.6271036863327026},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.61262047290802},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.565528154373169},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5555452108383179},{"id":"https://openalex.org/C101403955","wikidata":"https://www.wikidata.org/wiki/Q6707083","display_name":"Lyapunov optimization","level":5,"score":0.5286208391189575},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5210687518119812},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.4889282286167145},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.46743693947792053},{"id":"https://openalex.org/C147764199","wikidata":"https://www.wikidata.org/wiki/Q6865248","display_name":"Minification","level":2,"score":0.45797061920166016},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4303804337978363},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4193198084831238},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.41706743836402893},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.4150685667991638},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.401900976896286},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.38230425119400024},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3662671446800232},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.319577693939209},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2265106439590454},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11261266469955444},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.09067562222480774},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08352833986282349},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.08244600892066956},{"id":"https://openalex.org/C37935115","wikidata":"https://www.wikidata.org/wiki/Q6707085","display_name":"Lyapunov redesign","level":4,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C191544260","wikidata":"https://www.wikidata.org/wiki/Q1238630","display_name":"Lyapunov exponent","level":3,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C2777052490","wikidata":"https://www.wikidata.org/wiki/Q5072826","display_name":"Chaotic","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/glocom.2017.8255071","is_oa":false,"landing_page_url":"https://doi.org/10.1109/glocom.2017.8255071","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"GLOBECOM 2017 - 2017 IEEE Global Communications Conference","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8999999761581421,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1965345917","https://openalex.org/W1997016889","https://openalex.org/W2000603147","https://openalex.org/W2002316308","https://openalex.org/W2033202841","https://openalex.org/W2045174200","https://openalex.org/W2063512148","https://openalex.org/W2064977675","https://openalex.org/W2068375961","https://openalex.org/W2079278498","https://openalex.org/W2137152139","https://openalex.org/W2306906380","https://openalex.org/W2317595689","https://openalex.org/W2321621839","https://openalex.org/W2345637415","https://openalex.org/W2400453077","https://openalex.org/W2508114006","https://openalex.org/W2513935212","https://openalex.org/W2584025288","https://openalex.org/W2588174609","https://openalex.org/W2598501126","https://openalex.org/W2738332640","https://openalex.org/W4301852635","https://openalex.org/W6700271283"],"related_works":["https://openalex.org/W2749654269","https://openalex.org/W2326668440","https://openalex.org/W4390970874","https://openalex.org/W2538009942","https://openalex.org/W2735458449","https://openalex.org/W3031841740","https://openalex.org/W4240359851","https://openalex.org/W2604419375","https://openalex.org/W2296534813","https://openalex.org/W2329485921"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3,34,92],"investigate":[4],"the":[5,38,43,54,70,84,90,117],"problem":[6],"of":[7,19,45,62],"energy":[8,46,122],"management":[9],"for":[10],"an":[11,94],"HVAC":[12,55,96],"(Heating,":[13],"Ventilation,":[14],"and":[15,48,65],"Air":[16],"Conditioning)":[17],"system":[18,56],"a":[20],"residential":[21],"building":[22],"in":[23,128],"smart":[24],"grid":[25],"environment":[26],"without":[27,104],"violating":[28],"user":[29],"thermal":[30,49,129],"comfort":[31],"limits.":[32],"Specifically,":[33],"intend":[35],"to":[36,69,82],"minimize":[37],"long-term":[39],"total":[40],"cost":[41,47,123],"(i.e.,":[42],"sum":[44],"discomfort":[50],"cost)":[51],"associated":[52],"with":[53,125],"by":[57,74],"taking":[58],"into":[59],"account":[60],"uncertainties":[61],"outdoor":[63],"temperature":[64,76],"electricity":[66],"price.":[67],"Due":[68],"time":[71],"coupling":[72],"incurred":[73],"indoor":[75],"dynamics,":[77],"it":[78],"is":[79],"very":[80],"challenging":[81],"solve":[83],"formulated":[85],"minimization":[86],"problem.":[87],"To":[88],"address":[89],"challenge,":[91],"propose":[93],"online":[95],"control":[97],"algorithm":[98,119],"based":[99,111],"on":[100,112],"Lyapunov":[101],"optimization":[102],"techniques":[103],"requiring":[105],"any":[106],"parameter":[107],"predictions.":[108],"Simulation":[109],"results":[110],"real-world":[113],"traces":[114],"show":[115],"that":[116],"proposed":[118],"can":[120],"reduce":[121],"significantly":[124],"small":[126],"sacrifice":[127],"comfort.":[130]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2018,"cited_by_count":1}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
