{"id":"https://openalex.org/W2803899173","doi":"https://doi.org/10.1109/ever.2018.8362370","title":"Experimental verification of the normative thermal stability of a MOSFET full bridge power inverter","display_name":"Experimental verification of the normative thermal stability of a MOSFET full bridge power inverter","publication_year":2018,"publication_date":"2018-04-01","ids":{"openalex":"https://openalex.org/W2803899173","doi":"https://doi.org/10.1109/ever.2018.8362370","mag":"2803899173"},"language":"en","primary_location":{"id":"doi:10.1109/ever.2018.8362370","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ever.2018.8362370","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Thirteenth International Conference on Ecological Vehicles and Renewable Energies (EVER)","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"http://mediatum.ub.tum.de/node?id=1452558","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056628127","display_name":"Igor Bolvashenkov","orcid":"https://orcid.org/0000-0002-4212-5827"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Igor Bolvashenkov","raw_affiliation_strings":["Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082772677","display_name":"Taha Lahlou","orcid":null},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Taha Lahlou","raw_affiliation_strings":["Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018442305","display_name":"Hans\u2013Georg Herzog","orcid":"https://orcid.org/0000-0002-2143-0929"},"institutions":[{"id":"https://openalex.org/I62916508","display_name":"Technical University of Munich","ror":"https://ror.org/02kkvpp62","country_code":"DE","type":"education","lineage":["https://openalex.org/I62916508"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Hans-Georg Herzog","raw_affiliation_strings":["Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Institute of Energy Conversion Technology, Technical University of Munich, Munich, Germany","institution_ids":["https://openalex.org/I62916508"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I62916508"],"apc_list":null,"apc_paid":null,"fwci":0.1309,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.47007367,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"27","issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.7374690175056458},{"id":"https://openalex.org/keywords/mosfet","display_name":"MOSFET","score":0.6266908049583435},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.5547731518745422},{"id":"https://openalex.org/keywords/power-electronics","display_name":"Power electronics","score":0.5074703097343445},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5035862326622009},{"id":"https://openalex.org/keywords/heat-sink","display_name":"Heat sink","score":0.46139761805534363},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.42553645372390747},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.41411054134368896},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.39304259419441223},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.37705469131469727},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.16081443428993225},{"id":"https://openalex.org/keywords/transistor","display_name":"Transistor","score":0.1209462583065033}],"concepts":[{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.7374690175056458},{"id":"https://openalex.org/C2778413303","wikidata":"https://www.wikidata.org/wiki/Q210793","display_name":"MOSFET","level":4,"score":0.6266908049583435},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.5547731518745422},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.5074703097343445},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5035862326622009},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.46139761805534363},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.42553645372390747},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.41411054134368896},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39304259419441223},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.37705469131469727},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.16081443428993225},{"id":"https://openalex.org/C172385210","wikidata":"https://www.wikidata.org/wiki/Q5339","display_name":"Transistor","level":3,"score":0.1209462583065033}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/ever.2018.8362370","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ever.2018.8362370","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2018 Thirteenth International Conference on Ecological Vehicles and Renewable Energies (EVER)","raw_type":"proceedings-article"},{"id":"pmh:oai:mediatum.ub.tum.de:node/1452558","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1452558","pdf_url":null,"source":{"id":"https://openalex.org/S4377196330","display_name":"mediaTUM  (Technical University of Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:mediatum.ub.tum.de:node/1452558","is_oa":true,"landing_page_url":"http://mediatum.ub.tum.de/node?id=1452558","pdf_url":null,"source":{"id":"https://openalex.org/S4377196330","display_name":"mediaTUM  (Technical University of Munich)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I62916508","host_organization_name":"Technical University of Munich","host_organization_lineage":["https://openalex.org/I62916508"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W1570915201","https://openalex.org/W1973466307","https://openalex.org/W1998620089","https://openalex.org/W2101885096","https://openalex.org/W2174442901","https://openalex.org/W2209175717","https://openalex.org/W2484171672","https://openalex.org/W2502766926","https://openalex.org/W2584828139","https://openalex.org/W2586402844","https://openalex.org/W2734776010","https://openalex.org/W2736291299","https://openalex.org/W6688321684","https://openalex.org/W6732710219"],"related_works":["https://openalex.org/W3031568859","https://openalex.org/W759502684","https://openalex.org/W2105990939","https://openalex.org/W1994592790","https://openalex.org/W3153323934","https://openalex.org/W2003444329","https://openalex.org/W744834552","https://openalex.org/W3146552967","https://openalex.org/W2725111953","https://openalex.org/W2020925769"],"abstract_inverted_index":{"Thermal":[0],"effects":[1],"are":[2,87,100],"important":[3],"in":[4,31],"the":[5,20,42,48,57,63,67,76,84,91],"power":[6,28],"electronics":[7],"for":[8],"battery":[9,37],"energy":[10],"storage":[11],"applications.":[12],"This":[13],"paper":[14],"presents":[15],"an":[16],"experimental":[17],"verification":[18,40],"of":[19,23,41,47,66,83,93],"thermal":[21,64],"stability":[22],"a":[24],"MOSFET":[25],"full":[26],"bridge":[27],"inverter":[29,34,52],"used":[30],"cascaded":[32],"H-bridge":[33,68],"with":[35],"split":[36],"modules.":[38],"The":[39],"norm":[43],"EN":[44],"61000-2-4":[45],"compatibility":[46],"grid":[49],"connected":[50],"multilevel":[51],"is":[53,73,79],"made":[54,89],"by":[55],"testing":[56],"submodules'":[58],"current":[59],"overload":[60],"responses.":[61],"Furthermore,":[62],"capacity":[65],"using":[69],"passive":[70],"heat":[71],"sink":[72],"analysed":[74],"and":[75,90,96],"time":[77],"constant":[78],"investigated.":[80],"Efficiency":[81],"measurements":[82],"proposed":[85],"topology":[86],"also":[88],"impacts":[92],"different":[94],"currents":[95],"PWM":[97],"switching":[98],"frequencies":[99],"presented.":[101]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
