{"id":"https://openalex.org/W2979898311","doi":"https://doi.org/10.1109/eurocon.2019.8861810","title":"Influence of PV Systems on Distribution Network Voltage Values and Power Losses: Case Study","display_name":"Influence of PV Systems on Distribution Network Voltage Values and Power Losses: Case Study","publication_year":2019,"publication_date":"2019-07-01","ids":{"openalex":"https://openalex.org/W2979898311","doi":"https://doi.org/10.1109/eurocon.2019.8861810","mag":"2979898311"},"language":"en","primary_location":{"id":"doi:10.1109/eurocon.2019.8861810","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eurocon.2019.8861810","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE EUROCON 2019 -18th International Conference on Smart Technologies","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022214363","display_name":"Danijel Topi\u0107","orcid":"https://orcid.org/0000-0003-2100-242X"},"institutions":[{"id":"https://openalex.org/I51314090","display_name":"University of Osijek","ror":"https://ror.org/05sw4wc49","country_code":"HR","type":"education","lineage":["https://openalex.org/I51314090"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Danijel Topic","raw_affiliation_strings":["Faculty of Electrical Engineering, Computer Science and Information Technology University of Osijek, Osijek, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Computer Science and Information Technology University of Osijek, Osijek, Croatia","institution_ids":["https://openalex.org/I51314090"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080657434","display_name":"Nikolina Zovko","orcid":null},"institutions":[{"id":"https://openalex.org/I4210133956","display_name":"Agricultural Institute Osijek","ror":"https://ror.org/02qdg4b08","country_code":"HR","type":"facility","lineage":["https://openalex.org/I4210133956"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Nikolina Zovko","raw_affiliation_strings":["JET do.o, Osijek, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"JET do.o, Osijek, Croatia","institution_ids":["https://openalex.org/I4210133956"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064789036","display_name":"Goran Kne\u017eevi\u0107","orcid":"https://orcid.org/0000-0003-4077-2737"},"institutions":[{"id":"https://openalex.org/I51314090","display_name":"University of Osijek","ror":"https://ror.org/05sw4wc49","country_code":"HR","type":"education","lineage":["https://openalex.org/I51314090"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Goran Knezevic","raw_affiliation_strings":["Faculty of Electrical Engineering, Computer Science and Information Technology University of Osijek, Osijek, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Computer Science and Information Technology University of Osijek, Osijek, Croatia","institution_ids":["https://openalex.org/I51314090"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068892875","display_name":"Jurica Perko","orcid":"https://orcid.org/0000-0003-1739-4360"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jurica Perko","raw_affiliation_strings":["Regional Energy Agency North Koprivnica, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Regional Energy Agency North Koprivnica, Croatia","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064466237","display_name":"Rebeka Raff","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Rebeka Raff","raw_affiliation_strings":["Public Institute County Development Agency Osijek, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Public Institute County Development Agency Osijek, Croatia","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072505291","display_name":"Velimir Golub","orcid":"https://orcid.org/0000-0002-7796-3054"},"institutions":[{"id":"https://openalex.org/I4210133956","display_name":"Agricultural Institute Osijek","ror":"https://ror.org/02qdg4b08","country_code":"HR","type":"facility","lineage":["https://openalex.org/I4210133956"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Velimir Golub","raw_affiliation_strings":["Vodovod d.o.o Osijek, Croatia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Vodovod d.o.o Osijek, Croatia","institution_ids":["https://openalex.org/I4210133956"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.10169405,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"6","issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.587883710861206},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5840376615524292},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5302887558937073},{"id":"https://openalex.org/keywords/grid-connected-photovoltaic-power-system","display_name":"Grid-connected photovoltaic power system","score":0.5151599645614624},{"id":"https://openalex.org/keywords/distribution-grid","display_name":"Distribution grid","score":0.5009260177612305},{"id":"https://openalex.org/keywords/distribution","display_name":"Distribution (mathematics)","score":0.4915834367275238},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.44432222843170166},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.43139469623565674},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3875581622123718},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3838618993759155},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3736378848552704},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.3604281544685364},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.34535038471221924},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31851351261138916},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12059912085533142},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.117389976978302}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.587883710861206},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5840376615524292},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5302887558937073},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.5151599645614624},{"id":"https://openalex.org/C2986219281","wikidata":"https://www.wikidata.org/wiki/Q844861","display_name":"Distribution grid","level":3,"score":0.5009260177612305},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.4915834367275238},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.44432222843170166},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.43139469623565674},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3875581622123718},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3838618993759155},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3736378848552704},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.3604281544685364},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.34535038471221924},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31851351261138916},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12059912085533142},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.117389976978302},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eurocon.2019.8861810","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eurocon.2019.8861810","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE EUROCON 2019 -18th International Conference on Smart Technologies","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8100000023841858,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1925251778","https://openalex.org/W2019329524","https://openalex.org/W2211847817","https://openalex.org/W2283526601","https://openalex.org/W2521086296","https://openalex.org/W2796213988"],"related_works":["https://openalex.org/W2090575600","https://openalex.org/W2366001104","https://openalex.org/W2366644717","https://openalex.org/W2367445858","https://openalex.org/W2351307261","https://openalex.org/W2026423993","https://openalex.org/W2381993707","https://openalex.org/W2093748482","https://openalex.org/W2718866681","https://openalex.org/W2095582430"],"abstract_inverted_index":{"In":[0,46],"this":[1],"paper":[2],"case":[3],"study":[4],"on":[5,13],"influence":[6],"of":[7,10,51],"high":[8],"share":[9],"PV":[11,31,41],"systems":[12],"distribution":[14,27,53],"network":[15,54],"is":[16],"presented.":[17],"Six":[18],"different":[19],"simulation":[20],"scenarios":[21,37],"are":[22,44],"obtained.":[23],"Basic":[24],"scenario":[25,48],"presents":[26],"grid":[28],"with":[29],"no":[30],"power":[32,42,56],"plants":[33,43],"installed.":[34,45],"Other":[35],"five":[36],"present":[38],"cases":[39],"when":[40],"each":[47],"voltage":[49],"profile":[50],"the":[52],"and":[55],"losses":[57],"will":[58],"be":[59],"observed.":[60]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}