{"id":"https://openalex.org/W2770790570","doi":"https://doi.org/10.1109/ewdts.2017.8110143","title":"Diagnostics and monitoring of railway automation and remote control power supply devices","display_name":"Diagnostics and monitoring of railway automation and remote control power supply devices","publication_year":2017,"publication_date":"2017-09-01","ids":{"openalex":"https://openalex.org/W2770790570","doi":"https://doi.org/10.1109/ewdts.2017.8110143","mag":"2770790570"},"language":"en","primary_location":{"id":"doi:10.1109/ewdts.2017.8110143","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ewdts.2017.8110143","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE East-West Design &amp; Test Symposium (EWDTS)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5061539948","display_name":"Alexey Poroshin","orcid":null},"institutions":[{"id":"https://openalex.org/I7888777","display_name":"Petersburg State Transport University","ror":"https://ror.org/02fh3dt13","country_code":"RU","type":"education","lineage":["https://openalex.org/I7888777"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Alexey Poroshin","raw_affiliation_strings":["Department Emperor Alexander I, St. Petersburg State Transport University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department Emperor Alexander I, St. Petersburg State Transport University","institution_ids":["https://openalex.org/I7888777"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045534208","display_name":"Alexander B. Nikitin","orcid":"https://orcid.org/0000-0003-4431-1209"},"institutions":[{"id":"https://openalex.org/I7888777","display_name":"Petersburg State Transport University","ror":"https://ror.org/02fh3dt13","country_code":"RU","type":"education","lineage":["https://openalex.org/I7888777"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Alexander Nikitin","raw_affiliation_strings":["Department Emperor Alexander I, St. Petersburg State Transport University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department Emperor Alexander I, St. Petersburg State Transport University","institution_ids":["https://openalex.org/I7888777"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003343226","display_name":"Vitaly Shatokhin","orcid":"https://orcid.org/0009-0007-4825-2599"},"institutions":[{"id":"https://openalex.org/I7888777","display_name":"Petersburg State Transport University","ror":"https://ror.org/02fh3dt13","country_code":"RU","type":"education","lineage":["https://openalex.org/I7888777"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Vitaly Shatokhin","raw_affiliation_strings":["Department Emperor Alexander I, St. Petersburg State Transport University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department Emperor Alexander I, St. Petersburg State Transport University","institution_ids":["https://openalex.org/I7888777"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5010606794","display_name":"Alexey Kotenko","orcid":"https://orcid.org/0000-0003-1638-9965"},"institutions":[{"id":"https://openalex.org/I7888777","display_name":"Petersburg State Transport University","ror":"https://ror.org/02fh3dt13","country_code":"RU","type":"education","lineage":["https://openalex.org/I7888777"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"Alexey Kotenko","raw_affiliation_strings":["Department Emperor Alexander I, St. Petersburg State Transport University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department Emperor Alexander I, St. Petersburg State Transport University","institution_ids":["https://openalex.org/I7888777"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6123,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.71282229,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14420","display_name":"Advanced Research in Systems and Signal Processing","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14420","display_name":"Advanced Research in Systems and Signal Processing","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.986299991607666,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11568","display_name":"Railway Systems and Energy Efficiency","score":0.9861999750137329,"subfield":{"id":"https://openalex.org/subfields/2209","display_name":"Industrial and Manufacturing Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backup","display_name":"Backup","score":0.7822189331054688},{"id":"https://openalex.org/keywords/switchgear","display_name":"Switchgear","score":0.7355449795722961},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7152305841445923},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.7104672789573669},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.6841541528701782},{"id":"https://openalex.org/keywords/survivability","display_name":"Survivability","score":0.6468288898468018},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5114623308181763},{"id":"https://openalex.org/keywords/remote-control","display_name":"Remote control","score":0.4846344590187073},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4498823285102844},{"id":"https://openalex.org/keywords/switched-mode-power-supply-applications","display_name":"Switched-mode power supply applications","score":0.4400847852230072},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4199199676513672},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.38256508111953735},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.36114490032196045},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.3021169602870941},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.28432154655456543},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.09864124655723572}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.7822189331054688},{"id":"https://openalex.org/C93893174","wikidata":"https://www.wikidata.org/wiki/Q1273786","display_name":"Switchgear","level":2,"score":0.7355449795722961},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7152305841445923},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.7104672789573669},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6841541528701782},{"id":"https://openalex.org/C2781133158","wikidata":"https://www.wikidata.org/wiki/Q1088669","display_name":"Survivability","level":2,"score":0.6468288898468018},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5114623308181763},{"id":"https://openalex.org/C557691694","wikidata":"https://www.wikidata.org/wiki/Q185091","display_name":"Remote control","level":2,"score":0.4846344590187073},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4498823285102844},{"id":"https://openalex.org/C79899660","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply applications","level":5,"score":0.4400847852230072},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4199199676513672},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38256508111953735},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.36114490032196045},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.3021169602870941},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28432154655456543},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.09864124655723572},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ewdts.2017.8110143","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ewdts.2017.8110143","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2017 IEEE East-West Design &amp; Test Symposium (EWDTS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2386849760","https://openalex.org/W2371073454","https://openalex.org/W2359850098","https://openalex.org/W2740815748","https://openalex.org/W2889535154","https://openalex.org/W2356496350","https://openalex.org/W2355760591","https://openalex.org/W2171669067","https://openalex.org/W2360022791","https://openalex.org/W2297005396"],"abstract_inverted_index":{"This":[0],"article":[1,116],"is":[2],"devoted":[3],"to":[4,137],"the":[5,38,55,63,71,75,78,82,94,102,122,142,145,156,163],"research":[6],"of":[7,11,15,23,26,42,57,74,84,104,110,124,126,144,148,162],"diagnostics":[8,125],"and":[9,18,37,77,150,160],"monitoring":[10],"power":[12,27,43,80,105,113,146],"supply":[13,28,44,106,147],"devices":[14,29,107],"railway":[16],"automation":[17,149],"remote":[19,151],"control.":[20],"The":[21,91,115],"analysis":[22],"failure":[24],"statistics":[25],"in":[30,62,66,108],"recent":[31],"years":[32],"has":[33],"been":[34,47],"carried":[35],"out":[36],"most":[39],"vulnerable":[40],"elements":[41],"systems":[45],"have":[46],"identified":[48],"on":[49,135],"its":[50],"basis.":[51],"Objects":[52],"are":[53,89],"described,":[54],"state":[56],"which":[58,129,153],"must":[59],"be":[60],"diagnosed":[61],"input":[64],"devices,":[65],"switchgears,":[67],"as":[68,70],"well":[69],"diagnostic":[72],"parameters":[73],"battery":[76],"backup":[79],"station;":[81],"principles":[83],"determining":[85],"their":[86],"technical":[87,98],"condition":[88],"presented.":[90],"authors":[92],"for":[93,100,121],"first":[95],"time":[96,131],"proposed":[97],"solutions":[99,120],"increasing":[101],"survivability":[103],"case":[109],"poor-quality":[111],"external":[112],"supply.":[114],"also":[117],"presents":[118],"possible":[119],"implementation":[123],"monitored":[127],"facilities,":[128],"save":[130],"spent":[132],"by":[133],"personnel":[134],"maintenance":[136],"reduce":[138],"operational":[139],"costs,":[140],"improve":[141,155],"reliability":[143],"control,":[152],"will":[154],"safety,":[157],"uninterrupted":[158],"operation":[159],"efficiency":[161],"transportation":[164],"process.":[165]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
