{"id":"https://openalex.org/W2033527234","doi":"https://doi.org/10.1109/glocom.2012.6503971","title":"OWER-MDG: A novel energy replenishment and data gathering mechanism in wireless rechargeable sensor networks","display_name":"OWER-MDG: A novel energy replenishment and data gathering mechanism in wireless rechargeable sensor networks","publication_year":2012,"publication_date":"2012-12-01","ids":{"openalex":"https://openalex.org/W2033527234","doi":"https://doi.org/10.1109/glocom.2012.6503971","mag":"2033527234"},"language":"en","primary_location":{"id":"doi:10.1109/glocom.2012.6503971","is_oa":false,"landing_page_url":"https://doi.org/10.1109/glocom.2012.6503971","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Global Communications Conference (GLOBECOM)","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100421167","display_name":"Ji Li","orcid":"https://orcid.org/0000-0002-9733-567X"},"institutions":[{"id":"https://openalex.org/I59553526","display_name":"Stony Brook University","ror":"https://ror.org/05qghxh33","country_code":"US","type":"education","lineage":["https://openalex.org/I59553526"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ji Li","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA","institution_ids":["https://openalex.org/I59553526"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074355807","display_name":"Miao Zhao","orcid":"https://orcid.org/0000-0002-4324-1467"},"institutions":[{"id":"https://openalex.org/I59553526","display_name":"Stony Brook University","ror":"https://ror.org/05qghxh33","country_code":"US","type":"education","lineage":["https://openalex.org/I59553526"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Miao Zhao","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA","institution_ids":["https://openalex.org/I59553526"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100638446","display_name":"Yuanyuan Yang","orcid":"https://orcid.org/0000-0001-7296-9222"},"institutions":[{"id":"https://openalex.org/I59553526","display_name":"Stony Brook University","ror":"https://ror.org/05qghxh33","country_code":"US","type":"education","lineage":["https://openalex.org/I59553526"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yuanyuan Yang","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Stony Brook University, New York 11794, USA","institution_ids":["https://openalex.org/I59553526"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I59553526"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"5350","last_page":"5355"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10080","display_name":"Energy Efficient Wireless Sensor Networks","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11896","display_name":"Opportunistic and Delay-Tolerant Networks","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.8177214860916138},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.6685077548027039},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.624786376953125},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6062430739402771},{"id":"https://openalex.org/keywords/key-distribution-in-wireless-sensor-networks","display_name":"Key distribution in wireless sensor networks","score":0.5157180428504944},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.4967840015888214},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.4675634801387787},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.46562713384628296},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4560714364051819},{"id":"https://openalex.org/keywords/data-collection","display_name":"Data collection","score":0.42767658829689026},{"id":"https://openalex.org/keywords/wireless-network","display_name":"Wireless network","score":0.3893986940383911},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.35948842763900757},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.251299113035202},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.16732066869735718},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16153520345687866}],"concepts":[{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.8177214860916138},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6685077548027039},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.624786376953125},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6062430739402771},{"id":"https://openalex.org/C41971633","wikidata":"https://www.wikidata.org/wiki/Q6398155","display_name":"Key distribution in wireless sensor networks","level":4,"score":0.5157180428504944},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.4967840015888214},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.4675634801387787},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.46562713384628296},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4560714364051819},{"id":"https://openalex.org/C133462117","wikidata":"https://www.wikidata.org/wiki/Q4929239","display_name":"Data collection","level":2,"score":0.42767658829689026},{"id":"https://openalex.org/C108037233","wikidata":"https://www.wikidata.org/wiki/Q11375","display_name":"Wireless network","level":3,"score":0.3893986940383911},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35948842763900757},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.251299113035202},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.16732066869735718},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16153520345687866},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/glocom.2012.6503971","is_oa":false,"landing_page_url":"https://doi.org/10.1109/glocom.2012.6503971","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2012 IEEE Global Communications Conference (GLOBECOM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320337392","display_name":"Division of Electrical, Communications and Cyber Systems","ror":"https://ror.org/01krpsy48"},{"id":"https://openalex.org/F4320338281","display_name":"Army Research Office","ror":"https://ror.org/05epdh915"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W62859474","https://openalex.org/W1549351543","https://openalex.org/W1985705155","https://openalex.org/W2001308229","https://openalex.org/W2024565483","https://openalex.org/W2042455779","https://openalex.org/W2081198853","https://openalex.org/W2087003981","https://openalex.org/W2105749622","https://openalex.org/W2107570439","https://openalex.org/W2108559600","https://openalex.org/W2114706710","https://openalex.org/W2120680597","https://openalex.org/W2126335077","https://openalex.org/W2127287364","https://openalex.org/W2132398059","https://openalex.org/W2152589112","https://openalex.org/W2171386318","https://openalex.org/W2172926568","https://openalex.org/W2176114055","https://openalex.org/W6632848010","https://openalex.org/W6684778415"],"related_works":["https://openalex.org/W1975451135","https://openalex.org/W917005982","https://openalex.org/W2148549110","https://openalex.org/W2295628284","https://openalex.org/W2890570089","https://openalex.org/W3095958166","https://openalex.org/W2129477171","https://openalex.org/W2593729912","https://openalex.org/W3148968234","https://openalex.org/W2012250365"],"abstract_inverted_index":{"Current":[0],"study":[1,108],"on":[2,12,137],"prolonging":[3],"lifetime":[4,58],"for":[5,68,140],"wireless":[6,82],"sensor":[7,24,33,93],"networks":[8],"(WSNs)":[9],"mainly":[10],"focuses":[11],"two":[13,51],"techniques.":[14],"The":[15],"first":[16],"technique":[17,29],"is":[18,30],"to":[19,31,55,64],"reduce":[20],"energy":[21,37,45,83],"consumption":[22],"of":[23,49,111,131],"nodes,":[25],"while":[26,70],"the":[27,39,100,109,128],"second":[28],"recharge":[32],"nodes":[34,94],"by":[35],"harvesting":[36],"from":[38,99],"ambient":[40],"environment":[41],"or":[42],"RF":[43],"based":[44],"transmission.":[46],"However,":[47],"neither":[48],"these":[50],"techniques":[52],"are":[53],"able":[54],"guarantee":[56],"network":[57,60,73,101,122],"and":[59,85,96,115,133],"performance.":[61],"In":[62],"order":[63],"achieve":[65],"perpetual":[66],"operation":[67],"WSNs":[69,114],"providing":[71],"high":[72],"utility,":[74],"in":[75,113],"this":[76],"paper":[77],"we":[78],"propose":[79],"an":[80,117],"optimal":[81],"replenishment":[84],"mobile":[86,104],"data":[87,98],"gathering":[88],"mechanism":[89],"(OWER-MDG)":[90],"which":[91,120],"charges":[92],"effectively":[95],"collects":[97],"using":[102],"a":[103,135],"vehicle":[105],"(SenCar).":[106],"We":[107],"application":[110],"OWER-MDG":[112,132],"provide":[116,134],"efficient":[118],"algorithm":[119],"maximizes":[121],"utility.":[123],"Our":[124],"numerical":[125],"results":[126],"demonstrate":[127],"performance":[129],"advantage":[130],"guidance":[136],"parameter":[138],"selection":[139],"system":[141],"design.":[142]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":3}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
