{"id":"https://openalex.org/W2152295220","doi":"https://doi.org/10.1109/fuzz.2003.1206635","title":"Control of power-plant main steam pressure and power output based on fuzzy reasoning and auto-tuning","display_name":"Control of power-plant main steam pressure and power output based on fuzzy reasoning and auto-tuning","publication_year":2004,"publication_date":"2004-03-22","ids":{"openalex":"https://openalex.org/W2152295220","doi":"https://doi.org/10.1109/fuzz.2003.1206635","mag":"2152295220"},"language":"en","primary_location":{"id":"doi:10.1109/fuzz.2003.1206635","is_oa":false,"landing_page_url":"https://doi.org/10.1109/fuzz.2003.1206635","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 12th IEEE International Conference on Fuzzy Systems, 2003. FUZZ '03.","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101684232","display_name":"Hongbo Liu","orcid":"https://orcid.org/0000-0002-7404-4271"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Hongbo Liu","raw_affiliation_strings":["Institute of Automatics, Shanghai JiaoTong University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Institute of Automatics, Shanghai JiaoTong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5107750031","display_name":"Shaoyuan Li","orcid":null},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shaoyuan Li","raw_affiliation_strings":["Institute of Automatics, Shanghai JiaoTong University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Institute of Automatics, Shanghai JiaoTong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042520521","display_name":"Tianyou Chai","orcid":"https://orcid.org/0000-0002-4623-1483"},"institutions":[{"id":"https://openalex.org/I9224756","display_name":"Northeastern University","ror":"https://ror.org/03awzbc87","country_code":"CN","type":"education","lineage":["https://openalex.org/I9224756"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tianyou Chai","raw_affiliation_strings":["Research Center of Automation, Northeastern University, Shenyang, China"],"affiliations":[{"raw_affiliation_string":"Research Center of Automation, Northeastern University, Shenyang, China","institution_ids":["https://openalex.org/I9224756"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101684232"],"corresponding_institution_ids":["https://openalex.org/I183067930"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.121438,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"2","issue":null,"first_page":"1395","last_page":"1400"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10791","display_name":"Advanced Control Systems Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10820","display_name":"Fuzzy Logic and Control Systems","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6598547697067261},{"id":"https://openalex.org/keywords/boiler","display_name":"Boiler (water heating)","score":0.6479024291038513},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.5436531901359558},{"id":"https://openalex.org/keywords/fuzzy-logic","display_name":"Fuzzy logic","score":0.5202652215957642},{"id":"https://openalex.org/keywords/fuzzy-control-system","display_name":"Fuzzy control system","score":0.5136167407035828},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.5068500638008118},{"id":"https://openalex.org/keywords/settling-time","display_name":"Settling time","score":0.49640709161758423},{"id":"https://openalex.org/keywords/pid-controller","display_name":"PID controller","score":0.49360978603363037},{"id":"https://openalex.org/keywords/power-station","display_name":"Power station","score":0.4829508662223816},{"id":"https://openalex.org/keywords/feedwater-heater","display_name":"Feedwater heater","score":0.47323736548423767},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.47116905450820923},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.41510653495788574},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4098215699195862},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.3968762159347534},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3493803143501282},{"id":"https://openalex.org/keywords/steam-electric-power-station","display_name":"Steam-electric power station","score":0.32644400000572205},{"id":"https://openalex.org/keywords/step-response","display_name":"Step response","score":0.2219795286655426},{"id":"https://openalex.org/keywords/temperature-control","display_name":"Temperature control","score":0.21961215138435364},{"id":"https://openalex.org/keywords/combined-cycle","display_name":"Combined cycle","score":0.19559183716773987},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14665430784225464},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1231357753276825},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10042986273765564}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6598547697067261},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.6479024291038513},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5436531901359558},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.5202652215957642},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.5136167407035828},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.5068500638008118},{"id":"https://openalex.org/C14781684","wikidata":"https://www.wikidata.org/wiki/Q3983320","display_name":"Settling time","level":3,"score":0.49640709161758423},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.49360978603363037},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4829508662223816},{"id":"https://openalex.org/C33666660","wikidata":"https://www.wikidata.org/wiki/Q17144732","display_name":"Feedwater heater","level":5,"score":0.47323736548423767},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.47116905450820923},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.41510653495788574},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4098215699195862},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.3968762159347534},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3493803143501282},{"id":"https://openalex.org/C73673526","wikidata":"https://www.wikidata.org/wiki/Q1158818","display_name":"Steam-electric power station","level":4,"score":0.32644400000572205},{"id":"https://openalex.org/C160030872","wikidata":"https://www.wikidata.org/wiki/Q2142864","display_name":"Step response","level":2,"score":0.2219795286655426},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.21961215138435364},{"id":"https://openalex.org/C110910425","wikidata":"https://www.wikidata.org/wiki/Q900729","display_name":"Combined cycle","level":3,"score":0.19559183716773987},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14665430784225464},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1231357753276825},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10042986273765564},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/fuzz.2003.1206635","is_oa":false,"landing_page_url":"https://doi.org/10.1109/fuzz.2003.1206635","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"The 12th IEEE International Conference on Fuzzy Systems, 2003. FUZZ '03.","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7900000214576721,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1972789657","https://openalex.org/W2065205584","https://openalex.org/W2161700509","https://openalex.org/W2724164316","https://openalex.org/W6683651216","https://openalex.org/W6740245525"],"related_works":["https://openalex.org/W4391488671","https://openalex.org/W2478720371","https://openalex.org/W1485610676","https://openalex.org/W2355092493","https://openalex.org/W1595260021","https://openalex.org/W2367406672","https://openalex.org/W2915179349","https://openalex.org/W1987592350","https://openalex.org/W2379246248","https://openalex.org/W2902433414"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,7,51,63,73,83,95,104,136],"new":[4],"development":[5],"of":[6,41,46,94,107],"boiler-turbine":[8,19],"coordinated":[9],"control":[10,112,128,141],"system":[11,20,129],"using":[12],"fuzzy":[13,47],"reasoning":[14],"and":[15,38,76,99,133,139,143],"auto-tuning":[16,118],"techniques.":[17],"The":[18],"is":[21,27,59],"a":[22,28,39,110,127],"very":[23],"complex":[24,137],"process":[25],"which":[26],"multivariable,":[29],"nonlinear,":[30],"slowly":[31],"time-varying":[32],"plant":[33,100],"with":[34,54],"large":[35,105],"settling":[36],"time":[37],"lot":[40],"uncertainties.":[42],"A":[43],"special":[44],"subclass":[45],"inference":[48],"systems,":[49,58],"called":[50],"GPE(Gaussian":[52],"partition":[53],"evenly":[55],"spaced":[56],"midpoints)":[57],"used":[60],"to":[61,86,135],"self-tune":[62],"main":[64],"steam":[65],"pressure":[66],"PID":[67],"controller's":[68],"parameters":[69],"on-line":[70],"based":[71],"on":[72],"error":[74],"signal":[75],"its":[77],"first":[78],"difference,":[79],"aimed":[80],"at":[81],"overcoming":[82],"uncertainties":[84],"due":[85],"changing":[87],"fuel":[88],"calorific":[89],"value,":[90],"machine":[91],"wear,":[92],"contamination":[93],"boiler":[96],"heating":[97],"surfaces":[98],"modeling":[101],"errors.":[102],"For":[103],"variation":[106],"operating":[108],"condition,":[109],"supervisory":[111],"level":[113],"has":[114,130,147],"been":[115,148],"developed":[116],"by":[117],"technique.":[119],"Satisfactory":[120],"industrial":[121],"application":[122],"results":[123],"show":[124],"that":[125],"such":[126],"enhanced":[131],"adaptability":[132],"robustness":[134],"process,":[138],"better":[140],"performance":[142],"high":[144],"economic":[145],"benefit":[146],"obtained.":[149]},"counts_by_year":[{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}