{"id":"https://openalex.org/W2288998606","doi":"https://doi.org/10.1109/globalsip.2015.7418248","title":"Energy and workload management for data centers in renewable-integrated power grid","display_name":"Energy and workload management for data centers in renewable-integrated power grid","publication_year":2015,"publication_date":"2015-12-01","ids":{"openalex":"https://openalex.org/W2288998606","doi":"https://doi.org/10.1109/globalsip.2015.7418248","mag":"2288998606"},"language":"en","primary_location":{"id":"doi:10.1109/globalsip.2015.7418248","is_oa":false,"landing_page_url":"https://doi.org/10.1109/globalsip.2015.7418248","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Global Conference on Signal and Information Processing (GlobalSIP)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100783476","display_name":"Tianyi Chen","orcid":"https://orcid.org/0000-0003-3477-1439"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Tianyi Chen","raw_affiliation_strings":["Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA"],"affiliations":[{"raw_affiliation_string":"Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061028507","display_name":"Xin Wang","orcid":"https://orcid.org/0000-0001-8969-1415"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xin Wang","raw_affiliation_strings":["Dept. of CSE and Key Lab for Inf. Sci. of EMW (MoE), Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Dept. of CSE and Key Lab for Inf. Sci. of EMW (MoE), Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5026758314","display_name":"Georgios B. Giannakis","orcid":"https://orcid.org/0000-0002-0196-0260"},"institutions":[{"id":"https://openalex.org/I130238516","display_name":"University of Minnesota","ror":"https://ror.org/017zqws13","country_code":"US","type":"education","lineage":["https://openalex.org/I130238516"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Georgios B. Giannakis","raw_affiliation_strings":["Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA"],"affiliations":[{"raw_affiliation_string":"Dept. of ECE and DTC, University of Minnesota, Minneapolis, USA","institution_ids":["https://openalex.org/I130238516"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5100783476"],"corresponding_institution_ids":["https://openalex.org/I130238516"],"apc_list":null,"apc_paid":null,"fwci":1.5892,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.88659812,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"513","last_page":"517"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9941999912261963,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.7552788257598877},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6863398551940918},{"id":"https://openalex.org/keywords/workload","display_name":"Workload","score":0.667772114276886},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5196905732154846},{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.4891557991504669},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.47973600029945374},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.4580179750919342},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.44291767477989197},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4379817247390747},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.4256994426250458},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.41501113772392273},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.39085474610328674},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.16148856282234192},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.1571444272994995},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14770659804344177},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12960249185562134}],"concepts":[{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.7552788257598877},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6863398551940918},{"id":"https://openalex.org/C2778476105","wikidata":"https://www.wikidata.org/wiki/Q628539","display_name":"Workload","level":2,"score":0.667772114276886},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5196905732154846},{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.4891557991504669},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.47973600029945374},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.4580179750919342},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.44291767477989197},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4379817247390747},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.4256994426250458},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.41501113772392273},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.39085474610328674},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.16148856282234192},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.1571444272994995},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14770659804344177},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12960249185562134},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/globalsip.2015.7418248","is_oa":false,"landing_page_url":"https://doi.org/10.1109/globalsip.2015.7418248","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2015 IEEE Global Conference on Signal and Information Processing (GlobalSIP)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W633277346","https://openalex.org/W1529917160","https://openalex.org/W1969353386","https://openalex.org/W1987328208","https://openalex.org/W2005318779","https://openalex.org/W2035694933","https://openalex.org/W2052671641","https://openalex.org/W2082034273","https://openalex.org/W2084727684","https://openalex.org/W2107128713","https://openalex.org/W2166909680","https://openalex.org/W2276903495","https://openalex.org/W6671571921","https://openalex.org/W6694817546"],"related_works":["https://openalex.org/W2109838025","https://openalex.org/W2132220153","https://openalex.org/W3040891731","https://openalex.org/W3132924010","https://openalex.org/W2146738646","https://openalex.org/W2294404101","https://openalex.org/W1587497630","https://openalex.org/W2556225243","https://openalex.org/W2041350240","https://openalex.org/W2536329638","https://openalex.org/W2524390376","https://openalex.org/W3155635579","https://openalex.org/W2028218361","https://openalex.org/W1529360552","https://openalex.org/W2539857294","https://openalex.org/W2927769599","https://openalex.org/W1996251538","https://openalex.org/W3202465530","https://openalex.org/W2921707165","https://openalex.org/W2963114049"],"abstract_inverted_index":{"Recent":[0],"advances":[1],"such":[2],"as":[3],"high":[4],"penetration":[5],"of":[6,9,15,86],"renewables,":[7],"development":[8],"energy-efficient":[10],"cooling":[11,53],"facilities,":[12],"and":[13,25,58,78,90],"flexibility":[14],"distributed":[16],"storage":[17],"units,":[18],"all":[19],"call":[20],"for":[21,29],"a":[22,38,76],"system-wide":[23],"energy":[24,59],"workload":[26,56],"management":[27,40,80],"policy":[28],"future":[30],"sustainable":[31],"data":[32,45],"centers.":[33],"Leveraging":[34],"stochastic":[35],"optimization":[36],"tools,":[37],"unified":[39],"approach":[41],"is":[42,68],"proposed":[43,73],"allowing":[44],"centers":[46],"to":[47,50],"adaptively":[48],"respond":[49],"renewable":[51],"availability,":[52],"efficiency":[54],"variation,":[55],"shift,":[57],"price":[60,92],"fluctuation":[61],"under":[62],"long-term":[63],"quality-of-service":[64],"(QoS)":[65],"requirements.":[66],"It":[67],"rigorously":[69],"established":[70],"that":[71],"the":[72,84],"algorithm":[74],"yields":[75],"feasible":[77],"near-optimal":[79],"strategy":[81],"without":[82],"knowing":[83],"distributions":[85],"random":[87],"workload,":[88],"renewable,":[89],"electricity":[91],"processes.":[93]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
